PRICE
$50.46
Brand: Genie
Part Number: GE-113436.0001.S

Description

Genie GE-113436.0001.S Linear Actuator Reset Button

The Genie GE-113436.0001.S is a linear actuator reset button service part for select Genie GLA24V gate operator repairs. Genie service documentation lists 113436.0001.S as Button, Reset, Linear Actuator, making this a replacement reset button component where the installed operator parts diagram confirms fitment.

This item should be treated as the reset button only unless the supplier package specifically states otherwise. It is not a control box enclosure, actuator arm, limit switch, disconnect switch, logic board, motor drive PCB, power supply, key set, buzzer, safety photo eye, or complete operator control assembly. Match this part by exact service number, operator model, reset button location, wiring layout, and package contents before ordering.

Primary Use

  • Replacement reset button for select Genie linear actuator gate operator service repairs
  • Used where the service parts diagram lists 113436.0001.S as the linear actuator reset button
  • Helps restore the proper reset-button function when the original button is damaged, stuck, broken, corroded, missing, or no longer operating correctly
  • Used in repairs where the original part is marked, ordered, or cross-referenced as GE-113436.0001.S or 113436.0001.S
  • Service component for the reset button circuit only, not a repair for every gate operator fault

Compatible With

Use this reset button only where the installed Genie operator documentation confirms 113436.0001.S as the correct service part. Do not assume it fits every Genie gate operator or every actuator system.

  • Select Genie GLA24V linear actuator swing gate operator service repairs where the parts diagram lists 113436.0001.S
  • Repairs where the original reset button is identified as Button, Reset, Linear Actuator
  • Applications where the reset button location, wiring, enclosure opening, and switch style match the installed Genie parts diagram
  • Service work where the reset button is damaged but the related control board, wiring, power system, and safety circuits have been checked separately

Features and Specifications

Specification Details
Brand Genie
Part Number GE-113436.0001.S / 113436.0001.S
Service Description Button, Reset, Linear Actuator
Product Type Reset button service component
Used With Select Genie GLA24V linear actuator gate operator repairs where 113436.0001.S is listed
Function Reset button input component for supported linear actuator gate operator service applications
Switch Type Verify switch type, connector, and wiring style against the installed unit before ordering
Electronic Board Included Do not assume included; logic board, motor drive board, and power supply are separate service parts unless specifically listed
Enclosure Included Do not assume included; the control box enclosure is a separate service part unless specifically listed
Programming Required No programming for the button itself; operator reset, travel, safety, or fault checks may be required after service
Package Contents Confirm before ordering; treat as the reset button only unless wiring, connector, nut, gasket, cap, hardware, or instructions are specifically listed

Important Comparison With Similar Genie Service Parts

Genie service parts with similar control-related names are not interchangeable. Confirm whether you need the reset button, an electronic board, the control enclosure, or another switch before ordering.

  • GE-113436.0001.S / 113436.0001.S: Linear actuator reset button service part for select Genie GLA24V repairs.
  • 113431.0001.S: Control box enclosure. This is the enclosure/housing and is not the reset button.
  • 113429.0001.S: 24V motor drive PCB assembly. This is an electronic board and not the reset button.
  • 113440.0001.S: Logic board assembly. This is the operator logic board and should not be confused with the reset button.
  • 113443.0001.S: 24V 350W power supply. This is a power component and not the reset button.
  • 113442.0001.S: UL325 gate operator buzzer. This is an audible warning component and is not the reset button.
  • Limit switches or travel sensors: Not the same part. A reset button should not be substituted for limit, travel, or position components.
  • Disconnect or manual release parts: Not the same function. The reset button does not replace mechanical release hardware or disconnect hardware.

