PRICE
$107.70
Brand: Genie
Part Number: GE-107311.0001.S

Description

GENIE 107311.0001.S, FLASHER, FS127

The Genie 107311.0001.S is a Flasher Module (FS127) designed for Genie commercial door operators. #8 screw mount - 18 AWG 6-inch leads for wiring connection. Solid-state flasher module that converts a steady warning lamp to a flashing signal for pre-close warning on commercial door operators.

Key Features

  • Converts steady warning lamp signal to flashing output for pre-close door warnings
  • Dual input voltage compatibility: 24VAC and 120VAC (+/- 15%), 50/60 Hz
  • Solid-state output rated 1A fullwave or 2A halfwave for reliable lamp switching
  • Default flash rate 75 FPM +/- 20%, field-adjustable 45-150 FPM at 50% duty cycle
  • Wide operating temperature range: -20 deg C to 60 deg C
  • Simple installation with #8 screw mount and 18 AWG 6-inch leads

Compatibility Guide

  • Genie Commercial Door Operators with timer-to-close expansion board
  • Genie Commercial Door Operators with auxiliary expansion module
  • Pre-close warning lamp circuits on compatible Genie commercial operators

Professional Specs

FeatureSpecification
ModelGenie 107311.0001.S
Item TypeFlasher Module (FS127)
Voltage24VAC, 120VAC
Contact ConfigurationSolid-state output: 1A fullwave or 2A halfwave
Mounting#8 screw mount - 18 AWG 6-inch leads for wiring connection
Alternate Part Numbers107311.0001.S

Frequently Asked Questions

Q: How does the FS127 flasher module function in a door operator system?

A: The FS127 flasher connects to the pre-close warning contacts on a timer-to-close expansion board or auxiliary expansion module and converts a steady lamp signal to a flashing output to warn personnel before the door closes.

Q: What input voltages does the FS127 flasher accept?

A: The FS127 accepts 24VAC or 120VAC input (+/- 15%) at 50 or 60 Hz. Ensure your warning circuit voltage matches one of these ratings before installation.

Q: What is the flash rate of the FS127 and can it be adjusted?

A: The default flash rate is 75 FPM +/- 20%. It can be field-adjusted within a range of 45 to 150 FPM to suit site-specific warning requirements.

Q: What is the operating temperature range of the FS127?

A: The FS127 is rated for operation from -20 deg C to 60 deg C (-4 deg F to 140 deg F), making it suitable for both indoor and typical outdoor commercial installations.

Q: How is the FS127 flasher module mounted and wired?

A: The FS127 mounts with a single #8 screw and connects via 18 AWG 6-inch leads. Secure the leads to the pre-close warning output contacts on the expansion board and fasten the module body to the operator chassis or enclosure.