Select Entry Systems SG2CL Cellular Select Gate Entry System
The Select Entry Systems SG2CL is a Cellular Select Gate entry system designed for residential and light commercial gate access-control applications. It gives a property owner, manager, or authorized user several ways to control the gate without relying on a traditional landline at the gate location.
The SG2CL can be controlled by SMS text, the Select Gate Mobile Control app, keypad entry, remote touch tones, and compatible card readers connected through the built-in 26-bit Wiegand input. It is commonly used for driveway gates, private road entrances, gated properties, small commercial entries, service gates, employee entrances, and other controlled access points where a cellular gate entry system is preferred over a hardwired phone-line system.
This model is part of the Cellular Select Gate Series. It is the SG2CL version, also commonly described as the Select Gate 2 cellular entry control. It should be kept separate from standard non-cellular Select Gate models and from SG3DMCL or SG3DMRCL models, which use a different cabinet layout and may include or support different receiver options.
The SG2CL supports up to 10 phone numbers that can be dialed from the keypad, along with up to 1000 Caller ID recognizable phone numbers. It can forward calls to up to 3 rollover phone numbers in the programmed sequence, helping visitors reach the correct person if the first number does not answer.
For access credentials, the SG2CL supports 2000 mix-and-match PINs and cards depending on how the system is configured. PIN code range is listed from 0001 to 9999, card number range from 00001 to 65534, and site code range from 001 to 255. The built-in 26-bit Wiegand input allows a compatible card reader to be added when card or credential access is needed.
The SG2CL includes two Form C dry-contact relay outputs for gate or door control. These relays are used to send access commands to a compatible gate operator, door controller, or access-control input. The SG2CL does not power the gate operator and does not replace the gate operator control board. It sends the command; the gate operator still performs the actual open, close, and safety functions.
This system also supports useful gate-control commands such as latch open and hold open for 1 hour through SMS text, the mobile app, or remote touch tones. It includes a REX input, gate-position sense input, SMS signal-strength verification, LED lighting, and a blue backlit keypad for better visibility at night.
Cellular service must be planned before installation. The site needs reliable cellular signal at the exact mounting location, not just near the house, office, or driveway. The cellular device also requires an active SIM/service plan with the required voice and SMS services for normal operation. Always confirm the current carrier, SIM activation, coverage, and service-plan requirements before installation.
Important: The Cellular Select Gate is not an emergency telephone and cannot be used for 911 calls. Emergency access, fire department access, Knox-style access, manual release, monitored safety devices, loop detectors, photo eyes, and safety edges must be handled separately according to the gate system and local requirements.
What This Cellular Gate Entry System Does
- Provides cellular-based gate entry control without a traditional landline at the gate
- Allows gate control by SMS text, SGMC mobile app, keypad, remote touch tones, or compatible card reader
- Supports up to 10 phone numbers dialed from the keypad
- Recognizes up to 1000 Caller ID phone numbers for authorized access
- Supports call forwarding to up to 3 rollover phone numbers in sequence
- Supports up to 2000 mix-and-match PINs and cards depending on setup
- Includes a built-in 26-bit Wiegand input for compatible card-reader access
- Includes two Form C dry-contact relay outputs for compatible gate or door control inputs
- Supports latch-open and 1-hour hold-open commands through SMS text, mobile app, or remote touch tones
- Includes REX input and gate-position sense input
- Provides signal-strength verification by SMS text
- Includes LED lighting and a blue backlit keypad for nighttime visibility
Common Use Cases
- Residential driveway gate telephone entry and keypad access
- Private road gate access control
- Small commercial gate entry systems
- Employee or service gate access
- Gated properties where a phone line is not available at the gate
- Small HOA or shared driveway applications with limited phone-number needs
- Gate systems needing Caller ID access for authorized phone numbers
- Gate systems needing keypad PIN access and optional card-reader access
- Replacing an older telephone entry unit where cellular service is preferred
- Applications where SMS text and mobile app control are useful for gate operation
Compatible With
The Select Entry Systems SG2CL can be used with many gate operators and access-control devices that accept a compatible dry-contact relay command. Final compatibility depends on the gate operator wiring diagram, relay input requirements, power source, cellular service, Wiegand reader requirements, and site layout.
