Part Number: Hy-MX3009

Description

HySecurity MX3009, LOCK ASSY, MAGNETIC, M30/M50

The HySecurity MX3009 is a magnetic lock assembly used on select HySecurity / Nice HySecurity StrongArm M30 and StrongArm M50 crash barrier applications. This assembly is designed to help secure the barrier arm at the catch post when the barrier is in the closed position.

Unlike a standard pedestrian door mag lock, the MX3009 is a HySecurity crash barrier accessory designed around the StrongArm M30/M50 barrier arm, upper catch pin, strike plate, catch post, and Smart Touch Controller wiring. It should be ordered only when the operator documentation or parts diagram confirms MX3009 for the specific installation.

What This Magnetic Lock Assembly Does

The magnetic lock assembly holds the StrongArm crash barrier arm in the closed position by pairing a magnet assembly at the catch post with a strike assembly attached near the upper catch pin area. When properly installed, the lock helps the barrier remain seated and secured while still allowing controlled release through the operator control system.

For correct operation, the magnet and strike must be aligned, the bumper compression must be set correctly, and the Smart Touch Controller relay logic must be configured for the gate lock output. Poor alignment, incorrect wiring, or an improperly configured relay can make the lock appear defective even when the lock hardware is still serviceable.

Compatible With

This part may be used with the following applications where the current HySecurity parts diagram and installation documentation confirm fitment:

  • Select HySecurity StrongArm M30 crash barrier systems requiring the MX3009 magnetic lock assembly
  • Select HySecurity StrongArm M50 crash barrier systems requiring the MX3009 magnetic lock assembly
  • StrongArm M30/M50 applications using the correct catch post, upper catch pin, and strike plate arrangement
  • Repairs where the original magnetic lock assembly is marked, listed, or cross-referenced as MX3009
  • Installations where the Smart Touch Controller and power supply wiring are set up for the HySecurity StrongArm M30/M50 mag lock

Important: Do not assume this part fits every HySecurity barrier arm, StrongArmPark, StrongArm DOT, or unrelated mag lock installation. MX3009 is tied to the StrongArm M30/M50 crash barrier configuration and should be verified by model, serial number, and parts diagram.

Similar Parts That Are Not Interchangeable

Magnetic locks and barrier lock kits can look similar, but the mounting hardware, strike plate, controller wiring, arm/catch post geometry, and intended operator family may be different. A standard access control mag lock is not a direct substitute for this StrongArm M30/M50 assembly.

Part / Assembly Common Use Interchangeability Note
MX3009 Magnetic lock assembly for StrongArm M30/M50 crash barrier applications Correct part where MX3009 is specified by HySecurity documentation
Standard access control magnetic lock Pedestrian doors, gates, or access control openings Not a direct substitute for the StrongArm M30/M50 catch post and upper arm hardware
Other HySecurity lock kits Different HySecurity operator families or lock configurations Not interchangeable unless the current parts diagram confirms the same part number

Not Intended For

  • StrongArmPark barrier gate operators unless a HySecurity parts diagram specifically lists MX3009
  • StrongArm DOT applications unless confirmed by HySecurity documentation
  • Slide gate, swing gate, bollard, wedge, or hydraulic operator applications outside the listed StrongArm M30/M50 configuration
  • Pedestrian door access control mag lock replacement
  • Generic 12V or 24V magnetic lock substitutions without the required HySecurity mounting and strike hardware
  • Bypassing controller relay logic, gate lock outputs, safety devices, or entrapment protection

Important Compatibility Warning

The MX3009 magnetic lock assembly is designed around the StrongArm M30/M50 crash barrier arm and catch post layout. The strike plate, upper catch pin clamp, magnet height, bumper compression, and wiring must all be correct for the lock to hold and release properly.

If the barrier has been modified, repaired after impact, or fitted with non-original catch post hardware, verify the complete lock mounting area before ordering. A bent catch post, worn bumper, damaged upper catch pin, loose strike plate, or incorrect relay setup can cause lock issues that may not be corrected by replacing the magnetic lock alone.

Features & Specifications

Feature / Specification Details
Manufacturer HySecurity / Nice HySecurity
Part Number MX3009
Product Type Magnetic lock assembly / mag lock kit
Common Operator Family Select HySecurity StrongArm M30 and StrongArm M50 crash barrier applications
Common Description Lock Assy, Magnetic, M30/M50
Primary Function Helps secure the StrongArm crash barrier arm in the closed position at the catch post
Typical Mounting Area Catch post magnet assembly with strike assembly at the upper arm/catch pin area
Control Integration Used with Smart Touch Controller gate lock output wiring where specified
Power / Wiring Note Associated with 24VDC mag lock wiring in HySecurity installation documentation; verify the current wiring diagram before service
Package Contents Mag lock assembly/kit; commonly described with magnet and strike hardware. Confirm current package contents before ordering.

