The HySecurity MX001106 is a hydraulic pressure gauge kit for select HySecurity and Nice HySecurity gate operator systems. It is commonly listed as GAUGE & FITTINGS, 2000 PSI, 2 inch and as a Gauge, Pressure, 2000 PSI, Kit.
This kit is used to read hydraulic pressure on compatible HySecurity hydraulic operators. A pressure gauge is an important diagnostic tool when checking pump pack performance, relief pressure, braking behavior, hydraulic drive strength, and other pressure-related service conditions. It helps a trained technician determine whether the hydraulic system is operating within the expected pressure range for the specific operator.
Current listings commonly describe MX001106 as a 2000 PSI pressure gauge with a 2-inch dial, 1/4-inch NPT connection, and included fittings. HySecurity parts documentation lists MX001106 as a 2000 PSI pressure gauge kit in StrongArm M30/M50 hydraulic panel parts references, and distributor listings also associate the kit with select StrongArm M30/M50 and SlideDriver hydraulic operator applications.
The MX001106 gauge kit allows a technician to connect a pressure gauge to the appropriate hydraulic test point or service location on a compatible HySecurity hydraulic operator. Once installed correctly, the gauge can display system pressure so the technician can diagnose whether the pump pack, relief valve, braking manifold, hydraulic motor, hoses, or related components are performing correctly.
This kit is a diagnostic and service tool. It is not a repair by itself. If the gauge shows low, high, unstable, or no hydraulic pressure, the cause may be a pump pack issue, low fluid, contaminated fluid, leaking hose, faulty relief valve, brake valve problem, worn hydraulic motor, bad quick disconnect, or a gate that is dragging or binding.
The HySecurity MX001106 is intended for select HySecurity / Nice HySecurity hydraulic operator applications where a 2000 PSI pressure gauge kit is specified or where the compatible service port and fittings match the gauge kit. Compatibility depends on the operator model, pump pack configuration, gauge port, fitting type, pressure range, and current HySecurity service documentation.
Do not assume MX001106 fits every HySecurity hydraulic operator or every hydraulic test port. Similar pressure gauges may have different pressure ranges, port sizes, fitting styles, thread types, and service ratings. Always verify the operator service documentation before connecting a gauge.
MX001106 should be matched by gauge pressure range, connection size, fittings, operator service port, and HySecurity service guidance. A 2000 PSI gauge should only be used where that range is appropriate for the hydraulic system being tested.
Hydraulic pressure testing can be dangerous if fittings are loose, the wrong gauge is used, the pressure rating is exceeded, or the system is opened under pressure. Do not connect or remove gauge fittings from a pressurized hydraulic circuit. Service should be performed by a qualified gate technician familiar with HySecurity hydraulic operators.
| Feature / Specification | Details |
|---|---|
| Manufacturer | HySecurity / Nice HySecurity |
| Part Number | MX001106 |
| Product Type | Hydraulic pressure gauge kit |
| Common Description | GAUGE & FITTINGS, 2000 PSI, 2 inch |
| Alternate Description | Gauge, Pressure, 2000 PSI, Kit |
| Pressure Rating | 2000 PSI commonly listed |
| Gauge Size | 2-inch dial commonly listed |
| Connection Reference | 1/4-inch NPT connection commonly listed |
| Fittings | Fittings commonly listed as included; verify current package contents before publishing as guaranteed |
| System Area | Hydraulic pump pack / pressure diagnostic area |
| Common Operator References | StrongArm M30, StrongArm M50, and select SlideDriver hydraulic applications where service documentation confirms the gauge kit |
| Function | Allows hydraulic pressure readings during compatible HySecurity operator diagnostics and service |
| Included Items | Pressure gauge and fittings; verify adapters, fittings, sealant, instructions, and any service hardware against the current supplier package |
| Not Included Unless Listed | Hydraulic pump pack, valves, hoses, quick disconnects outside the kit, hydraulic fluid, manifolds, motors, controller board, and operator hardware unless separately listed |
The MX001106 gauge kit helps diagnose hydraulic pressure, but it does not correct the problem by itself. If the pressure reading is not within the expected range for the operator and test procedure, continue checking the pump pack, fluid level, fluid condition, relief valve, brake valves, hoses, quick disconnects, hydraulic motor, and gate movement.
Use the gauge only at the correct service point and only with compatible fittings. A wrong fitting, loose connection, or gauge used beyond its pressure rating can create a hydraulic fluid leak or unsafe condition. Do not open a pressurized hydraulic system to install or remove the gauge.
Hydraulic pressure testing should be done with the operator secured and the system serviced according to the current HySecurity procedure. Keep the gauge, fittings, and hydraulic service area clean so dirt or debris does not enter the hydraulic circuit.
After connecting the gauge at the correct service point, check the pressure only as directed by the operator service documentation. Do not guess pressure settings. If the gauge shows abnormal pressure, diagnose the hydraulic circuit before adjusting valves or replacing components. After testing, remove the gauge only when the system is safe and pressure has been relieved according to the service procedure.
Hydraulic pressure testing can involve high-pressure fluid, moving gate parts, pinch points, and pressure-rated fittings. A qualified HySecurity gate technician should use this kit when diagnosing hydraulic drive, braking, soft-start, or pump pack problems.
Do not bypass covers, guards, limits, monitored entrapment protection, photo eyes, safety edges, pressure controls, or other safety devices during hydraulic service. The operator should be fully tested after any hydraulic adjustment or repair to confirm proper movement, stopping, pressure response, and safety-device function.
The HySecurity MX001106 is a 2000 PSI hydraulic pressure gauge kit used for checking pressure on select HySecurity hydraulic gate operator systems.
Current listings commonly describe MX001106 as a 2-inch pressure gauge rated for 2000 PSI.
Current listings commonly describe the gauge as having a 1/4-inch NPT connection with fittings. Verify the service port and fitting requirements before ordering.
MX001106 is listed in HySecurity parts documentation for StrongArm M30/M50 hydraulic panel applications and is also commonly associated with select SlideDriver hydraulic service applications where compatible.
No. MX001106 is a diagnostic gauge kit. It helps read hydraulic pressure, but low pressure may be caused by pump pack issues, low fluid, contaminated fluid, leaking hoses, relief valve problems, brake valve problems, hydraulic motor wear, or gate drag.
Hydraulic pressure testing and adjustment should be performed by a qualified HySecurity gate technician using the current operator service procedure. Incorrect pressure adjustment can damage equipment or create unsafe gate operation.