Product Overview
The EDI LMA-100-LV is a single-channel inductive loop vehicle detector used in professional gate, parking, and access-control installations. It connects to a saw-cut or preformed inductive loop in the pavement and monitors changes in loop inductance caused by a vehicle in the detection area. When a vehicle is detected, the detector changes its relay output so the gate operator, barrier gate controller, telephone entry system, or access-control panel can respond according to the way that loop input is programmed. This type of detector is commonly used for free-exit loops, safety/reverse loops, presence loops, hold-open loops, arming loops, and parking control lanes.
This LMA-100 model is the LMA-100-LV version, with single detect output relay and 12 VDC, 24 VDC, or 24 VAC nominal low-voltage systems. The correct detector is not chosen by brand alone. The installer should match the original detector part number, input voltage, 11-pin socket wiring, relay output requirements, and desired fail-safe or fail-secure behavior. A low-voltage detector should not be placed into a high-voltage socket, and a fail-secure detector should not be substituted for a fail-safe detector unless the system design specifically calls for that behavior.
EDI detectors are commonly selected because they provide practical setup and troubleshooting features for field technicians. Depending on the series, features may include adjustable sensitivity, selectable loop frequency, sensitivity boost, loop fault monitoring, stored fault memory, output delay or extension, and LED indication for power, detect, and fault conditions. Those features help identify common loop problems such as open loops, shorted loops, large inductance changes, crosstalk between nearby loops, incorrect sensitivity settings, or a detector that is being powered from the wrong source.
Compatible With
This detector may be used with compatible vehicle loop systems when the power, socket wiring, output contacts, fail-safe/fail-secure behavior, and controller input requirements match the installation.
- EDI LMA-100 Series low-voltage detector sockets
- 11-pin Molex / Amphenol style loop detector sockets wired for low-voltage input
- gate operators and access-control systems that require one dry-contact loop relay
- swing gate and slide gate safety or exit loops
- barrier gate, parking arm, and access-control loop circuits using one presence output
- vehicle detection loops within the detector's 20 to 2500 microhenry tuning range
Features and Specifications
| Manufacturer | EDI Traffic / Eberle Design Inc. |
|---|
| Product Type | single-channel inductive loop vehicle detector |
|---|
| Part Number | LMA-100-LV |
|---|
| Series | LMA-100 |
|---|
| Application | Vehicle detection for gate, parking, and access-control systems that need a dependable single-channel detector with one output relay for safety, exit, hold-open, or presence detection. |
|---|
| Channels | Single channel |
|---|
| Relay Output | Single detect output relay |
|---|
| Voltage | 10 to 40 VDC or 14 to 35 VAC low-voltage input range |
|---|
| Fail Behavior | Fail-safe version |
|---|
| Connector | 11-pin Molex / Amphenol style detector connector |
|---|
| Loop Inductance Range | 20 to 2500 microhenries on supported loop installations |
|---|
| Setup / Diagnostics | Adjustable sensitivity, loop fault monitoring, fault memory, and frequency control depending on series |
|---|
| Notes | Match voltage, socket pinout, output function, and fail mode before replacing an existing detector |
|---|
Also Known As / Related Part Numbers
Common search references and related EDI detector family numbers include:
- LMA-100-LV
- LMA100LV
- LMA 100 LV
- LMA-100
- EDI LMA-100
- EDI LMA100
- Eberle Design LMA-100-LV
- LMA-100 low voltage
- LMA-100 fail safe
- LMA-100 single output
- LMA-100-HV - related family reference; verify exact interchange before ordering
- LMA-100S-LV - related family reference; verify exact interchange before ordering
- LMA-100S-HV - related family reference; verify exact interchange before ordering
- LMA-200-LV - related family reference; verify exact interchange before ordering
- LMA-200-HV - related family reference; verify exact interchange before ordering
Technician Note
The LMA-100 is a more basic single-output detector than the dual-output LMA-200 and LMA-1250 series. Use the low-voltage model only when the detector socket supplies 12/24VDC or 24VAC style power. Good choice when the controller only needs one loop relay and the original installation used the LMA-100 pinout.
Before Ordering
- Confirm the exact model number printed on the original detector.
- Confirm low-voltage or high-voltage detector input power at the socket.
- Confirm fail-safe or fail-secure operation required by the gate or parking system.
- Confirm whether the installation needs one relay output or dual relay outputs.
- Inspect the loop wiring for open circuits, shorts, water intrusion, damaged lead-in wire, or incorrect loop inductance.
- Confirm the 11-pin socket wiring and operator manual before applying power.
Professional Advisory
Loop detector wiring can affect gate safety, vehicle detection, and automatic gate behavior. Do not bypass monitored safety devices or use a detector to defeat required entrapment protection. If the gate moves unexpectedly, the loop circuit is damaged, or the detector socket voltage is not confirmed, have the system checked by a qualified gate or access-control technician.
Product Questions and Answers
What type of loop detector is the EDI LMA-100-LV?
The EDI LMA-100-LV is a single-channel inductive loop vehicle detector used with a buried inductive loop to detect vehicles for gate, parking, and access-control equipment.
What voltage should be used with the EDI LMA-100-LV?
The EDI LMA-100-LV should be powered from a matching detector socket. This model is specified for 10 to 40 VDC or 14 to 35 VAC low-voltage input range.
Is the EDI LMA-100-LV a fail-safe or fail-secure detector?
The EDI LMA-100-LV is a fail-safe version. Match this behavior to the original detector and the gate operator wiring before replacing the module.
Can the EDI LMA-100-LV be used for exit and safety loops?
The EDI LMA-100-LV may be used for exit, safety, reverse, hold-open, arming, or presence loop functions when the gate operator or access-control panel supports the detector output and the loop is wired correctly.
What should be checked before ordering the EDI LMA-100-LV?
Check the original part number, input voltage, fail-safe or fail-secure behavior, relay output requirements, 11-pin socket wiring, and the gate operator's loop detector instructions.