GTO PRO-SW3200XLS Secondary Operator Compatibility With SW3000XLS Systems
The GTO PRO-SW3200XLS is the secondary swing gate operator used with a compatible PRO-SW3000XLS primary operator. Adding the SW3200XLS converts a properly configured SW3000XLS single-gate installation into a dual swing gate system.
The secondary operator controls the second gate leaf but does not operate independently. It receives power and operating commands from the primary SW3000XLS control box through the included 40-foot power cable.
Compatible With
- GTO PRO-SW3000XLS primary swing gate operator
- Linear Pro Access PRO-SW3000XLS primary swing gate operator
- Nice Linear PRO-SW3000XLS primary operator systems
- Dual residential vehicular swing gates within the published SW3000XLS capacity
- Pull-to-open installations using the standard operator mounting arrangement
- Push-to-open installations using the required R4388 push-to-open brackets and correct control-board setup
Important Product Naming Warning
PRO-SW3000XLS is the primary operator model. PRO-SW3200XLS is the complete secondary operator kit used for the second gate leaf. Product descriptions may refer to the completed installation as an SW3000XLS/3200XLS dual gate system.
Do not confuse the complete PRO-SW3200XLS secondary operator kit with a replacement secondary arm sold under numbers such as PRO3200ARMXLS. An arm-only product may not include the brackets, stop plate, warning signs, or complete installation hardware supplied with the secondary operator kit.
What the Secondary Operator Does
- Automates the second leaf of a compatible dual swing gate
- Connects to the primary SW3000XLS control system
- Receives 12V DC power and control signals through the secondary cable
- Works with the primary control board's gate sequencing settings
- Supports soft-start and soft-stop operation
- Works with adjustable obstruction sensing and automatic closing functions
- Supports transformer-charged or properly sized solar installations through the primary system
- Can be configured for pull-to-open or push-to-open operation with the correct hardware
Manufacturer-Listed Secondary Kit Contents
- PRO-SW3200XLS second gate operator arm
- 40-foot power cable
- Two warning signs
- Gate bracket
- Post bracket
- Post pivot bracket
- Closed-position stop plate
- Mounting bolts, washers, lock washers, nuts, clevis pins, bushings, hairpin clips, screws, and cable ties
Package contents can change or may differ when the product is sold as an arm-only replacement. Confirm the seller's current packing list before ordering.
Features and Specifications
| Specification |
Details |
| Brand |
GTO / Linear Pro Access / Nice Linear |
| Part Number |
PRO-SW3200XLS |
| Product Type |
Secondary linear swing gate operator kit |
| Required Primary Operator |
PRO-SW3000XLS |
| Gate Configuration |
Dual vehicular swing gate |
| Maximum Gate Length |
Up to 16 feet per gate leaf |
| Maximum Gate Weight |
Up to 650 pounds per gate leaf |
| Operating Voltage |
12V DC through the compatible primary system |
| Drive Type |
Linear screw-drive actuator with planetary gear reduction |
| Approximate Gate Speed |
Approximately 15 to 18 seconds depending on gate and installation conditions |
| Maximum Arm Stroke |
Approximately 16 inches |
| Retracted Mounting Length |
Approximately 40.25 inches between mounting points |
| Maximum Opening Arc |
Up to approximately 110 degrees when mounting geometry permits |
| Operating Temperature |
Approximately -5 F to 160 F |
| Secondary Cable |
40-foot power and control cable |
| Opening Direction |
Pull-to-open standard; push-to-open with required brackets and programming |
| Solar Compatibility |
Solar compatible through a correctly sized SW3000XLS primary system |
| Primary Control Box Included |
No |
| Transformer and Receiver Included |
No - these are part of the primary system |
| Application |
Vehicular swing gates only |
Gate Size and Wind-Load Warning
The published capacity is up to 16 feet and 650 pounds per gate leaf. The gate must also be properly constructed, supported, balanced, and able to swing freely throughout its complete travel.
Solid wood, privacy-panel, sheet-metal, and other solid-surface gates create significant wind resistance. The manufacturer does not recommend this operator family for solid gates because wind loading can cause obstruction faults, stopping, reversal, blown fuses, accelerated wear, or structural damage.
Gate length and weight ratings do not override wind-load limitations, poor hinge condition, weak posts, incorrect mounting geometry, or excessive gate resistance.
Pull-to-Open and Push-to-Open Installations
The SW3000XLS and SW3200XLS system is normally configured as pull-to-open, where the operator retracts to open the gate toward the property.
A push-to-open installation requires the correct R4388 bracket for each operator and matching control-board programming. A complete dual push-to-open installation normally requires two R4388 brackets. Confirm post clearance, gate geometry, travel limits, and physical stops before ordering.
