PRICE
$630.66
Brand: Genie
Part Number: GE-113410.0001.S

Description

Genie GE-113410.0001.S Miller Edge MIM-62 Multi-Input Module

The Genie GE-113410.0001.S is the Genie-listed part number for the Miller Edge MIM-62 multi-input module. This module is used with select Genie gate operator installations where multiple monitored external entrapment devices need to be connected, assigned, and routed to compatible operator safety inputs.

The MIM-62 is an interface and expansion module, not a safety device by itself. It does not replace photo eyes, monitored sensing edges, gate operator safety inputs, or proper UL 325 entrapment-protection setup. It should be used only where the gate operator manual, safety-device documentation, and wiring layout confirm that the MIM-62 is the correct accessory.

Primary Use

  • Multi-input interface module for select monitored gate safety device installations
  • Used where Genie documentation lists Miller Edge MIM-62 with Genie part number 113410.0001.S
  • Helps expand a compatible gate operator safety setup to accept multiple monitored entrapment devices
  • Allows monitored photo eyes, monitored sensing edges, or approved monitored devices to be assigned through two outputs where supported
  • Used in installations with multiple open-direction and close-direction entrapment zones
  • Commonly used by professional installers when the gate layout requires more monitored safety devices than the operator board can directly accept

Compatible With

Use this module only where the installed gate operator documentation confirms the Miller Edge MIM-62 / 113410.0001.S as an approved accessory. Do not assume compatibility based only on the Genie brand name, the presence of safety terminals, or the number of safety devices on the gate.

  • Select Genie gate operators where the accessory table lists Multi Input Module, Miller Edge MIM-62, or 113410.0001.S
  • Select monitored entrapment-protection installations requiring up to 6 monitored device inputs and 2 outputs
  • Applications using compatible monitored photo eyes, monitored sensing edges, or wireless monitored edge systems where the device documentation supports the interface method
  • Installations requiring 2-wire pulsed, 4-wire pulsed, 10K, or normally closed monitored device interfaces where supported
  • Gate operator safety circuits where open-direction and close-direction monitored devices must be assigned correctly

Features and Specifications

Specification Details
Genie Part Number GE-113410.0001.S / 113410.0001.S
Manufacturer Model Miller Edge MIM-62
Product Type Multi-input module / monitored entrapment device interface module
Primary Function Expands compatible gate operator safety-device capacity for multiple monitored external entrapment devices
Inputs Up to 6 monitored device inputs where wired and configured according to the documentation
Outputs 2 outputs for routing monitored devices to compatible gate operator safety inputs
Supported Interface Types 2-wire pulsed, 4-wire pulsed, 10K, and normally closed monitored interfaces where supported by the connected devices and operator
Power Source Commonly listed as 10-24V AC/DC; verify the power source required by the installation manual before wiring
Current Consumption Up to 100 mA maximum, based on Miller Edge specification data
Relay Rating 1A at 24VDC where used according to the module documentation
Response Time 100 ms, based on Miller Edge specification data
Wake-Up Time Less than 500 ms, based on Miller Edge specification data
Operating Temperature -40 degrees C to +60 degrees C, where installed within specification
Housing Material Steel housing, based on Miller Edge specification data
Approximate Dimensions 4 in W x 4.75 in H x 1 in D, based on Miller Edge specification data
Approximate Weight 6.7 oz, based on Miller Edge specification data
Indicators Input status, power, and output active LED indicators where supported by the module version
Agency Status UL 325 Recognized Component, based on Miller Edge documentation

Important Comparison With Similar Safety Interface Parts

The MIM-62 is easy to confuse with the actual safety devices connected to it. Confirm whether you need the interface module, the monitored photo eye, the monitored sensing edge, or the operator control board before ordering.

  • GE-113410.0001.S / 113410.0001.S: Genie-listed part number for the Miller Edge MIM-62 multi-input module.
  • Miller Edge MIM-62: Multi-input module used to connect multiple monitored external entrapment devices and provide two outputs to a compatible gate operator.
  • Monitored photo eyes: Safety sensors that detect beam obstruction. They are connected to the MIM-62 where the system design supports it, but they are not included unless the package specifically says so.
  • Monitored sensing edges: Contact safety devices used on gate edges or entrapment zones. They are separate devices and must match the monitored input type being used.
  • Wireless monitored edge systems: Separate transmitter/receiver systems that may be connected through the MIM-62 where supported. They are not the same as the MIM-62 itself.
  • Gate operator control board: Not the same part. The MIM-62 is an accessory interface module, not the main operator controller.
  • Loop detectors and exit probes: Not the same function. Vehicle detection devices do not replace monitored entrapment-protection devices.