- Residential swing gate operators with compatible open, radio, push-button, or access-control inputs
- Residential slide gate operators with compatible open, radio, push-button, or access-control inputs
- Light commercial swing gate operators with compatible dry-contact access-control inputs
- Light commercial slide gate operators with compatible dry-contact access-control inputs
- Select barrier gate operators where relay-based entry control is appropriate
- Pedestrian gate or door controllers where the relay rating and wiring are appropriate
- Compatible 26-bit Wiegand card readers
- Compatible proximity card reader systems where card number and site code ranges match
- Select Gate Mobile Control app / SGMC app applications
- Sites with reliable cellular coverage and an active compatible SIM/service plan
- Surface-mount installations
- Pedestal-mount installations where vehicle approach height and mounting pattern are correct
Important: The SG2CL does not replace the gate operator, receiver, loop detector, photo eye, safety edge, or gate control board. It is an entry-control device that sends commands to a compatible gate or door system.
Not Intended For
- Emergency phone or 911 calling applications
- Large multi-tenant directory systems that require a large resident directory
- Touchscreen visitor directory applications
- Cloud-managed access systems that require large-scale web administration
- Applications requiring more phone-number capacity than the SG2CL supports
- Sites with poor cellular coverage at the gate location
- Replacing a gate operator control board, receiver, loop detector, photo eye, or safety edge
- Vehicle detection, free-exit, or gate safety applications
- Powering a gate operator, maglock, or electric strike directly beyond relay specifications
- Installations where required safety devices or emergency access equipment are missing
Important Ordering Warnings
- Confirm the manufacturer model is SG2CL.
- Confirm your store SKU or item number, such as SES-SG2CL, matches this Cellular Select Gate model.
- Confirm whether the customer needs SG2CL, SG3DMCL, SG3DMRCL, or a non-cellular Select Gate model.
- Confirm the installation has reliable cellular coverage at the exact mounting location.
- Confirm the cellular SIM and service plan requirements before installation.
- Confirm the unit is being used for gate entry, not emergency 911 calling.
- Confirm the connected gate operator or controller accepts a dry-contact relay command.
- Confirm whether Relay 1, Relay 2, latch-open, and 1-hour hold-open functions are needed.
- Confirm whether a compatible 26-bit Wiegand reader will be connected.
- Confirm the required PIN/card capacity, site code range, and card number range.
- Confirm current power requirements. Current product-sheet wording lists 12-24V DC only with a 12V 2A DC transformer included.
- Confirm pedestal or surface mounting before running conduit and wiring.
- Confirm REX input, gate-position sense input, emergency access, fire access, safety loops, photo eyes, and monitored entrapment protection are handled separately by the gate system.