Also Known As / Related Part Numbers

  • GE-113436.0001.S
  • 113436.0001.S
  • GE1134360001S
  • 1134360001S
  • Genie GE-113436.0001.S
  • Genie 113436.0001.S
  • Genie linear actuator reset button
  • Genie GLA24V reset button
  • Button, Reset, Linear Actuator
  • Reset button for Genie linear actuator gate operator
  • Gate operator reset button service part
  • 113431.0001.S - related control box enclosure, not the same part
  • 113429.0001.S - related 24V motor drive PCB assembly, not the same part
  • 113440.0001.S - related logic board assembly, not the same part
  • 113443.0001.S - related 24V power supply, not the same part
  • 113442.0001.S - related UL325 buzzer, not the same part

Technician Notes

  • Confirm the reset button is actually faulty before ordering. A gate that will not reset or will not run may have a power, battery, safety, motor, board, or wiring issue instead.
  • Inspect the button for sticking, broken cap, corrosion, water intrusion, damaged terminals, loose connector, cracked mounting area, or damaged wiring.
  • Check the control enclosure around the button. A cracked box, missing gasket, loose fitting, or bad wire entry can let water reach the reset button and internal electronics.
  • Do not confuse the reset button with a limit switch, disconnect switch, manual release, safety input, or stop input. These parts perform different functions.
  • If the reset button has been damaged by impact or water, inspect the logic board, motor drive board, power supply, fuses, batteries, and wiring before returning the system to service.
  • Label wiring before removing the old button. Do not guess on switch terminals, polarity-sensitive wiring, or board connections.
  • After replacement, verify reset operation, gate travel, safety devices, warning devices, battery backup, fault status, and full open/close operation.

Before Ordering Checklist

  • Confirm the exact part number is GE-113436.0001.S or 113436.0001.S.
  • Confirm the installed Genie operator is a compatible linear actuator model where the parts diagram lists 113436.0001.S.
  • Confirm you need the reset button, not the control enclosure, logic board, motor drive board, power supply, limit switch, disconnect switch, or buzzer.
  • Inspect the existing reset button, connector, wiring, gasket, mounting hole, and enclosure condition.
  • Confirm the gate problem is not caused by weak batteries, blown fuses, bad power supply, safety input fault, damaged actuator wiring, limit/travel issue, or control board failure.
  • Confirm whether wiring, connector, nut, gasket, cap, mounting hardware, or instructions are included.
  • Confirm the original button failure was not caused by water intrusion, impact, insects, corrosion, loose enclosure hardware, or previous incorrect service work.

Professional Advisory

Reset button replacement may involve control wiring, battery power, operator electronics, safety inputs, and moving-gate operation. If the gate has electrical damage, water intrusion, burned wiring, repeated faults, unknown prior modifications, or monitored safety-device issues, have the system checked by a qualified gate operator technician. Do not bypass monitored photo eyes, safety edges, reset circuits, fuses, grounding, warning devices, or operator control protections during diagnosis or repair.

Product Q&A

What is Genie GE-113436.0001.S used for?

Genie GE-113436.0001.S is a linear actuator reset button service part for select Genie gate operator repairs where the parts diagram lists 113436.0001.S.

Is GE-113436.0001.S the same as a limit switch?

No. GE-113436.0001.S is a reset button. Limit switches, travel sensors, disconnect switches, and safety inputs are different parts and should not be substituted for this reset button.

Does this reset button include the control box enclosure?

Do not assume the control box enclosure is included. The enclosure is a separate service part unless the supplier package specifically lists it with the reset button.

Can a bad reset button stop the gate from running?

It can, but a no-run condition can also be caused by weak batteries, blown fuses, a failed power supply, bad logic board, damaged motor drive board, safety faults, wiring problems, or actuator issues.

Which Genie operator uses this reset button?

This reset button is listed in Genie GLA24V linear actuator service documentation. Always confirm the installed operator model and parts diagram before ordering.

Does this part include wiring or a connector?

Package contents must be confirmed before ordering. Treat this item as the reset button only unless wiring, connector, nut, gasket, cap, or hardware is specifically listed.

What should I check before replacing the reset button?

Check the part number, button condition, wiring, connector, mounting hole, enclosure seal, water intrusion, fuses, batteries, power supply, control board status, safety inputs, and operator fault codes before replacing only the button.