Comparison With Similar GTO and Linear Products
| Part or Model |
Application |
| PRO-SW3000XLS |
Primary operator with the control box, battery system, transformer, receiver, and primary actuator |
| PRO-SW3200XLS |
Complete secondary operator kit used to add the second gate leaf to an SW3000XLS system |
| PRO3200ARMXLS |
Replacement secondary actuator arm, commonly supplied with a 40-foot cable; not automatically the complete secondary installation kit |
| PRO-SW3200XL |
Earlier XL-generation secondary operator that should not be substituted without checking the control board, rev counter, cable, connectors, and mounting hardware |
| PRO-SW4200XLS |
Larger secondary operator intended for a compatible PRO-SW4000XLS primary system |
| Mighty Mule Secondary Arms |
Different operator families that are not automatically interchangeable with the PRO-SW3200XLS |
Also Known As and Related Part Numbers
- GTO SW3200XLS
- GTO PRO-SW3200XLS
- Linear PRO-SW3200XLS
- Linear Pro Access SW3200XLS
- Nice Linear PRO-SW3200XLS
- SW3000XLS second operator
- SW3000XLS secondary gate arm kit
- SW3000XLS/3200XLS dual gate system
- PRO3200ARMXLS - related replacement secondary arm only
- R4388 - related push-to-open bracket
- HB301 - related bracket box designation
- H301P - related mounting hardware bag designation
Not Intended For
- Stand-alone operation without a compatible primary control system
- PRO-SW2000XLS or PRO-SW4000XLS primary systems
- Older XL systems without confirmed XLS conversion compatibility
- Unrelated GTO, Mighty Mule, LiftMaster, Nice Apollo, or Linear actuators
- Pedestrian gates or pedestrian traffic paths
- Gates that drag, bind, sag, twist, or require the operator to support their weight
- Solid-surface gates exposed to significant wind loading
- Applications without the required entrapment-protection devices
Secondary Gate Troubleshooting Checks
A second gate leaf that does not move does not automatically need a replacement operator. Check the 40-foot secondary cable, underground conduit, cable splices, primary control-board output, battery voltage, operator connectors, rev-counter wiring, gate sequencing, limits, and mechanical gate movement before replacing the arm.
If the second leaf moves late, stops early, travels in the wrong direction, or does not close completely, inspect the control-board settings, operator wiring, gate geometry, limit programming, closed-position stop, and automatic gate lock sequencing.
Technician Note
Disconnect both operators from the gates and move each gate leaf manually before diagnosing the electrical system. Both leaves should swing freely without dragging, binding, or excessive hinge resistance. A mechanically difficult gate can overload the actuator and cause obstruction faults that appear to be electrical failures.
When replacing an operator on an existing system, compare the original model label, cable, rev-counter arrangement, front mount, scraper seal, connectors, and brackets. Similar-looking XL and XLS arms should not be assumed interchangeable.
Before Ordering Checklist
- Confirm that the existing primary operator is labeled PRO-SW3000XLS.
- Verify that a complete secondary operator kit is required rather than an arm-only replacement.
- Confirm that the existing system is XLS and not an earlier XL generation.
- Measure each gate leaf and verify that it is no longer than 16 feet and no heavier than 650 pounds.
- Confirm that the gate is not a high-wind solid-surface design.
- Check that each gate leaf swings freely and is properly supported by its hinges.
- Inspect the 40-foot cable route, conduit, splices, and terminal connections.
- Determine whether the gate is pull-to-open or push-to-open.
- Order the required R4388 brackets for a push-to-open installation.
- Confirm the included brackets, stop plate, warning signs, cable, and mounting hardware.
- Verify the required photo eyes, safety edges, physical stops, and emergency access equipment.
Installation and Service Notes
The primary control box must be mounted on the primary side, and the secondary cable must be routed through suitable conduit or another protected path to the second operator. Avoid unprotected underground splices, sharp bends, damaged insulation, and locations where water can collect.
Correct bracket geometry is critical. Improper mounting can cause binding, insufficient travel, actuator over-extension, damaged mounts, incorrect limits, or excessive force on the gate and posts.
Dual-gate sequencing must be adjusted so the gate leaves do not strike each other. Systems using an automatic gate lock may require an opening or closing delay between the two leaves.
Automatic gate operators are intended for vehicular traffic. Provide a separate pedestrian entrance. Do not bypass photo eyes, safety edges, obstruction sensing, warning signs, fire access, emergency access, or other operator safety circuits.
Professional Advisory
Installation, underground cable routing, bracket positioning, control-board wiring, gate sequencing, limit setup, force adjustment, and safety-device testing should be completed by a qualified gate technician familiar with GTO and Linear XLS operator systems.
Local pickup in Hialeah Gardens, Florida may be available after current inventory and package contents are confirmed.
Product Questions & Answers
Is this a complete gate opener system?
No. This is the secondary operator used with a compatible PRO-SW3000XLS primary operator. It is not a stand-alone complete opener by itself.
What primary opener does the PRO-SW3200XLS work with?
The PRO-SW3200XLS is commonly paired with the PRO-SW3000XLS primary/master operator in 3000XLS dual swing gate systems.
Can I use this with an older 3000XL system?
Do not assume compatibility. XL and XLS equipment may use different controls and sensing components, so verify the exact model generation first.
What symptoms point to a secondary arm issue?
A second leaf that does not move, moves intermittently, stops short, or reverses may have an arm, cable, limit, battery, board output, or gate drag issue.
Does each gate leaf need to be within the rating?
Yes. Each leaf should be within the published 3000XLS rating and must move freely before the operator is installed or replaced.