PRICE
$309.94
Part Number: TS-PRSP-H

Description

Transmitter Solutions PRSP-H Multi-Technology Credential and Single Gang Reader Details

The Transmitter Solutions PRSP-H is a Pulse High Security single gang card reader for compatible access control systems. Current Transmitter Solutions documentation identifies MIFARE DESFire, HID and EM credential support and provides an option of 26-bit Wiegand or OSDP output.

The supplied catalog title identifies 13.56 MHz high-security and 125 kHz proximity technologies. Match the actual credential technology, card format, facility code and access controller before ordering. A reader may recognize a credential technology while the access controller still rejects the credential because the format or system programming does not match.

Multi-Technology Credential Support

Transmitter Solutions documents the PRSP-H with the following credential technology references:

  • MIFARE DESFire.
  • ISO14443A-DESFire reader application.
  • HID credential support.
  • EM credential support.

The PRSP-H is listed in the Transmitter Solutions Pulse High Security product family. The current manufacturer product page specifically lists MIFARE DESFire, HID and EM among the reader features.

Do not assume every HID, EM or DESFire credential will automatically work with every access control controller. Credential encoding, bit format, facility code and controller configuration must also be compatible.

26-Bit Wiegand or OSDP Controller Interface

The official PRSP-H documentation specifies an option of 26-bit Wiegand or OSDP output. The manufacturer wiring guide identifies Data0 and Data1 conductors for Wiegand and RS485A and RS485B conductors for the RS485 interface used with the documented OSDP application.

Wiegand and OSDP are different access control communication methods. The reader and access controller must be configured and wired for the same supported interface.

Do not connect RS485 conductors as Wiegand Data0 and Data1 or assume an existing Wiegand reader installation is automatically ready for OSDP. Verify the access controller interface and system configuration before installation.

Single Gang Card Reader Mounting

The PRSP-H is specifically identified in the manufacturer cut sheet and manual as a single gang card reader. Its documented dimensions are 4-1/2 inches long x 3-1/4 inches wide x 3/4 inch deep.

The manufacturer documents a metal back plate and non-drop bottom retaining screw. The mounting instructions direct the installer to secure the metal plate with two or four screws depending on the gang box, clip the reader onto the upper edge of the plate, and secure the reader at the bottom.

Verify the existing gang box, cable opening, mounting surface and back plate before replacing another reader. Similar single gang readers may use different mounting plates or cable clearances.

PRSP-H Versus PKSP-H

The PRSP-H and PKSP-H share several documented access control and credential features, but they should not be treated as the same product.

  • PRSP-H is identified by Transmitter Solutions as a single gang card reader.
  • PKSP-H is identified as a single gang keypad and multi-technology card reader.
  • PRSP-H is intended for card or credential presentation without the dedicated visible numeric keypad provided on PKSP-H.
  • Both model numbers should be matched carefully when replacing an existing Pulse High Security reader.

Do not order by outside dimensions alone. Check whether the existing installation requires credential-only reading or an integrated keypad.

Important Manufacturer Document Keypad Wording Conflict

The current PRSP-H product page and official PDF title identify PRSP-H as a single gang card reader. The product image also shows a card presentation reader without the numeric keypad used on the PKSP-H.

However, the current official PRSP-H PDF includes a "Touch Sensor Keypad" feature bullet and a "Keypad bit burst" specification. The same manual also contains generic troubleshooting text for a number pad reader.

This keypad wording conflicts with the PRSP-H product title, reader image and the separately listed PKSP-H keypad model in the Pulse High Security family. The PRSP-H should be treated as the card reader model, and keypad functions should not be promised for PRSP-H without additional manufacturer confirmation.

Indoor and Outdoor IP65 Application

Transmitter Solutions documents the PRSP-H for indoor and outdoor use and lists an IP65 certified rating.

The current manufacturer instructions include an outdoor installation caution stating that the protective film on the reader screen must be removed when installing the reader outdoors.

Proper reader mounting and cable routing are still required. An IP65 reader rating does not mean the gang box, cable penetration or wiring connections behind the reader are automatically protected from water intrusion.

