PRICE
$42.80
Brand: Genie
Part Number: GE-112012.0001.S

Description

GENIE 112012.0001.S, ARMATURE ASSY,FS

The Genie Genie 112012.0001.S is a genuine OEM replacement armature assembly - fire safety (fs) designed for Genie commercial door operator systems. Electromagnetic armature assembly for Genie Fire Safety door operators; holds door in open position when energized; releases door for automatic fire closure when power is interrupted by fire alarm system. Constructed from Electromagnetic coil assembly with steel armature face plate and mounting hardware, this part meets Genie factory specifications for durability and performance. Dimensions: Per Genie FS operator specification; consult FS operator installation manual for mounting dimensions. Compatible with Genie Fire Safety (FS) series commercial door operators, Genie FS-rated MX operators, Genie FS-rated HX operators, Genie FS-rated CMH operators.

Key Features

  • Electromagnetic hold-open armature specifically designed for Genie Fire Safety (FS) door operator installations
  • Normally energized design - door is held open when power is applied; door releases and closes automatically on power interruption from fire alarm signal
  • Compatible with Genie FS fire safety circuit components: 112249 EOL resistor, 112325 EOLR relay, 112007 FS key switch
  • Enables automatic fire door closure to comply with NFPA 80 and local fire code requirements
  • Safety-critical component - test monthly or per AHJ requirements to confirm reliable release on fire alarm activation
  • Must be installed by qualified personnel and inspected by AHJ; do not substitute with non-FS components

Compatibility Guide

  • Genie Fire Safety (FS) series commercial door operators
  • Genie FS-rated MX operators
  • Genie FS-rated HX operators
  • Genie FS-rated CMH operators

Professional Specs

FeatureSpecification
ModelGenie 112012.0001.S
Item TypeArmature Assembly - Fire Safety (FS)
Voltage24 VDC (nominal, per Genie FS operator specification - verify with installation manual)
Contact ConfigurationElectromagnetic armature - normally energized (door held open), de-energizes on fire alarm signal to release door for closure
MaterialsElectromagnetic coil assembly with steel armature face plate and mounting hardware
DimensionsPer Genie FS operator specification; consult FS operator installation manual for mounting dimensions
MountingMounts to operator or door frame per Genie FS operator installation drawing; armature face mates with strike plate when door is in held-open position
Alternate Part Numbers112012.0001.S, GE112012-0001-S

Frequently Asked Questions

Q: How does the armature assembly function during a fire alarm event?

A: When the building fire alarm activates, it interrupts power to the FS operator circuit. The armature de-energizes, releasing the electromagnetic hold, and the door closes automatically under spring or gravity force to contain fire and smoke as required by fire code.

Q: What other Genie FS components work with the armature assembly?

A: Related FS system components include: 112249 end-of-line (EOL) resistor, 112325 EOLR relay, and 112007 FS key switch. These components work together to form a complete compliant fire safety door operator circuit.

Q: How frequently should the FS armature assembly be tested?

A: The armature assembly should be tested at intervals specified by NFPA 80 and local authority having jurisdiction (AHJ) requirements, typically monthly or annually. Test by activating the fire alarm circuit and confirming the door releases and closes fully and freely.

Q: Are there code compliance requirements for the fire safety armature installation?

A: Yes. Fire safety door operator installations are subject to NFPA 80 (Standard for Fire Doors and Other Opening Protectives) and must comply with local fire codes. The installation must be inspected and listed by the AHJ. Do not modify the FS circuit without consulting a qualified fire door technician.

Q: What are the signs of a failing FS armature assembly?

A: Failure symptoms include the door not holding in the open position when energized (indicating armature face contamination or coil failure), door not releasing on fire alarm activation (indicating wiring or relay fault), or the armature overheating. Contact Genie technical support and do not operate the door manually as a workaround - repair or replace promptly.