The Security Brands Ascent X1, model 16-X1, is a cellular telephone entry system with keypad, call button, video calling, and Summit Control cloud management. It is designed for gate and door access applications where the property needs remote access control without running a dedicated phone line or hardwired internet connection to the entry point.
The Ascent X1 is a step up from a basic cellular keypad because it combines telephone entry, keypad access, video visitor identification, Wiegand input support, QR-code guest access, and cloud-based management in one entry unit. It is commonly used at gated homes, estates, small commercial properties, business entrances, private roads, service yards, gated parking areas, and access points where more flexibility is needed than a stand-alone keypad can provide.
This unit can control up to 2 gates or doors when properly wired and configured. Visitors can press the call button to reach approved phone numbers, while authorized users can grant access through the Summit Control app, text command, voice command, keypad code, Wiegand device, or GuestPass QR code. This gives the installer and property manager several ways to handle residents, employees, vendors, deliveries, guests, and service access.
The Ascent X1 uses 4G LTE cellular connectivity with automatic network selection and includes a smart SIM card ready for activation. Because it is a cellular access-control system, it requires an active Summit Control service plan and reliable cellular signal at the installed location. Keypad code management is handled through Summit Control, so codes cannot be added or deleted without active service.
The built-in video calling feature includes infrared support for low-light visitor identification. This gives the user a visual check of the visitor during a call, which is a major advantage over older audio-only telephone entry systems. The stainless-steel faceplate, powder-coated steel enclosure, LED downlight, LED-backlit buttons, and pluggable terminal blocks make the X1 a professional-grade option for outdoor gate and door access.
The Ascent X1 should not be confused with the Ascent R1, Ascent X2, Ascent M-series, Ascent K-series, or Ascent Switch models. The R1 is the smaller residential one-gate/one-door model. The X2 and M-series units are better suited for larger multi-tenant directory applications. The K-series models are cellular keypad units. The X1 sits in the middle as a powerful two-gate/two-door cellular telephone entry system with keypad, video, and Wiegand support.
The Security Brands Ascent X1 is intended for gate and door access-control applications where the controlled device accepts a compatible dry contact relay command. Final compatibility must be verified with the gate operator, door controller, electric lock system, Wiegand reader, power supply, and site wiring plan.
Important: The Ascent X1 does not power or replace the gate operator. It sends access commands to a compatible gate operator, door controller, or lock controller. The operator, lock power supply, safety devices, emergency access equipment, and gate or door hardware must be selected and wired correctly for the site.
| Feature / Specification | Details |
|---|---|
| Manufacturer | Security Brands / American Access Systems |
| Product Family | Ascent cellular access control |
| Product Type | Cellular telephone entry system with keypad |
| Manufacturer Model | 16-X1 |
| Common Store SKU | SB-16-X1 |
| Common Name | Ascent X1 |
| Access Point Capacity | Controls up to 2 gates or doors |
| Network | 4G LTE cellular with automatic network selection |
| Management Platform | Summit Control cloud-based access control platform |
| Access Methods | App, text, voice, keypad, call button, Wiegand device, and GuestPass QR code |
| Video Feature | Video calling with IR for low-light visitor identification |
| Wiegand Inputs | 2 Wiegand inputs |
| User Capacity | Up to 10,000 app, text, and voice users depending on plan |
| Keypad Code Capacity | Up to 10,000 keypad codes stored locally on the unit depending on plan |
| Rollover Calling | Up to 3 phone numbers |
| Broadcast Calling | Up to 10 phone numbers upon call button press |
| Notifications | Push and/or email event and status notifications |
| Schedules and Reports | Weekly event schedule and audit trail reporting through Summit Control |
| SIM Card | Smart SIM card preinstalled and ready for activation |
| Faceplate | Stainless-steel faceplate |
| Enclosure | Powder-coated steel enclosure |
| Lighting | LED downlight and LED-backlit buttons |
| Terminal Blocks | Pluggable terminal blocks |
| Input Power | 12-24 VDC; actual voltage should not be more than 10 percent beyond specified range |
| Included Power Supply | 24-VDC power supply, PS-24DC2, based on current manufacturer specification sheet |
| Current Draw | Less than 330 mA at 12 VDC; less than 160 mA at 24 VDC with relays latched and LED components on |
| Relay Contact Rating | 10 A at 120 VAC / 24 VDC |
| Maximum Switching Voltage | 250 VAC / 30 VDC |
| Maximum Switching Current | 15 A |
| Maximum Switching Power | 240 W / 2,770 VA |
| Operating Temperature | -15 degrees F to 158 degrees F |
| Dimensions | 6.68 in H x 10.00 in W x 5.25 in D |
| Shipping Weight | 8 lb |
| Mounting Note | Rear hole pattern for pedestal mounting is spaced at 3.063 in, with pilot holes for alternate mounting at 2.5 in |
| Warranty Reference | Two-year limited warranty commonly listed by the manufacturer |
| Important Service Note | Requires Summit Control activation and cellular service plan. Cellular signal should be verified at the installed location before final installation. |
Related item note: Pedestal, antenna extension kit, Wiegand reader, secondary keypad, gate operator, door controller, electric lock power supply, conduit, access-control cable, safety devices, loop detectors, fire department access equipment, and installation labor are separate unless the product listing specifically states that they are included.