Power and Wiring Requirements

Current Transmitter Solutions specifications list an operating voltage of 10V-15VDC and a maximum operating current of 160mA.

The manufacturer manual specifies a linear DC power supply and 22 AWG shielded cable. The documented maximum wiring distance is 492 feet using 22 AWG shielded cable, with single-point grounding of the cable shield.

The manufacturer wiring guide identifies the following conductors:

  • Red: +12VDC power to the reader.
  • Black: signal ground.
  • Green: Wiegand Data0.
  • White: Wiegand Data1.
  • Yellow: red LED control, active low.
  • Blue: green LED control, active low.
  • Brown: buzzer input, active low.
  • Orange: tamper output, open collector, active low, maximum 100mA.
  • Purple: doorbell output, open collector, +5VDC output at 5mA maximum.
  • Grey: RS485A.
  • Yellow and green: RS485B.

For damaged wiring, unidentified conductors, unclear controller inputs or RS485 communication faults, have a qualified access control or low-voltage technician verify the installation.

Credential Format and Controller Compatibility Warning

The manufacturer troubleshooting information specifically instructs the installer to verify that the access controller format setting matches the card format and recommends testing with an approved card of known format and facility code.

This is an important replacement check at HOAs, apartment buildings, commercial properties and other shared access systems. Do not replace multiple readers until an approved credential has been tested with the reader and controller configuration.

A credential labeled HID, EM or DESFire is not automatically compatible solely because PRSP-H supports that credential technology family.

Current Manufacturer Credential Documentation Difference

The current Transmitter Solutions product page lists MIFARE DESFire, HID and EM in the PRSP-H feature list and proximity card reader specification.

The current official PDF feature list also says DESFire, HID and EM, while the specification table narrows the proximity card reader line to ISO14443A-DESFire.

Because the feature list and specification table are not written identically, verify the exact current reader configuration and credential population when retaining existing HID or EM credentials is a required part of the project.

Mobile Credential Reference

The current Transmitter Solutions documentation states that mobile credentials are available using SynQ.

SynQ mobile credential operation should be verified against the current SynQ credential service, access controller and reader configuration before ordering equipment for a mobile access project.

Similar Readers Are Not Automatically Interchangeable

  • PRSP-H is the Pulse High Security single gang multi-technology card reader.
  • PKSP-H is the related single gang keypad and card reader model.
  • PRMP-H is the related mullion high-security card reader form factor.
  • A 125 kHz proximity-only reader is not automatically suitable for a DESFire high-security application.
  • A Wiegand-only reader is not automatically a replacement when the access controller requires OSDP.
  • A different DESFire reader may use another credential encoding or controller configuration.
  • A reader with similar physical dimensions can use a different back plate, voltage requirement or output protocol.
  • PRSP and PRSP-H part numbers should be matched carefully when high-security credential support is required.

Match the exact reader model, credential technology, controller format, Wiegand or OSDP interface and single gang mounting requirements before ordering.

Features and Specifications

Feature Specification
Brand Transmitter Solutions
Product Family Pulse High Security
Part Number PRSP-H
Product Type Single gang multi-technology card reader
Documented Credential Technologies MIFARE DESFire, HID and EM
Supplied Catalog Technology Reference 13.56 MHz high-security and 125 kHz proximity
Card Reader Standard Reference ISO14443A-DESFire
Output Option of 26-bit Wiegand or OSDP
IP Rating IP65 certified
Indoor or Outdoor Use Indoor and outdoor
Read Range 2-5 cm
Operating Voltage 10V-15VDC
Operating Current 160mA maximum
Documented Wiring Distance 492 feet with 22 AWG shielded cable
Temperature Rating -22 F to 158 F
Dimensions 4-1/2 x 3-1/4 x 3/4 inches
Weight 5-3/4 oz.
Mounting Style Single gang with metal back plate
Housing Features Non-scratch surface and non-drop bottom screw
Tamper Tamper protection with active-low open-collector output, 100mA maximum
Doorbell Output Open collector, +5VDC output at 5mA maximum
Keypad Function Not confirmed for PRSP-H; official PDF contains conflicting generic keypad wording

