The BEA 10LZRFLATSCAN-RB LZR-FLATSCAN SW sensor-only replacement is part of BEA's door-mounted laser safety sensor family for automatic pedestrian swing doors. This product is used where the door needs a compact sensor on the moving leaf to watch the door face and hinge area instead of relying on older multi-box swing-door safety layouts. The LZR-FLATSCAN SW platform uses laser Time-of-Flight presence detection and is commonly selected for low-energy pedestrian entrances, healthcare doors, education buildings, office entries, and other automatic swing-door openings where clean door-mounted protection is needed.
This specific part is a right black sensor-only replacement. It is normally used when the existing LZR-FLATSCAN SW installation already has the proper compatible harness, mounting base, spacer if required, power supply, and door controller interface. Because it is sensor-only, it should not be assumed to include every accessory found in a complete low-energy kit. Match the original sensor label, hand, finish, connector arrangement, and installation style before using it as a replacement.
Correct fitment matters on this product. LZR-FLATSCAN SW is for automatic pedestrian swing doors, not driveway gate photo eye service, vehicle loop detection, overhead door commercial motion sensing, or general access-control input use. Full-energy swing doors normally require sensors on both sides of the door, while certain low-energy applications may use a single sensor on the approach side. Any replacement should be tested after installation for detection field, teach-in, monitoring, relay behavior, inhibit/reactivation logic, and safe door operation.
BEA’s LZR®-FLATSCAN SW is a LASER-based Time-of-Flight presence sensor for use as a stand-alone safety sensor on automatic pedestrian swing doors. This solution can also be used as a reactivation sensor on the approach side of low energy doors.
This superior technology generates 170 detection points across a single curtain, which allows LZR®-FLATSCAN SW to cover the entire face of a single door leaf including the hinge area.
Finger Detection Technology™ utilizes 100 detection points within the hinge area of the door, protecting hands and fingers while the door is in motion.
The LZR®-FLATSCAN SW is capable of exceeding the 156.10 section 8.2.2.3 standard for detection area and meets section 8.1.4 for monitoring.
Leading Edge Safety
Leading edge safety extends the detection area beyond the leading edge of the door for enhanced safety
Hand Gesture Setup™
Easy door width programming using Hand Gesture Setup™ reduces configuration time
UL10B/C Listed
Fire rated for up to one hour
Reduced Components
Hub-less system offers fewer components for easier setup and installation
Reduced Uncovered Zone
LASER technology provides a reduced uncovered zone of down to 3/4 inch
Background Independence
LASER technology ensures independence of all types of flooring (pedi-mats, carpet, reflective flooring, wet surfaces, etc.) and the surrounding environment of the door (guiderails, walls, weather)
| Specification | Manufacturer Technical Data | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Technology | LASER scanner, Time-of-Flight measurement | ||||||||
| Detection Mode | Presence | ||||||||
| Max. Detection Range | 13’ (diagonal) with reflectivity of 2% (e.g. at (W) × 5’ > max. (H) × 12’), see Page 15 of Users Guide | ||||||||
| Detection Area |
| ||||||||
| Angular Resolution |
| ||||||||
| Typ. Min. Object Size |
| ||||||||
| Emission Characteristics | IR LASER Wavelength 905 nm; max. output pulse power 25 W; Class 1 | ||||||||
| Supply Voltage | 12 – 24 VDC ±15% * | ||||||||
| Power Consumption | = 2 W | ||||||||
| Response Time |
| ||||||||
| Test Input | 30 VDC (max. switching voltage) low < 1 V high > 10 V (voltage threshold) | ||||||||
| Output | 2 electronic relays (galvanic isolation - polarity free) | ||||||||
| Max. Switching Voltage | 42 VAC / VDC | ||||||||
| Max. Switching Current | 100 mA | ||||||||
| LED Signals |
| ||||||||
| Dimensions | 5 1/2” (W) × 3 1/3” (H) × 1” (D) (mounting bracket adds 1/4”) | ||||||||
| Material / Color | PC / ASA / black (white), or silver | ||||||||
| Tilt Angles | 2 – 10° (without mounting bracket) | ||||||||
| Degree of Protection | IP54 (EN 60529) | ||||||||
| Temperature Range | -22 – 140 °F (if powered) | ||||||||
| Humidity | 0 – 95% non-condensing | ||||||||
| Vibrations | < 2 G | ||||||||
| Min. Door Leaf Speed | 2° / s | ||||||||
| Compliance | ISO 13849-1 PL “d” / CAT2; IEC 60825-1; IEC 60950-1; IEC 61000-6-2; IEC 61000-6-3; IEC 62061 SIL 2; UL 10B/C Fire-Rated 1 hour (file #R39071) - black material only |
This product is compatible by BEA LZR-FLATSCAN SW system type, door hand, finish, wiring, and door controller requirements. It is not selected by brand name alone.
| Manufacturer | BEA Sensors |
|---|---|
| Product Type | Door-mounted laser swing door safety/presence sensor |
| Part Number | 10LZRFLATSCAN-RB |
| Sensor Family | LZR-FLATSCAN SW |
| Hand / Mount Side | Right |
| Color / Finish | Black |
| Technology | Laser Time-of-Flight presence detection |
| Detection Use | Door leaf safety and hinge/pinch-zone safety on compatible automatic pedestrian swing doors |
| Typical Detection Range | Up to 13 ft diagonal under specified conditions |
| Power Requirement | 12-24 VDC +/- 15%; DC power only |
| Power Consumption | 2 W or less |
| Output | 2 electronic relay outputs, installation dependent |
| Protection Rating | IP54 |
| Dimensions | Approx. 5-1/2 in W x 3-1/3 in H x 1 in D; mounting bracket adds approximately 1/4 in |
| Important Note | Match hand, color, kit contents, controller input, power supply, and door type before ordering |
Before replacing a LZR-FLATSCAN SW sensor, confirm whether the door is low-energy or full-energy, which side of the door the sensor mounts on, the color of the housing, and whether the existing installation uses a complete kit or a sensor-only service part. A left sensor, right sensor, low-energy kit, and sensor-only replacement can look similar in a product search but may not solve the same field problem.
Automatic pedestrian door safety sensors should be installed, configured, and tested by a qualified automatic door technician. Do not bypass monitored safety inputs, remove required sensors, or substitute an unapproved sensor to keep a door running. After service, the door must be tested for detection coverage, approach-side behavior, swing-side behavior, pinch-zone protection, relay output, monitoring, and safe operation.
10LZRFLATSCAN-RB is described as a sensor-only replacement. It may not include every harness, mounting, power, or accessory component used in a complete low-energy or full-energy kit.
The LZR-FLATSCAN SW sensor is handed. The replacement must match the original left or right sensor position so the detection field, teach-in, and wiring layout match the door installation.
It may be used only where the installed LZR-FLATSCAN SW system, door controller, and safety requirements call for that exact sensor. Full-energy installations typically require sensors on both sides of the door.
Check DC power, wiring, harness condition, DIP switch settings, teach-in procedure, controller monitoring input, relay configuration, door position signal, and obstruction field before assuming the new sensor is defective.
Do not assume interchangeability. LZR-FLATSCAN SW, 3D SW, S, and WIDESCAN products serve different door or industrial applications and must be matched by the exact sensor family and part number.