The Reno A&E BX-4 is the low-voltage model in the BX Series single-channel loop detector family. It is used when a vehicle loop is connected to a gate operator, barrier arm, parking controller, or access-control panel and the detector socket is supplied with low-voltage power rather than 120 VAC or 240 VAC. The BX-4 is one of the most common Reno detector service options because it covers many 12 VDC, 24 VDC, and 24 VAC style control cabinet applications. It provides one loop input and dual relay outputs, making it useful for safety, exit, presence, hold-open, and pulse style loop functions when configured correctly. The BX-4 is also commonly tied to older BX-LP or Model B low-voltage replacements, but it should be ordered by actual site voltage and wiring, not just by cabinet brand or a similar-looking detector body.
| Manufacturer | Reno A&E |
|---|---|
| Product Type | BX Series single channel vehicle loop detector |
| Part Number | BX-4 / BX4 |
| Application | Low-voltage vehicle detection for gates, barriers, parking, and access control |
| Input Voltage | 12 VDC / 24 VDC / 24 VAC family, often described as 10 to 35 VAC or VDC |
| Output Type | Dual relay outputs |
| Connector Style | 11-pin Amphenol-style detector connection |
| Setup | Eight external DIP switches and eight-position rotary sensitivity switch |
| Related Models | BX-3 120 VAC and BX-8 240 VAC are related voltage models, not automatic substitutes |
| Notes | Frequently used as a current replacement direction for some older low-voltage Reno detectors |
A BX-4 is commonly used in low-voltage detector cabinets, but the voltage should still be measured at the socket. Some older cabinets mix low-voltage accessory circuits with line-voltage terminals in the same enclosure.
Vehicle loop detectors and related wiring parts should be installed with the operator power off and tested with the gate, barrier, or door system in a controlled position. Do not bypass required safety devices. If the installation involves high voltage, damaged conduit, wet junction boxes, or uncertain relay wiring, use a qualified gate or access-control technician.
BX-4 is the low-voltage BX Series detector and is commonly associated with 12 VDC, 24 VDC, and 24 VAC detector power applications.
BX-4 is commonly listed as a replacement direction for BX-LP, but the site voltage, pinout, and output configuration should be confirmed.
Yes, it may be used for either function when wired to the correct controller input and configured for the needed relay behavior.
No. BX-4 is low-voltage, while BX-3 is 120 VAC. They are related BX Series models but not voltage-interchangeable.
A Reno 802-4 style 11-pin harness or SKT-11 style socket base may be used when the control cabinet is wired for an 11-pin detector.