The first thing to check on any cellular telephone entry installation is cellular signal at the exact mounting location. Do not rely only on signal strength from the house, office, driveway, or installer phone. The unit should be checked where it will actually be mounted, especially near masonry columns, metal enclosures, dense landscaping, long driveways, or low-signal areas.
The Ascent X1 controls up to 2 gates or doors through relay outputs. It does not replace the gate operator, door controller, safety loop, photo eye, receiver, or gate control board. The gate operator still needs proper power, limits, safety devices, entrapment protection, emergency access, and manual release setup.
Summit Control activation and service are part of the system. Keypad codes are managed through Summit Control, so customers should understand that adding and deleting codes is not handled like an older stand-alone keypad. An active plan is needed for normal cloud management and cellular operation.
The 2 Wiegand inputs are useful when the site needs a card reader, long-range reader, or secondary keypad, but the reader wiring and credentials must be planned before installation. Confirm reader format, cable distance, power requirements, and where each reader will be mounted before the unit is installed.
When wiring the unit, follow the gate operator or door controller manual for the correct relay input. Do not wire the relay into high-voltage operator power or lock power beyond the relay rating. Low-voltage access-control wiring should be clean, protected, and labeled so future service is easier.
The Security Brands Ascent X1 should be installed by a qualified gate, access-control, or low-voltage technician when the relay wiring, power supply, pedestal mounting, Wiegand wiring, antenna placement, Summit Control setup, or gate operator input wiring is not clearly understood.
Do not use this telephone entry system to bypass gate safety devices, monitored photo eyes, safety edges, loop detectors, stop circuits, emergency access devices, or required entrapment protection. The Ascent X1 only provides access-control commands; the gate operator must still be installed and tested as a safe automatic gate system.
After installation, test every access method being used. Confirm call button operation, app access, text commands, voice access, keypad codes, QR-code access, Wiegand reader operation, relay output, gate or door response, event notifications, cellular signal, emergency access, and gate safety-device response before turning the system over to the customer.
The Ascent X1, model 16-X1, is a cellular telephone entry system with keypad, call button, video calling, Wiegand inputs, and Summit Control cloud management for up to 2 compatible gates or doors.
No. The Ascent X1 uses 4G LTE cellular connectivity, so it does not need a traditional landline or hardwired internet connection when cellular service and Summit Control activation are set up correctly.
The Ascent X1 can control up to 2 gates or doors when properly wired and configured. Sites needing more than 2 controlled openings should review a different access-control layout or multiple Ascent units.
The Ascent R1 is the smaller residential one-gate/one-door model. The Ascent X1 can control up to 2 gates or doors and adds 2 Wiegand inputs, larger user capacity, and broader access-control flexibility.
Yes. The Ascent X1 includes 2 Wiegand inputs for compatible Wiegand readers, proximity readers, long-range readers, or secondary keypads where the reader format, wiring, and power requirements are matched correctly.
Yes. The Ascent X1 uses Summit Control cloud management and cellular service. Keypad code management and cellular access features require proper activation and an active service plan.
Yes. Depending on setup and active service, authorized users can grant access by app, text, voice, call button response, Wiegand device, or GuestPass QR code in addition to keypad codes.
Check cellular signal, mounting height, power source, relay wiring, Wiegand reader wiring, Summit Control activation, antenna placement, emergency access, and the gate operator safety system before completing the installation.