Features & Specifications
| Feature / Specification | Details |
| Manufacturer | Select Entry Systems / Select Engineered Systems |
| Product Family | Cellular Select Gate Series |
| Product Type | Cellular gate entry and telephone access-control system |
| Manufacturer Model | SG2CL |
| Common Store SKU | SES-SG2CL |
| Network Reference | 4G / LTE / VoLTE cellular service, depending on current unit and active carrier plan |
| Control Methods | SMS text, SGMC mobile app, keypad, remote touch tones, and compatible card readers |
| Mobile App | Select Gate Mobile Control app / SGMC app |
| Dialed Phone Number Capacity | 10 phone numbers dialed from keypad |
| Caller ID Capacity | 1000 Caller ID recognizable phone numbers |
| Rollover Calling | Call forward to up to 3 rollover phone numbers in programmed sequence |
| PIN / Card Capacity | 2000 mix-and-match PINs and cards depending on setup |
| PIN Code Range | 0001 to 9999 |
| Card Number Range | 00001 to 65534 |
| Site Code Range | 001 to 255 |
| Wiegand Input | Built-in 26-bit Wiegand input for compatible card access |
| Relay Outputs | 2 Form C dry-contact relay outputs |
| Relay Rating | 24V at 3 amps, based on current product-sheet specification |
| Gate Commands | Open/close, latch open, and hold open 1 hour where programmed |
| REX Input | Request-to-exit input included |
| Gate Position Input | Gate-position sense input included |
| Signal Check | Signal-strength verification by SMS text |
| Lighting | LED lighting and blue backlit keypad |
| Mounting Dimensions | 7 in H x 9 7/16 in W x 4 9/16 in D |
| Construction | 0.090 aluminum back box, primed and painted black texture for exterior use; stainless-steel faceplate |
| Power Input | 12-24V DC only, based on current product-sheet specification |
| Included Transformer / Power Supply | 12V 2A DC transformer included, based on current product-sheet specification |
| Current Draw | 90mA at 12VDC; 80mA at 24VDC |
| Operating Environment | -20 degrees F to +140 degrees F; 5% to 95% relative humidity, non-condensing |
| Mounting | Surface or pedestal mount |
| Memory Type | Non-volatile memory |
| Tone Detection | Crystal-controlled detection of 100 ms DTMF tones; detects touch tones only |
| Shipping Weight | Approx. 15 lb for SG2CL only; actual shipping weight depends on final system configuration |
| Emergency Calling Note | This cellular device cannot be used for 911 calls |
Also Known As / Related Part Numbers
- Select Entry Systems SG2CL
- Select Engineered Systems SG2CL
- SES SG2CL
- SG2CL
- SES-SG2CL
- Select Gate 2 cellular
- Select Gate 2 cellular entry system
- Cellular Select Gate SG2CL
- Cellular Select Gate entry system P/N SG2CL
- 4G / VoLTE Cellular Select Gate
- Cellular Select Gate Series
- SGMC mobile app, related Select Gate Mobile Control app
- SG3DMCL, related Cellular Select Gate model with different cabinet layout
- SG3DMRCL, related Cellular Select Gate model with optional receiver configuration
- SG2C, related non-cellular Select Gate 2 model
- SG2, related legacy Select Gate 2 reference
Related Parts and Accessories
- Compatible 26-bit Wiegand card reader
- Compatible access-control cards or credentials where card number and site code match
- Compatible gooseneck pedestal or mounting post
- Compatible low-voltage access-control cable and conduit
- Compatible gate operator relay input wiring
- Compatible REX device where request-to-exit input is needed
- Compatible gate-position switch where gate-position sense is used
- Compatible cellular SIM/service plan required for operation
- Compatible emergency access, fire department access, manual release, or Knox-style access equipment where required
- Compatible gate safety devices, loop detectors, monitored photo eyes, safety edges, and warning devices required by the gate operator installation
Related item note: SIM activation, cellular service plan, pedestal, card reader, cards, gate operator, lock controller, conduit, wiring, safety devices, emergency access equipment, and installation labor are separate unless the product listing specifically states that they are included.
Technician Note
The SG2CL is a cellular gate entry system, not a large multi-tenant directory system. It is a good choice when the job needs keypad access, phone-number calling, Caller ID access, SMS text control, app control, remote touch-tone control, and optional 26-bit Wiegand card-reader access in a compact Select Gate package.
Before selling this unit, confirm cellular signal at the exact gate location. Signal at the office, house, parking area, or technician phone does not always mean the mounted call box location has reliable service. Metal posts, masonry columns, long driveways, landscaping, and weak carrier coverage can affect performance.
Power wording should be reviewed carefully. Older listings may show 12-24V AC/DC or reference an AC transformer. Current product-sheet wording for SG2CL lists 12-24V DC only with a 12V 2A DC transformer included. Verify the current unit and installation manual before wiring or publishing specifications.
