SECO-LARM SA-26Q Mini-Timer Module - Low-Voltage Miniature Delay Timer Module with Relay Output
The SECO-LARM SA-026Q is a miniature timer relay module built for low-voltage access-control and security circuits where a simple adjustable delay is needed. It is often used to stretch the output from a momentary push button, keypad relay, sensor, or access-control trigger so that a lock, relay, buzzer, or input stays active long enough for the door or gate function to complete. Its small size makes it useful in tight spaces such as an access-control enclosure, low-voltage junction box, or door hardware wiring area.
This timer is commonly selected when the site does not need the broader programming options of the SA-025Q or the calendar scheduling of the SA-027 timers. The SA-026Q is best suited for short relay timing jobs, especially electric strikes and maglock support circuits that lack their own delay. Correct polarity, operating voltage, relay contact choice, and load rating still matter. It should not be installed as a workaround for a missing listed access-control component or a required safety release device.
Compatible With
Compatible with many low-voltage access-control circuits, request-to-exit buttons, electric strike circuits, maglock control relays, door release inputs, gate operator command inputs, buzzers, annunciators, and small automation circuits that need a timed relay output. Verify the input trigger, 12-24 VAC/VDC power, relay contact rating, and timing range before using it as a replacement.
Features & Specifications
| Manufacturer | SECO-LARM / ENFORCER |
|---|
| Product Type | Mini programmable timer module |
|---|
| Part Number | SA-026Q |
|---|
| Application | Short adjustable timed relay output |
|---|
| Voltage | 12-24 VAC/VDC |
|---|
| Timing Range | Commonly listed as 1-180 seconds |
|---|
| Relay Output | Form C / SPDT terminal block references |
|---|
| Common Uses | Electric strikes, maglocks, RTE buttons, access-control relay circuits |
|---|
| Notes | Compact low-voltage control accessory |
|---|
Also Known As / Related Part Numbers
- SA-026Q
- SA026Q
- SA-026
- SA026
- ENFORCER SA-026Q
- SECO-LARM SA-026Q
- mini timer module
- low-voltage delay timer module
Technician Note
The SA-026Q is useful for short delay jobs, but it must be matched to the circuit. If the existing unit is an older SA-026, compare timing range, relay rating, and wiring terminals before replacing it with SA-026Q.
Before Ordering Checklist
- Confirm the existing part number and timing range.
- Verify the circuit uses 12-24 VAC/VDC.
- Confirm whether the controlled device needs NO or NC relay contacts.
- Check the lock or relay load against the module rating.
- Keep all emergency release and egress wiring code-compliant.
Professional Advisory
Access-control and gate wiring should be performed with the power disconnected and with the system wired according to the operator, lock, or access-control manual. Do not bypass required safety devices. For high-voltage circuits, delayed egress code requirements, or unsafe gate movement, use a qualified gate or access-control technician.
Product Questions
What does the SA-026Q do?
It extends or controls the activation time of a momentary low-voltage input using an adjustable timer relay.
Can it be used with an electric strike?
Yes, it is commonly used when an electric strike circuit needs a timed release period and the load is within rating.
Is this the same as the SA-025Q?
No. The SA-026Q is a smaller mini timer for simpler short timing functions, while the SA-025Q offers broader multi-purpose timer programming.
What voltage does it use?
It is commonly listed for 12-24 VAC/VDC low-voltage operation.
Can it replace a delayed egress timer?
No. Delayed egress applications require the correct delayed-egress hardware and code-compliant installation.