Also Known As / Related Part Numbers

  • MX3009
  • MX-3009
  • HySecurity MX3009
  • Nice HySecurity MX3009
  • HYS-MX3009
  • HYS MX3009
  • HySecurity Lock Assy, Magnetic, M30/M50
  • HySecurity Magnetic Lock Assembly M30/M50
  • HySecurity StrongArm M30/M50 Mag Lock
  • StrongArm CRASH Mag Lock
  • StrongArm M30 Magnetic Lock Kit
  • StrongArm M50 Magnetic Lock Kit
  • Magnetic Lock Kit for StrongArm M30/M50
  • Magnet assembly and strike assembly for StrongArm M30/M50 - related description, verify package contents

Related Parts and Accessories

  • Upper catch pin hardware for StrongArm M30/M50 where listed in the parts diagram
  • Catch post hardware and mounting components used with the StrongArm M30/M50 barrier arm
  • Strike plate and clamp hardware associated with the mag lock assembly
  • Power supply board components if the mag lock is not receiving proper 24VDC power
  • Smart Touch Controller components if relay output or gate lock logic is not operating correctly
  • Bumper and arm seating components if the strike does not rest correctly on the magnet

Technician Note

Before replacing the MX3009, inspect the physical alignment first. The strike should sit squarely on the magnet after the bumper compresses. If the catch post is bent, the arm is not seating fully, the bumper is damaged, or the upper catch pin hardware is loose, the magnetic lock may not hold consistently.

Also check the electrical side. A failed power supply output, incorrect user relay setup, loose crimp connection, damaged wire through the pivot post, or incorrect Smart Touch Controller relay logic can make the mag lock act like it has failed. Do not bypass the lock output or force the barrier to operate against a misaligned lock.

Before Ordering, Confirm

  • The original part number is MX3009.
  • The operator is a HySecurity StrongArm M30 or StrongArm M50 crash barrier system.
  • The current parts diagram lists MX3009 for the specific model and serial number.
  • The catch post and upper catch pin arrangement match the HySecurity mag lock installation layout.
  • The strike plate, clamp, magnet, and mounting hardware needed for the repair are included or being ordered separately as required.
  • The barrier arm is not bent and the catch post has not shifted from impact damage.
  • The 24VDC power supply, wiring, crimp connections, and controller relay output have been checked.
  • The Smart Touch Controller relay logic is configured correctly for gate lock output.
  • The issue is not being caused by bumper wear, mechanical misalignment, damaged catch hardware, or prior field modifications.

Installation and Service Notes

  • Disconnect power and follow proper lockout procedures before servicing the barrier operator.
  • Do not modify or bypass the Smart Touch Controller lock output, safety devices, limit setup, or entrapment protection.
  • Confirm that the magnet and strike plate are aligned before final tightening.
  • Check that the strike rests properly on the magnet after the bumper is compressed.
  • Route and protect wiring so it does not rub, pinch, or pull during barrier movement.
  • After installation, test the barrier through full operation and confirm that the mag lock holds and releases at the correct time.
  • Recheck all safety devices and site access-control commands after the lock service is complete.

Professional Advisory

The MX3009 is used on crash-rated barrier equipment where safe movement, proper lock release, and correct controller operation are critical. Service should be performed by a qualified gate technician if the issue involves Smart Touch Controller wiring, 24VDC power supply diagnosis, relay configuration, catch post alignment, arm impact damage, or unknown prior modifications.

Do not bypass the magnetic lock, safety devices, entrapment protection, controller outputs, limit functions, or access-control interlocks to keep the barrier running. If the barrier arm is not seating correctly or the lock is not releasing properly, the system should be inspected before continued operation.

Product Questions & Answers

Is the HySecurity MX3009 made for StrongArm M30 and M50 barriers?

Yes. The HySecurity MX3009 is a magnetic lock assembly commonly used with select StrongArm M30 and StrongArm M50 crash barrier applications where the parts diagram confirms fitment.

Is MX3009 a standard door magnetic lock?

No. MX3009 is a HySecurity StrongArm M30/M50 barrier mag lock assembly. It is designed around the catch post, upper catch pin, strike hardware, and controller wiring used on those crash barrier systems.

What parts are commonly included with the MX3009 magnetic lock assembly?

The kit is commonly described as including the magnet assembly for the post and the strike assembly for the upper arm area. Package contents can change, so the required hardware should be confirmed before ordering.

What voltage does the StrongArm M30/M50 mag lock wiring use?

HySecurity installation documentation shows the mag lock connected to the Smart Touch Controller and 24VDC power supply. Always verify the current wiring diagram and operator configuration before servicing the lock.

Why would the MX3009 magnetic lock fail to hold?

A weak or inconsistent hold can be caused by poor magnet and strike alignment, a worn bumper, bent catch post, loose upper catch pin hardware, low power, wiring problems, or incorrect relay logic.

Can I use this lock on a StrongArmPark barrier gate?

Do not assume MX3009 fits a StrongArmPark operator. This part should only be used on StrongArm M30/M50 applications where the HySecurity parts diagram lists MX3009.

Should the magnetic lock be bypassed if the barrier will not open?

No. The magnetic lock, safety devices, controller outputs, limits, and access-control interlocks should not be bypassed. If the lock is not releasing or the barrier is unsafe, a qualified gate technician should inspect the system.