Up Limit Output
Contacts activate when door reaches up limit. N-O, and N-C contacts included. Two sets of single-pole double-throw (SPDT) contacts.
Down Limit Output
Contacts activate when door reaches down limit. N-O, and N-C contacts included. Two sets of single-pole double-throw (SPDT) contacts.
Mid-Stop Limit Output
Contacts activate when door reaches mid-stop. N-O, and N-C contacts included. One set of single-pole double-throw (SPDT) contacts.
ADA Output
Contacts confi gurable via LCD to activate when door is moving open, closed, or both open and closed. One set of single-pole double-throw (SPDT) contacts.
Lamp Output
Contacts activate when door is set into movement and has a five-minute delay before turning off. One set of single-pole double-throw (SPDT) contacts.
Plug and Play
Plugs directly into control board expansion port, and can daisy chain with additional expansion modules.
Set-Up
LCD display is used to adjust ADA output.