The BEA 10SSTI48 is a SuperScan I primary active infrared presence sensor built for automatic pedestrian door safety and presence detection. This 48 inch version is ordered when the door width, sensor housing, and installed BEA SuperScan I system call for that exact length. Mounted on the door or header area depending on the application, the sensor uses distance-measuring active infrared detection to monitor the area around the moving door and help the operator react while a person or object is in the pattern. In service work, the most common ordering mistakes are choosing the wrong length, confusing primary and secondary units, or substituting a different BEA sensor family by appearance alone.
BEA’s SUPERSCAN-T INDUSTRIAL is an active infrared sensor designed for use in industrial environments that require presence and/or safety detection. This sensor can be used on automatic industrial doors, gates and industrial automation applications.
The SUPERSCAN-T INDUSTRIAL uses triangulation to detect the presence of an object, eliminating false detections caused by varying ground and environmental conditions.
In an industrial setting, this versatile sensor can be mounted stationary or on a moving object. Additionally, the SUPERSCAN-T INDUSTRIAL can be used as an individual module or daisy chained with up to 8 Secondary modules (9 total modules). This flexibility allows the SUPERSCAN-T INDUSTRIAL to be used on both narrow and wide doors and many other off door applications. Each module detection zone can be angled independently.
Fit To The application
Housing available up to 96 inches; can be field-cut to desired door width
User-Defined Detection Zones
Detection zone 24 to 96 inches
Adjustable Detection Zone
Can be set to background analysis mode to reduce the change of false detection from faulty environmental situations
Customizable Hold Time
Relay hold time can be adjusted from 0.1 to 4.5 seconds
Standards Compliant
Capable of external monitoring
| Specification | Manufacturer Technical Data |
|---|---|
| Technology | Active Infrared with background suppression |
| Detection Mode | Presence |
| Measurement of Distance | Triangulation |
| Power Supply | 12 – 24 VAC / VDC ±10% |
| Output Interface | Relay |
| Relay Maximum Contact Rating | 1A @ 30 V (resistive) |
| Detection Range | 0 – 8’ |
| Distance Adjustment | 2 – 8’ (rotating cam with linear adjustment) |
| Maximum Mounting Height | 8’ |
| Detection Signal Duration | Infinite Presence Detection |
| Detection Time | < 50 ms |
| Output Hold Time | Potentiometer range: 0.1 – 4.5 s |
| Operating Temperature Range | -30 – 140 °F |
| PCB Dimensions – Primary | 10.91" (W) × 1.5" (H) |
| PCB Dimensions – Secondary | 8.75" (W) × 1.5" (H) |
| Connector to Door Controller | 8-position screw terminal on Primary PCB |
| Primary-to-Secondary Connection | Flat-ribbon cable with connectors and key lock |
| Maximum Number of Secondarys | 8 |
| Function Selection | Detection mode: NO or NC Normal mode or Background Analysis mode |
| Manufacturer | BEA |
|---|---|
| Product Type | Door-mounted active infrared presence sensor |
| Part Number | 10SSTI48 |
| Sensor Family | SuperScan I / SuperScan-T |
| Application | Automatic pedestrian doors |
| Module Type | Primary only |
| Housing Length | 48 inch |
| Common Door Reference | 48 inch door reference |
| Detection Technology | Active infrared triangulation / distance measuring |
| Notes | Match length, primary/secondary configuration, and wiring |
Match the sensor length and primary/secondary configuration before ordering. A SuperScan I primary module should not be swapped with a secondary module or a different sensor family unless the door system is being redesigned and tested.
Automatic pedestrian door sensors and wireless controls should be installed, adjusted, and tested by a qualified automatic door technician. Do not use an activation sensor as a substitute for required presence, safety, or monitored protection devices.
The 10SSTI48 SuperScan I is a door-mounted active infrared presence sensor for compatible automatic swinging, revolving, folding, and low-energy door applications.
Yes. The uploaded item is identified as one primary SuperScan I module. Secondary modules or additional housings are separate unless the listing states otherwise.
SuperScan-T style sensors are commonly used individually or daisy chained with additional slave modules where the door width requires broader coverage.
No. SuperScan I and SuperScan II are related BEA sensor families but should not be treated as interchangeable without checking the installed system and wiring.
Match the original BEA part number, housing length, and door width reference. A different length can affect mounting, coverage, and appearance.