Liftmaster 25-4001-8K Overload, 1.2-1.8A
The LiftMaster 25-4001-8K overload is a 1.2 to 1.8 amp motor overload device used in select commercial door operator electrical boxes. In a contactor or motor starter circuit, the overload helps protect the motor by responding to sustained overcurrent conditions instead of acting like a simple on/off switch. It is a small part, but it is tied directly to motor protection and should be matched by the exact amperage range shown on the parts diagram or operator wiring documentation.
This item is most commonly searched as a replacement overload for LiftMaster commercial door operators where the original part is marked K25-4001-8K, 25-4001-8K, or 2540018K. The confirmed application found during review is the LiftMaster SJ1053 commercial door operator. Similar overloads with different amp ranges are not automatic replacements, even if the case style or mounting arrangement looks close.
What This Part Does
- Protects the motor starter circuit by tripping on sustained overcurrent conditions within its designed range.
- Supports commercial operator service where the parts diagram calls for a 1.2 to 1.8 amp overload.
- Helps prevent incorrect substitution of larger or smaller overload ratings in LiftMaster control boxes.
Compatible With
Known compatibility and application references found during this review include:
- LiftMaster SJ1053 commercial door operator applications where the parts diagram calls for K25-4001-8K or 25-4001-8K.
- Select LiftMaster commercial/industrial operator electrical boxes that specifically list a 1.2 to 1.8 amp overload in the parts diagram.
- Motor starter or contactor style control circuits only when the motor full-load amperage and operator documentation match this overload range.
Also Known As / Related Part Numbers
Use these references to compare labels, invoices, and older listings:
- K25-4001-8K
- 25-4001-8K
- 2540018K
- 1.2-1.8A overload relay
- LiftMaster 1.2 to 1.8 amp overload
Features & Specifications
| Feature / Specification | Details |
|---|
| Manufacturer | LiftMaster |
| Product Type | Thermal overload / motor starter overload |
| Part Number | 25-4001-8K |
| Common Kit Number | K25-4001-8K |
| Current Range | 1.2 to 1.8 amps |
| Application | Select LiftMaster commercial door operator control boxes |
| Confirmed Operator Reference | SJ1053 commercial door operator |
| Compatible Operator Type | Commercial / industrial door operators with matching starter circuit |
| Voltage / Phase | Match to operator wiring diagram and motor data label |
| Notes | Do not substitute by appearance or by a nearby amperage range. |
Technician Note
Set and apply this overload only according to the operator wiring diagram and the motor full-load amperage. If the original overload tripped repeatedly, inspect the door balance, drive train, motor, contactor, and power supply before assuming the overload alone is the problem.
Before Ordering
- Confirm the old part number or diagram callout is K25-4001-8K, 25-4001-8K, or 2540018K.
- Confirm the required overload range is 1.2 to 1.8 amps.
- Check the motor data label and operator wiring diagram before ordering.
- Do not replace a failed overload with a higher amp rating to stop nuisance trips.
- Use a qualified commercial door technician for diagnosis inside a high-voltage control box.
Professional Advisory
This is an electrical protection component. High-voltage troubleshooting, overload adjustment, and motor starter diagnosis should be handled by a qualified commercial door technician with power locked out and the correct LiftMaster documentation on site.
Product Questions
Is 25-4001-8K the same as K25-4001-8K?
Yes. K25-4001-8K and 25-4001-8K are commonly used references for the same 1.2 to 1.8 amp LiftMaster overload. Some listings also show 2540018K.
Can I use a different amp overload if it looks the same?
No. The overload must match the amp range required by the motor and operator wiring diagram. A larger or smaller overload can create nuisance trips or reduce motor protection.
Which operator is this overload confirmed with?
The confirmed application found during review is the LiftMaster SJ1053 commercial door operator. Other applications should be matched by the parts diagram.
Why did my overload trip?
Common causes include a binding door, worn drive components, incorrect voltage, motor problems, repeated high-cycle use, or an incorrectly set overload. The cause should be diagnosed before replacing parts repeatedly.
Is this a DIY replacement part?
It is normally a technician-level electrical part because it is installed inside a commercial operator control box. Lockout/tagout and proper electrical testing are required.