PRICE
$130.97
Brand: Genie
Part Number: GE-112518.0002.S

Description

GENIE 112518.0002.S, SWITCH ASSY,FUSE LINK,SX

The Genie 112518.0002.S is a fuse link switch assembly for use with Genie commercial door operators. Thermal fuse link switch assembly that breaks the control circuit on excessive heat for fire protection in Genie SX operators. Notable features include: thermal fuse link provides one-time-use fire protection by opening circuit on excess heat; designed specifically for genie sx series commercial operator; non-resettable - requires full assembly replacement after any heat event. Compatible with: Genie SX series commercial door operator, Fire-rated door operator installations requiring thermal fuse link protection, Commercial operators where SX enclosure fire protection is required. This is a genuine OEM replacement component for qualified service technicians.

Key Features

  • Thermal fuse link provides one-time-use fire protection by opening circuit on excess heat
  • Designed specifically for Genie SX series commercial operator
  • Non-resettable - requires full assembly replacement after any heat event
  • Critical fire safety component for fire-rated door operator installations
  • Ensures operator circuit integrity fails safe in fire conditions

Compatibility Guide

  • Genie SX series commercial door operator
  • Fire-rated door operator installations requiring thermal fuse link protection
  • Commercial operators where SX enclosure fire protection is required

Professional Specs

FeatureSpecification
ModelGenie 112518.0002.S
Item TypeFuse Link Switch Assembly
VoltageLow-voltage control circuit; per SX operator specification
Contact ConfigurationNormally closed thermal fuse link; opens circuit on excess heat event - non-resettable
MaterialsThermal fuse element with switch housing and wiring leads
MountingWired in-line within SX operator control circuit; mounted inside enclosure

Frequently Asked Questions

Q: What is a fuse link switch assembly and how does it protect against fire?

A: A thermal fuse link is a one-time-use safety device that permanently opens a circuit when exposed to heat above its rated temperature. It is used in fire-rated door operator installations to ensure the operator or door responds correctly to a fire event.

Q: Can the thermal fuse link be reset after it trips?

A: No. Thermal fuse links are non-resettable, one-time devices. Once triggered by a heat event, the entire assembly must be replaced before the operator can return to service. Never bypass or short a fuse link.

Q: When should I replace the fuse link switch assembly?

A: Replace the fuse link assembly any time the operator has been exposed to a fire event or high-heat condition, or if inspection reveals a blown fuse link. Annual inspection of fire safety components is recommended.

Q: How do I replace the fuse link switch assembly on the SX operator?

A: Disconnect power to the operator, remove the old fuse link assembly following the operator service manual, install the new assembly in the same orientation and wiring positions, restore power, and verify operator function.

Q: Are there any safety precautions I must follow when servicing this fuse link assembly?

A: Never bypass a thermal fuse link under any circumstances. Always use the OEM replacement part with the correct temperature rating. After any heat event, inspect all fire safety components before returning the operator to service.