Linear 2500-174 125W 120V Heater Strip for Gate Operator Enclosures
The Linear 2500-174 is a 125W, 120V heater strip for select Linear / OSCO gate operator enclosures. Heater strips are used to help maintain a more stable internal cabinet environment in cold or damp conditions. They can help reduce condensation and temperature-related service issues around controls, limit components, and mechanical areas when installed in an operator designed to accept that heater.
This part is voltage-specific. The 2500-174 is the 120V heater strip, while similar listings may reference 230V heater strips under different part numbers. The replacement should match the original heater label and operator wiring diagram, not just the wattage.
Compatible With
May be used with select Linear / OSCO gate operator enclosures where the parts diagram specifies the 2500-174 125W 120V heater strip:
- Select Linear / OSCO commercial gate operator cabinets with factory heater strip provision
- Linear / OSCO slide, swing, or barrier operator applications only where 2500-174 is listed
- Operator enclosures requiring a 125W 120V heater strip
- Not a substitute for 230V heater strip applications such as part 2500-175 unless documentation confirms otherwise
Features and Specifications
| Manufacturer | Linear / OSCO |
|---|
| Product Type | Heater strip |
|---|
| Part Number | 2500-174 |
|---|
| Application | Gate operator enclosure heating and condensation control |
|---|
| Voltage | 120V |
|---|
| Wattage | 125W |
|---|
| Compatible Operator Type | Select Linear / OSCO operators with compatible heater provision |
|---|
| Notes | Match voltage, mounting, and wiring diagram before installation |
|---|
Also Known As / Related Part Numbers
- 2500-174
- 2500174
- LIN-2500-174
- LN-2500174
- Heater strip 125W 120V
- 125 watt 120 volt heater strip
- Related 230V heater strip 2500-175
- 2500-175 is related but not interchangeable without voltage confirmation
Technician Note
A heater strip should not be used to mask water intrusion. If the enclosure has standing water, failed seals, blocked drains, or damaged conduit entries, correct those issues before relying on the heater.
Before Ordering Checklist
- Verify the existing heater part number is 2500-174
- Confirm the operator heater circuit is 120V
- Check wattage and mounting style
- Inspect wiring, terminals, enclosure seals, and drain paths
- Use a qualified technician for high-voltage wiring or damaged electrical components
Professional Advisory
Commercial gate operator service parts should be installed with power safely disconnected and the operator secured against movement. For high-voltage wiring, moving gate hazards, or uncertain field conditions, use a qualified gate technician.
Important Ordering Warnings
Do not install a 120V heater strip on a 230V circuit or substitute a different heater without checking the wiring diagram. Incorrect voltage can create equipment damage or a safety hazard.
Product Questions and Answers
What is the 2500-174 heater strip used for?
It is used in select Linear / OSCO gate operator enclosures to help control cold-weather and condensation-related cabinet conditions.
What voltage is this heater strip?
The 2500-174 is listed as a 125W, 120V heater strip.
Is the 2500-174 the same as 2500-175?
No. 2500-175 is commonly associated with a 230V heater strip. Do not interchange them without confirming the operator wiring.
Can a heater strip fix water inside the operator cabinet?
No. It may help with condensation, but water intrusion, failed seals, or drainage issues must be corrected separately.
Who should install this part?
Because this is an electrical heating component, installation should be handled by a qualified gate technician or electrician when high-voltage work is involved.