Front Panel Selections Sensitivity controlled by front panel DIP switch. 0 = Low sensitivity 1 = Med Low 2 = Med High 3 = High sensitivity Medium Low sensitivity is used for most applications; this is a setting of 1. Always use the lowest sensitivity setting that detects the desired vehicles. Lower sensitivity allows operation with the lowest possible current consumption. Frequency four separate settings controlled by front panel. DIP switches. 2+1 = High 2+0 = Medium High 1+0 = Medium Low 0+0 = Low Reset front panel reset performs a hard reset of the detector. Internal Switch Settings: Call Delay select from delay off and 2 second delay Call Extend select from extend off and 5 second extend Permanent Presence select from 60 minute and permanent presence. Outputs: Detect Output is fail secure, loss of power does not cause a detect output to be placed. | Factory Settings Set to High frequency Set to Medium Low sensitivity (1) Specifications: Output Rating: Relay Output is rated 120VAC, 28VDC, 0.5A Supply Power: 10 30 V DC or AC, 1mA nominal Inductance Range: 20uH to 1000uH. Temperature Range: -30 F to +180 F. Lead-In Length: up to 1000 ft. with proper lead-in and loop. Mechanical: 2.4 H x 2.25 D x 0.8 W. Supply Voltage incorrect voltage supplied to the unit will not result in damage, the unit will simply not operate until correct voltage is supplied. No fuses need to be reset. Indicators front panel indicators: Power/Fault - Green, solid with correct power supplied. - Flashes during a fault condition. - Fault flash sequence: - Single flash & pause = Open Circuit Loop. - Double flash & pause = Shorted Loop. Detect - Red, solid during detect. Power Saving Mode: While in normal operation with no fault indication, the Green LED will extinguish after a period of 2 minutes. A power interruption or reset will re-illuminate the Green LED. Sensitivity Boost automatic during detect except in the highest sensitivity setting (3). Connector: 7 position Screw Terminal Block Pin # Function 1 Loop 2 Loop 3 Relay N.C. 4 Relay N.O. 5 Relay Common 6 Power 10 30 VDC or AC 7 Power Logic Ground Note: The above connections are shown with correct power supplied and no vehicle present. |