The MMTC HBF-CC is an interior, flush-mount open-close key switch used where a keyed command station is needed at a commercial door, gate, or controlled access point. It mounts in a single-gang back box and uses a stainless steel faceplate, making it a clean option for offices, equipment rooms, service doors, and interior wall stations where the switch is protected from weather.
This version is built for a changeable core cylinder, which is useful when the facility wants the keying to match an existing key-control program. The switch is center-return, so the key is used to send an open or close command and then returns to the neutral position. Correct wiring matters because this is not a full open-close-stop station and should not be selected when the operator requires a stop button at the same control point.
Use this item when replacing an existing HBF-CC, LiftMaster 02109U style station, or a similar interior open-close changeable-core key switch with the same mounting and wiring requirements.
| Manufacturer | MMTC |
| Product Type | Interior flush-mount key switch |
| Part Number | HBF-CC |
| Related LiftMaster Number | 02109U |
| Application | Keyed open-close command station |
| Mounting Style | Single-gang flush mount |
| Enclosure Rating | NEMA 1 interior |
| Cylinder Type | Changeable core cylinder |
| Faceplate | Stainless steel, 4-1/2 in H x 2-3/4 in W |
| Back Box | 4 in H x 2 in W x 2 in D |
| Function | Open-close, center return |
| Notes | Dry-contact command wiring; not a stop station |
Use the HBF-CC when the job specifically calls for a changeable core cylinder. It should not be swapped with HBF-BC, HBF, or SLF versions unless the cylinder system and keying plan are being changed on purpose.
Key switch wiring should follow the operator manufacturer wiring diagram. Do not use a two-position key switch as a substitute for required monitored safety devices, emergency stop controls, or required egress hardware.
HBF-CC is for a changeable core cylinder. HBF-BC is for a Best cylinder or equivalent. The faceplate and general HBF style are similar, but the cylinder requirement is different.
No. HBF-CC is an interior NEMA 1 flush-mount key switch. Use an exterior-rated key switch for exposed outdoor locations.
No. This is an open-close center-return key switch. If the operator or job requires a stop button, use a station designed with a stop button.
It may be used with select gate operators that accept dry-contact open-close key switch inputs. Always verify the operator terminals and wiring diagram.
The cylinder style determines what lock core and key system the station can use. Matching the existing keying system is important for facility access control.