Also Known As / Related Part Numbers

  • GE-113410.0001.S
  • 113410.0001.S
  • GE1134100001S
  • 1134100001S
  • Genie GE-113410.0001.S
  • Genie 113410.0001.S
  • MIM-62
  • MIM62
  • Miller Edge MIM-62
  • MillerEdge MIM-62
  • Miller Edge multi-input module
  • MIM multi input module
  • Multi Input Module
  • Module, Multi-Input, MIM-62
  • 6 input to 2 output entrapment expansion module
  • Monitored safety device expansion module
  • Entrapment protection interface module

Technician Notes

  • Confirm the gate operator manual lists MIM-62 / 113410.0001.S before adding this module to the safety circuit.
  • The MIM-62 does not make an unmonitored device monitored. All connected devices must be compatible monitored entrapment-protection devices for the operator and safety input being used.
  • Confirm the input type for each connected safety device, such as 2-wire pulsed, 4-wire pulsed, 10K, or normally closed monitored wiring.
  • Assign each safety device to the correct output and gate direction. Open-direction and close-direction entrapment devices should not be mixed or guessed during setup.
  • Check power requirements before wiring. Some operator manuals may require an external listed power transformer or specific low-voltage power source for the module and connected devices.
  • If a gate will not close or shows a safety fault, inspect each connected device, wiring run, splice, input assignment, DIP switch, learned device status, and output connection before replacing the module.
  • Do not bypass monitored photo eyes, monitored safety edges, wireless monitored edge systems, inherent entrapment protection, or operator safety circuits to force the gate to move.

Before Ordering Checklist

  • Confirm the exact part number is GE-113410.0001.S or 113410.0001.S.
  • Confirm the manufacturer model needed is Miller Edge MIM-62.
  • Confirm the installed Genie gate operator manual lists MIM-62 as an approved multi-input module.
  • Confirm how many monitored entrapment devices need to be connected and which direction each device protects.
  • Confirm each connected safety device is compatible with the MIM-62 input type and the gate operator safety input.
  • Confirm the required output type and whether output A, output B, or both outputs are needed.
  • Confirm power source, voltage, current limits, and whether an external listed transformer is required.
  • Confirm the problem is not caused by a failed photo eye, bad edge sensor, damaged cable, water-filled conduit, incorrect DIP switch, unlearned device, or wrong safety input assignment.
  • Confirm package contents before assuming wires, connectors, transformer, enclosure, mounting screws, or safety devices are included.

Professional Advisory

The MIM-62 is used in monitored entrapment-protection circuits and should be installed only by a qualified gate technician familiar with UL 325 safety-device requirements. Incorrect wiring or assignment of safety devices can create unsafe gate movement, nuisance faults, or failure to protect the correct entrapment zone. Do not bypass monitored photo eyes, monitored sensing edges, wireless monitored edge systems, inherent entrapment protection, fire access equipment, fuses, grounding, or operator safety circuits. If the gate has multiple entrapment zones, dual-gate wiring, unknown prior modifications, or recurring safety faults, have the complete safety system inspected before returning the gate to service.

Product Q&A

What is Genie GE-113410.0001.S used for?

Genie GE-113410.0001.S is the Genie-listed part number for the Miller Edge MIM-62 multi-input module. It is used to connect multiple monitored external entrapment devices to select compatible Genie gate operator safety inputs.

Is GE-113410.0001.S the same as Miller Edge MIM-62?

Yes. GE-113410.0001.S is commonly used as the Genie part number for the Miller Edge MIM-62 multi-input module. Always confirm the installed operator manual and safety-device requirements before ordering.

Does the MIM-62 include photo eyes or safety edges?

Do not assume photo eyes, safety edges, wireless edge transmitters, wiring, or a transformer are included. The MIM-62 should be treated as the interface module unless the supplier package specifically lists additional components.

How many monitored devices can the MIM-62 accept?

The MIM-62 is commonly listed with up to 6 monitored device inputs and 2 outputs. The final setup depends on the gate operator manual, device type, input assignment, and the open or close direction being protected.

What monitored device types can be used with the MIM-62?

The MIM-62 supports monitored interfaces such as 2-wire pulsed, 4-wire pulsed, 10K, and normally closed monitored devices where the connected safety device and gate operator documentation confirm compatibility.

Can the MIM-62 be used to bypass a safety fault?

No. The MIM-62 should not be used to bypass, jump out, or ignore a safety fault. Safety faults should be diagnosed by checking each monitored device, wiring run, input assignment, output setting, power source, and operator safety status.

What should I check before replacing the MIM-62?

Check the part number, operator compatibility, connected safety devices, wiring, power source, DIP switches, learned device status, output assignment, water intrusion, damaged cables, and operator fault codes before replacing the module.