Linear 2500-1742 6 Amp Slow-Blow Fuse for OSCO Gate Operators
The Linear 2500-1742 is a 6 amp slow-blow fuse for select Linear / OSCO gate operator circuits. A slow-blow fuse is used where the equipment may draw a brief starting surge, but the circuit still needs protection from a sustained fault. In gate operator service, the fuse should be treated as a protection device, not as the root problem by itself. If it blows repeatedly, the operator needs diagnosis before more fuses are installed.
This part is commonly listed as a 6 amp slow-blow fuse and some references associate it with OSCO SWD gate operator applications. Always match the fuse rating, physical style, and circuit requirement from the wiring diagram or original fuse label.
Compatible With
Commonly associated with these applications when the wiring diagram or parts list specifies 2500-1742:
- Select Linear / OSCO gate operator electrical circuits requiring a 6 amp slow-blow fuse
- OSCO SWD gate operator applications referenced in supplier listings
- Commercial gate operator control or protection circuits where 2500-1742 is listed
- Not a universal fuse for every Linear, OSCO, GTO, or Mighty Mule operator
Features and Specifications
| Manufacturer | Linear / OSCO |
|---|
| Product Type | Slow-blow fuse |
|---|
| Part Number | 2500-1742 |
|---|
| Application | Electrical circuit protection |
|---|
| Fuse Rating | 6 amp |
|---|
| Fuse Type | Slow-blow / time-delay style |
|---|
| Compatible Operator Type | Select Linear / OSCO operators and OSCO SWD applications where specified |
|---|
| Notes | Match fuse rating, style, and wiring diagram before replacement |
|---|
Also Known As / Related Part Numbers
- 2500-1742
- 25001742
- LIN-2500-1742
- LN-25001742
- 6 amp slow-blow fuse
- 6A slo-blo fuse
- 6 amp time-delay fuse
- OSCO SWD fuse reference
Technician Note
If the fuse blows again after replacement, stop and troubleshoot the circuit. Repeated fuse failure usually means another problem exists, such as a short, bad accessory, damaged wiring, motor issue, or incorrect fuse type.
Before Ordering Checklist
- Confirm the original fuse rating is 6 amp slow-blow
- Verify the operator parts list or wiring diagram calls for 2500-1742
- Match the physical fuse size and holder style
- Inspect for damaged wiring, water intrusion, failed accessories, or shorted components
- Never increase the fuse rating to get the operator running
Professional Advisory
Commercial gate operator service parts should be installed with power safely disconnected and the operator secured against movement. For high-voltage wiring, moving gate hazards, or uncertain field conditions, use a qualified gate technician.
Important Ordering Warnings
Do not bypass this fuse or replace it with a higher amp fuse. Doing so can damage the operator and create an electrical safety hazard.
Product Questions and Answers
What does slow-blow mean?
A slow-blow fuse can tolerate a brief startup surge but will open when there is a sustained overcurrent condition.
Is 2500-1742 used on OSCO SWD operators?
Some supplier references list 2500-1742 for OSCO SWD gate operators. Verify the exact operator wiring diagram before ordering.
Can I use a standard fast-acting fuse instead?
Only use the fuse type specified by the operator documentation. A fast-acting fuse may nuisance blow, while the wrong slow-blow fuse can reduce protection.
What if the new fuse blows immediately?
That usually points to a circuit fault, damaged wiring, failed accessory, or other electrical problem that should be diagnosed by a qualified technician.
Can I install a higher amp fuse?
No. Do not increase the fuse rating. Use the specified rating and correct the underlying problem.