HySecurity MX002006 Limit Switch Kit For SwingSmart DC Gate Operator Openers
The HySecurity MX002006 limit switch kit is used on SwingSmart DC operators to restore the mechanical/electrical limit feedback used for gate travel reference. These switches help the operator determine where the gate should stop in the open and closed directions, which makes them important for proper setup and predictable movement.
A worn or misadjusted limit switch can cause the gate to stop too soon, overtravel, fail to complete a cycle, or show travel-related errors. In some cases, the issue is not the switch itself but the actuator adjustment, wiring, switch bracket position, controller setup, or a gate that has moved out of mechanical alignment.
This kit includes the two replacement limit switches and mounting screws commonly needed for service. After installation, the operator should be adjusted and tested according to the SwingSmart DC procedure so the gate stops correctly and all safety devices are operating properly.
Compatible With
- HySecurity SwingSmart DC swing gate operators
- SwingSmart DC limit switch replacement applications
- Select HySecurity Smart DC swing operator service repairs where MX002006 is specified
- Open and close limit switch replacement on compatible SwingSmart DC systems
- Applications confirmed by the SwingSmart DC parts diagram and original switch layout
Features & Specifications
| Manufacturer | HySecurity |
|---|
| Product Type | Limit switch kit |
|---|
| Part Number | MX002006 |
|---|
| Application | Open/close limit switch replacement |
|---|
| Compatible Operator Type | HySecurity SwingSmart DC |
|---|
| Included Components | Two limit switches and four mounting screws |
|---|
| Notes | Limit adjustment and full gate travel testing are required after installation |
|---|
Also Known As / Related Part Numbers
- MX002006
- HY-MX002006
- HySecurity limit switch kit
- SwingSmart DC limit switch
- SwingSmart DC limit kit
- 2 limit switches with screws
Technician Note
After replacing limit switches, do not assume the previous travel setup is still correct. Cycle the operator carefully and confirm open/close positions, entrapment protection, and accessory inputs.
Before Ordering
- Confirm the operator is SwingSmart DC.
- Inspect the switch harness and connector before ordering.
- Check for physical damage to brackets or actuator hardware.
- Plan for limit adjustment after installation.
- Verify monitored safety devices operate correctly after service.
Important Ordering Warnings
- This kit is not for every HySecurity swing operator.
- Limit faults can also be caused by wiring, controller, or mechanical adjustment issues.
- Do not bypass limit switches or safety devices to keep an operator running.
Professional Advisory
Gate travel and limit service can create unsafe movement if the operator is adjusted incorrectly. Use a qualified gate technician when diagnosis or setup is uncertain.
Product Questions & Answers
What is included with MX002006?
The MX002006 kit includes two limit switches and four mounting screws for compatible SwingSmart DC operators.
What symptoms can point to a bad limit switch?
Inconsistent stopping, limit faults, overtravel, stopping short, or failure to complete travel can be related to limit switch or limit wiring problems.
Does this kit fit all HySecurity swing gate operators?
No. It is intended for SwingSmart DC applications where MX002006 is specified.
Do the limits need adjustment after replacement?
Yes. The operator should be adjusted and tested after replacing the limit switches.
Can I bypass a bad limit switch temporarily?
No. Limit switches should not be bypassed. Replace or repair the failed parts and test the operator correctly.