The Miller Edge AW14K500-12-RF is a non-monitored wireless Air-Wave system for select motorized commercial door applications. It combines an AW14-RF pneumatic transmitter switch, an MRF-01 receiver, and a 12-foot length of RAH-500 gum rubber hose.
When the RAH-500 hose is compressed, an air-pressure wave travels through the connecting tube to the diaphragm inside the AW14-RF. The integrated transmitter sends a wireless signal to the MRF-01 receiver, which closes its normally open output so the connected operator can provide its programmed stop or reverse response.
The AW14K500-12-RF eliminates the moving coil cord or retracting reel normally used between a door-mounted pneumatic sensing edge and the operator. The AW14-RF mounts on the moving door near the Air-Wave hose, while the MRF-01 receiver remains wired to the operator control circuit.
The pneumatic switch has adjustable sensitivity to match the hose length and installation conditions. A pressure and temperature compensation valve helps reduce changes in operation caused by environmental conditions.
AW14K500-12-RF is a non-monitored wireless system. It does not provide 10K resistance, pulsed monitoring, diode-capacitor monitoring, or another supervised safety signal.
Miller Edge describes the AW14-RF-K10 system as ideal primarily for door operators manufactured before August 2010. It must not replace a required monitored sensing edge, monitored photo eye, or other approved entrapment-protection device on an operator that requires supervision.
Verify the operator manufacturer, complete model number, production date, control-board part number, edge-input function, receiver power, and current operator manual before ordering.
The MRF-01 provides a 2-wire normally open output for a compatible low-voltage edge, safety, or reversing input. When the receiver receives an activation signal from the AW14-RF transmitter, it closes the relay contact.
An operator terminal labeled EDGE, SAFETY, REVERSE, or N.O. does not automatically confirm compatibility. The operator must permit a non-monitored normally open device for the intended function.
Metal door sections, operator cabinets, structural steel, nearby radio equipment, antenna placement, and lack of clear line of sight can reduce actual wireless range.
The 12-foot designation refers to the supplied length of RAH-500 hose. It does not identify transmitter range, receiver wire length, or maximum separation between the transmitter and receiver.
Miller Edge instructions state that the AW14-RF system family may be installed on doors up to 18 feet wide. This does not mean that a 12-foot hose is correct for every door up to that width. Confirm the required finished sensing-edge length before ordering.
| Specification | Details |
|---|---|
| Brand | Miller Edge |
| System Part Number | AW14K500-12-RF |
| Product Type | Wireless Air-Wave sensing-edge component system |
| Monitoring Type | Non-monitored |
| Detection Technology | Pneumatic air pressure |
| Transmitter and Switch | AW14-RF |
| Receiver | MRF-01 single-channel receiver |
| Receiver Output | 2-wire normally open contact |
| Transmitters Per Receiver | Up to 8 compatible transmitters |
| Frequency | 915 MHz with FSK modulation |
| Nominal Wireless Range | 50 feet |
| Maximum Wireless Range | Up to 100 feet under optimal conditions |
| Nominal Response Time | Approximately 100 milliseconds |
| Transmitter Battery | One CR2032 3V lithium coin-cell battery |
| Transmitter Indicator | Red transmit LED |
| Transmitter Antenna | Integral PCB loop |
| Receiver Antenna | Attached wire antenna |
| Receiver Current Draw | 50 mA maximum according to the linked installation instructions |
| Receiver Power | Verify current MRF-01 label; official documents conflict on AC and DC ranges |
| Receiver Wiring | Integral 18-inch wiring |
| Adjustable Sensitivity | 0.078-19.70 inches water column |
| Maximum Pneumatic Load | 78.70 inches water column |
| Hose Model | RAH-500 gum rubber hose |
| Hose Length | 12 feet |
| Hose Size | 1/2-inch inside diameter with 1/8-inch wall |
| Transmitter Enclosure Material | ABS |
| Receiver Enclosure Material | Polycarbonate |
| Transmitter Dimensions | Approximately 1-15/16 inches wide x 3-3/8 inches high x 1-11/16 inches deep |
| Receiver Dimensions | Official sell sheet and installation instructions show different dimensions; verify current production unit |
| Agency Compliance | FCC Part 15 |
| Manufacturer Warranty | 2 years, subject to current Miller Edge warranty terms |
Mounting screws for the AW14-RF transmitter and MRF-01 receiver are not listed as supplied in the installation instructions. Sensing-edge extrusion, mounting channel, operator wiring accessories, tools, and additional safety devices are also not confirmed as included.
The green MRF-01 antenna wire must remain visible to the transmitter and should not be placed behind metal. The receiver should be mounted near the operator so its integral wiring can reach the control terminals without placing the antenna in a shielded location.
The RAH-500 hose, P-50 plug, P-50H plug, connecting tube, and barbed fitting must remain airtight. A split hose, leaking plug, loose fitting, blocked tube, or incorrect sensitivity adjustment can cause missed activations or nuisance reversals.
Longer pneumatic edges generally require more sensitivity. Excessive sensitivity can allow normal door vibration to activate the system.
Installation, receiver wiring, transmitter programming, sensitivity adjustment, pneumatic assembly, and final testing must follow current Miller Edge instructions, the operator manufacturer manual, applicable electrical codes, and current commercial door safety requirements.
Never use this non-monitored system to bypass a monitored safety input, jumper an entrapment-protection circuit, or conceal a sensing-edge fault. Do not connect the receiver output directly to a motor or an unsuitable line-voltage circuit.
A qualified commercial door, garage door, low-voltage, or industrial-controls technician should complete the work when the receiver voltage, operator input, RF placement, pneumatic assembly, or required safety response is unclear.
The kit includes an AW14-RF wireless Air-Wave transmitter/switch, MRF-01 receiver, CR2032 lithium battery, 12 feet of RAH-500 hose, P-50 closed plug, P-50H plug with hole, and 218-27-18 barbed connector.
No. It is a non-monitored wireless Air-Wave system and must not replace a monitored entrapment-protection device when the operator requires one.
The MRF-01 provides a 2-wire normally open contact for a compatible low-voltage edge, safety, or reversing input.
The system has a 50-foot nominal range and may operate up to 100 feet under optimal conditions. Metal obstructions, antenna placement, and radio interference can reduce actual range.
The transmitter uses one CR2032 3V lithium coin-cell battery. The documented AW14-RF package includes one battery.
Yes. Miller Edge instructions state that up to eight compatible transmitters can be programmed to one MRF-01 receiver.
No. It refers to the supplied RAH-500 gum rubber hose length. Wireless range is 50 feet nominal and up to 100 feet under optimal conditions.
No. The operator must permit a non-monitored normally open edge input and provide compatible receiver power. Verify the operator model, manufacture date, control board, and current manual before ordering.