PRICE
$963.24
Part Number: Hy-MX001644

Description

HySecurity MX001644, MOTOR ASSY,2 HP,1PH,50 HZ,2850

The HySecurity MX001644 motor assembly is a 2 HP, single-phase 50Hz service motor rated at 2850 RPM. It is used where a compatible HySecurity gate operator was built for a 50Hz electrical supply. This distinction matters because 50Hz and 60Hz motors do not always interchange safely or perform the same way under hydraulic load. A motor with the correct horsepower but the wrong phase, voltage, frequency, or RPM can create starting problems, heat, nuisance trips, and poor gate operation. Public data supports the core motor specification, but broad model-by-model compatibility is limited, so this product should be treated as an exact-part replacement. Confirm the original motor tag, operator serial number, and HySecurity parts diagram before ordering.

Common service reasons may include motor failure, heat, noise, damaged leads, worn hydraulic seals, missing hardware, limit-reference errors, or other symptoms tied to the specific part type. Always diagnose the operator first so the replacement part corrects the actual problem.

Compatible With

This part may be used with the following HySecurity applications when confirmed by part number, operator model, serial number, voltage package, and parts diagram:

  • Compatible HySecurity 50Hz operator configurations that specifically call for MX001644
  • May be used in select heavier 50Hz hydraulic gate operator builds requiring a 2 HP single-phase motor assembly
  • Use only when voltage, phase, frequency, HP, RPM, and pump coupling match the original motor
  • Not interchangeable with MX001642, MX001643, MX001637R, MX001647R, or MX001648R unless documentation supports it

Features & Specifications

FeatureSpecification
ManufacturerHySecurity / Nice HySecurity
Product TypeElectric motor assembly
Part NumberMX001644
Horsepower2 HP
Phase1-phase
Frequency50Hz
Speed2850 RPM
ApplicationCompatible HySecurity 50Hz operator configurations
Compatible Operator TypeExact-part replacement where MX001644 is shown in the parts diagram
NotesDo not substitute for 60Hz, 3-phase, or 24VDC motors without HySecurity documentation

Also Known As / Related Part Numbers

The following numbers and phrases are related search references, catalog aliases, or commonly associated part-number formats. Confirm whether a related number is an exact replacement before ordering.

  • MX001644
  • HYS-MX001644
  • HY-MX001644
  • HySecurity MX001644 motor assembly
  • HySecurity 2 HP 1PH 50Hz motor
  • HySecurity 2850 RPM single-phase motor
  • MX001644 50Hz motor

Technician Note

Do not select HySecurity service parts by appearance alone. Similar operators can use different motors, switches, manifolds, seals, voltages, phases, frequencies, horsepower ratings, or hardware revisions. Match the original part number and the operator parts diagram before replacing components.

Before Ordering

  • Verify the HySecurity part number printed on the old part or shown in the operator parts diagram.
  • Confirm the operator model, serial number, and production generation.
  • For motors, match horsepower, voltage, phase, frequency, RPM, motor type, and pump coupling arrangement.
  • For hydraulic parts, confirm the exact manifold, seal location, and whether the system must be depressurized before service.
  • For limit switch parts, confirm switch style, mounting hardware, harness condition, and limit adjustment procedure.
  • Inspect related components so a failed motor, leaking seal, or limit issue is not caused by another damaged part.

Professional Advisory

Gate operators can move heavy gates and may contain high-voltage wiring, stored hydraulic pressure, and monitored safety circuits. Do not bypass safety devices, limit switches, entrapment protection, or factory wiring. If the operator moves unpredictably, has missing safety devices, leaks hydraulic fluid, or requires electrical diagnosis, have the system inspected by a qualified gate technician.

Questions & Answers

What should I match before ordering the MX001644 motor?

Match the original HySecurity part number, horsepower, voltage, phase, frequency, RPM, shaft/coupler setup, and operator parts diagram. Do not substitute a similar motor only by physical size.

Is MX001644 a 50Hz motor?

Yes. This listing is written around the 50Hz, 2 HP, 1-phase, 2850 RPM specification shown for MX001644. Frequency matters because motor speed, current draw, and heat can change if the wrong motor is used.

Can MX001644 replace another HySecurity motor number?

It may be used in place of MX001644 only when the operator configuration and parts diagram support that substitution. Check the existing nameplate and HySecurity part reference before ordering.

Where is this HySecurity motor commonly used?

This motor is commonly associated with HySecurity 50Hz operator configurations that call for this exact 2 HP motor. Exact use depends on the operator model, voltage package, phase, and production generation.

Should a technician install this motor?

Yes for most commercial hydraulic gate operators. Motor replacement can involve high voltage, hydraulic pump coupling alignment, and safety-device checks, so a qualified gate technician should handle unsafe or unfamiliar work.