The SG2CL includes two Form C dry-contact relay outputs. Wire those relays only to compatible low-voltage access-control inputs on the gate operator or door controller. Do not use the relays to switch high-voltage operator power or bypass the gate operator control board.
This device cannot be used for 911 calls. It should not be sold as an emergency phone, fire department phone, elevator phone, or life-safety phone. Emergency access and fire access must be handled separately according to the property, local authority, and gate system requirements.
Before Ordering, Confirm
- The required model is SG2CL.
- The store part number is SES-SG2CL or the matching internal SKU used for this product.
- The customer needs the SG2CL Cellular Select Gate, not SG3DMCL, SG3DMRCL, SG2C, or another Select Gate model.
- The site has reliable cellular signal at the exact mounting location.
- The SIM card and cellular service plan requirements are understood before installation.
- The connected gate operator or door controller accepts a dry-contact relay input.
- The customer needs no more than 10 dialed keypad phone numbers.
- The customer needs no more than 1000 Caller ID recognizable phone numbers.
- The PIN/card capacity and numbering requirements match the site.
- Any card reader being added is compatible with the built-in 26-bit Wiegand input.
- The mounting method is selected, such as surface mount or pedestal mount.
- The power source matches the current 12-24V DC requirement.
- The customer understands the device cannot be used for 911 calls.
- The gate operator safety devices, emergency access, fire access, and manual release equipment are handled separately.
Professional Advisory
The Select Entry Systems SG2CL should be installed by a qualified gate, access-control, or low-voltage technician when relay wiring, DC power wiring, Wiegand reader wiring, cellular activation, programming, or gate operator input wiring is not clearly understood.
Do not use the SG2CL to bypass gate safety devices, monitored photo eyes, safety edges, loop detectors, stop circuits, emergency access devices, or required entrapment protection. The SG2CL provides access-control commands only. The gate operator must still be installed, wired, and tested as a safe automatic gate system.
After installation, test every access method being used. Confirm keypad dialing, rollover numbers, SMS commands, SGMC app control, touch-tone control, Caller ID access, PINs, card-reader access, relay operation, REX input, gate-position sense, cellular signal, emergency access, and all gate safety-device operation before turning the system over to the customer.
Product Q&A
What is the Select Entry Systems SG2CL?
The SG2CL is a Cellular Select Gate entry system that provides gate access by SMS text, SGMC mobile app, keypad, remote touch tones, Caller ID, and compatible 26-bit Wiegand card readers.
Does the SG2CL require a phone line?
No. The SG2CL is a cellular entry system, so it does not require a traditional landline at the gate. It does require reliable cellular signal and an active SIM/service plan with the services needed for operation.
How many phone numbers can be dialed from the SG2CL keypad?
The SG2CL supports up to 10 phone numbers that can be dialed from the keypad.
Does the SG2CL support Caller ID access?
Yes. The SG2CL supports up to 1000 Caller ID recognizable phone numbers for authorized access where programmed correctly.
Can the SG2CL work with card readers?
Yes. The SG2CL includes a built-in 26-bit Wiegand input for compatible card-reader access. The reader, card format, site code, card number range, and programming must match the system.
How many relays does the SG2CL have?
The SG2CL includes two Form C dry-contact relay outputs for compatible gate or door control inputs.
Can the SG2CL be used for 911 calls?
No. The SG2CL cellular device cannot be used for 911 calls. It should not be used as an emergency phone or life-safety communication device.
What power does the SG2CL require?
Current product-sheet wording lists the SG2CL as 12-24V DC only with a 12V 2A DC transformer included. Verify the current unit documentation before wiring.
What should be checked before installing the SG2CL?
Check cellular coverage, SIM/service plan, DC power, relay wiring, Wiegand reader compatibility, keypad phone numbers, Caller ID list, mounting method, emergency access, and the gate safety system before completing the installation.