The Linear 2500-1776 is a 115V primary to 24V secondary transformer rated at 250VA for select Linear / OSCO commercial gate operator applications. In the operator, the transformer supplies 24VAC power to control circuits and related low-voltage loads. The 250VA capacity is important because the transformer has to support the required control circuit load without overheating or causing low-voltage dropouts.
This part is commonly tied to MSG-D service references and appears in Linear / OSCO replacement-part listings as a transformer only. It may also be associated with SWD repair references where the transformer assembly or parts diagram calls for this specific transformer. Because transformer fitment depends on voltage, VA rating, mounting, and terminal layout, confirm the operator model and serial range before replacing it. A failed transformer can be caused by age, lightning or surge damage, moisture, shorted low-voltage wiring, or an overloaded accessory circuit.
Use this transformer only where the Linear / OSCO parts diagram calls for part number 2500-1776 or a 115/24V 250VA transformer of the same configuration.
| Manufacturer | Linear / OSCO |
|---|---|
| Product Type | Transformer |
| Part Number | 2500-1776 |
| Input Voltage | 115V / 120V AC class |
| Output Voltage | 24V AC |
| Power Rating | 250VA |
| Application | Gate operator control power |
| Compatible Operator Type | Select MSG-D and listed Linear / OSCO commercial operator applications |
| Notes | Match primary voltage, VA rating, terminal layout, and parts diagram |
If the transformer secondary voltage is low or the replacement transformer fails, disconnect and test low-voltage loads. Accessory shorts and wet wiring can damage a new transformer quickly.
Transformer replacement involves line voltage on the primary side. Use a qualified gate technician for diagnosis, wiring, and post-replacement voltage checks.
Do not replace this transformer with a smaller VA unit, a different primary-voltage transformer, or a DC power supply unless the operator documentation specifically approves it.
It is used as a 115V/120V AC primary to 24V AC secondary transformer rated at 250VA.
It is commonly associated with MSG-D replacement-part applications, and may appear in other Linear / OSCO diagrams. Verify by model and parts diagram.
No. The VA rating must match the operator load. A smaller transformer can overheat or cause control power problems.
Common causes include surge damage, moisture, shorted accessory wiring, overloaded low-voltage circuits, or age-related failure.
Yes. Check incoming voltage, secondary wiring, accessory loads, fuses, and control circuit condition before installing a new transformer.