Also Known As and Related Product References

  • PRSP-H
  • Pulse High Security PRSP-H
  • Transmitter Solutions single gang multi-technology card reader
  • Wiegand and OSDP single gang reader
  • MIFARE DESFire, HID and EM card reader
  • 13.56 MHz and 125 kHz access control reader
  • Related keypad model: PKSP-H
  • Related mullion reader family: PRMP-H

Technician Note

The biggest ordering mistake with this reader is assuming the credentials will automatically carry over because the replacement is multi-technology. The access controller still has to accept the credential format and facility code. Also check the model number carefully: PRSP-H is the single gang card reader, while PKSP-H is the keypad reader version.

Before Ordering Checklist

  • Verify the required reader model is PRSP-H.
  • Confirm the installation requires a single gang card reader without a dedicated keypad.
  • Identify the existing credential technology: DESFire, HID, EM or another format.
  • Verify the credential bit format and facility code used by the access controller.
  • Confirm whether the controller requires Wiegand or OSDP.
  • Confirm the power source supplies 10V-15VDC and supports the 160mA maximum reader load.
  • Check the single gang mounting location, metal back plate and cable route.
  • Test an approved credential of known format before replacing multiple readers in a shared access system.

Installation and Service Notes

Use the manufacturer-documented linear DC power source and 22 AWG shielded cable. The Transmitter Solutions manual specifies single-point grounding of the cable shield.

Identify the controller communication interface before connecting Data0, Data1 or RS485 conductors. Do not mix Wiegand and RS485 connections based only on conductor color.

For outdoor installation, remove the protective film from the reader screen as specifically instructed by Transmitter Solutions.

If the reader beeps when a card is presented but the controller receives no card data, verify Data0 and Data1 wiring for a Wiegand installation, input voltage at the reader and the controller credential format. The manufacturer also recommends testing with an approved card of known format and facility code.

For OSDP communication faults, damaged wiring, unidentified access control conductors or unclear RS485 bus configuration, have a qualified access control or low-voltage technician inspect the system.

Product Questions and Answers

What credential technologies does the Transmitter Solutions PRSP-H support?

Transmitter Solutions documents MIFARE DESFire, HID and EM credential support for PRSP-H. Verify the exact credential format, facility code and access controller requirements before ordering.

Does the PRSP-H support both Wiegand and OSDP?

Yes. Current Transmitter Solutions specifications list an option of 26-bit Wiegand or OSDP. The reader and access controller must be configured and wired for the same supported communication method.

What is the difference between PRSP-H and PKSP-H?

PRSP-H is identified by Transmitter Solutions as the single gang card reader. PKSP-H is the related single gang keypad and multi-technology card reader. Verify whether the installation requires a dedicated numeric keypad before ordering.

Does the PRSP-H have a keypad?

The PRSP-H product page, PDF title and product image identify it as a single gang card reader without the dedicated numeric keypad shown on PKSP-H. The current PRSP-H PDF contains conflicting generic keypad wording, so keypad operation should not be promised for PRSP-H without additional manufacturer confirmation.

Can I reuse my existing HID, EM or DESFire credentials with PRSP-H?

Do not assume every credential will automatically carry over. PRSP-H is documented for MIFARE DESFire, HID and EM technologies, but credential encoding, card format, facility code and access controller configuration must also be compatible.

What voltage and current does the PRSP-H require?

Transmitter Solutions specifies 10V-15VDC operation with a maximum operating current of 160mA. The manufacturer manual calls for a linear DC power supply.

Is the PRSP-H rated for outdoor installation?

Yes. Transmitter Solutions documents indoor and outdoor use and an IP65 certified rating. The manufacturer also instructs installers to remove the protective film from the reader screen for outdoor installation.

Why does the PRSP-H beep when a card is presented but the controller receives no data?

For a Wiegand installation, verify Data0 and Data1 wiring, input voltage at the reader and the controller credential format. Transmitter Solutions also recommends checking the shield connection and testing with an approved card of known format and facility code.