My Account  |  0 item(s)    View Cart
Home > Vehicle Detectors > Diablo Controls Loop Detectors
Diablo Controls DML- 9LP Probe Kit Vehicle Loop Detector - 75'
Diablo Controls DML- 9LP Probe Kit Vehicle Loop Detector
Email a friend Email a friend
Add to Wish List Add to Wish List
Share |

Diablo Controls DML- 9LP Probe Kit Vehicle Loop Detector - 75'

Item Id: Diablo-DSP-9LP
Review this item Review this item
Your Price: $149.95
Quantity
Description

Features

  • Designed for solar powered applications.
  • Designed to be cross talk free between other loops.
  • Automatically compensates for loop and lead-In sizes.
  • Switchless, self-adapting to most common installations.
  • Plug and play; Connect it up and watch it work.
  • Small profile, perfect for many installations.
  • Fail secure operation.
  • Wide low-voltage operation.
  • This series of Diablo Controls detectors are covered by United States patent.
    1. Patent number US 7,132,959.
    2. Non-Interfering Vehicle.
    3. Detection.

Overview
Detector operates on any voltage from 10 to 30 volts AC or DC and  draws about 1 milliamp of current with no vehicle on the loop. This  micro-sized detector is connected to Diablo Control s new mini-loop and uses a  completely new technology other than the standard inductive loops. Imagine, no more loop size or lead-in length issues.

LED Indicators
The green Power LED blinks once per second to indicate the detector is operating  and powered. The red Detect LED will turn on when a vehicle is over the loop detection area.

Loop or Wire Failures
In the case of a loop circuit failure, the green LED flashes slowly (twice per second) for an open loop circuit failure. The green LED will flash fast (10 times per second) to indicate a shorted loop circuit.

Pulse Operation
This detector only outputs a single 125 ms pulse when the vehicle passes over the detection area. There is no option to operate in the presence mode.

Fail Safe vs Fail Secure
A fail safe detector will output detect when the loop circuit is failed. On the free exit loop this will keep the gate open until the situation is fixed. This is useful in applications where it is important to allow traffic flow to continue. A fail secure detector will never output detect when the loop circuit is failed. This will keep the gate closed. This is useful in high-security areas or installations where containment is needed. The DML-9LP is a fail secure detector. Note: Never use a fail secure detector on a safety loop.

Power
This detector is powered with 10 to 30 volts AC or DC. Approximately 1 mA current. The relay contacts are rated at 1 amp maximum.

Connector
Removable 7-pin terminal block.
Pin assignments are shown below (from left to right):
1 Relay Normally Closed (NC) - contact opens for detect
2 Relay Common
3 Relay Normally Open (NO) - contact closes for detect
4 Power Common
5 Power In (10 to 30 volts AC or +DC)
6 Mini-Loop
7 Mini-Loop

Size
Height: 1.52" Width: 2.9" Depth: 1.56"

Operating Temperature
-35°F to 165°F (-37°C to 74°C