AAS / Security Brand 14-RTEHW RTE HW Hardwired Request-to-Exit Station
The Security Brands 14-RTEHW RTE HW is a hardwired request-to-exit station built for locations where a simple physical exit command is preferred over a wireless transmitter or touchless sensor. In a typical gate application, the push button is wired to a compatible exit, open, or request-to-exit input on the gate operator or access controller. The included lockout key switch gives property managers or technicians a way to disable the station when the exit point should not be available. Because the push button is hardwired and does not require its own power, this station is often used where reliability and simple service are more important than app control or wireless convenience. It should be installed as an access command device, not as a replacement for monitored safety sensors, fire access hardware, or code-required exit hardware.
Compatible With
- Gate operators with a compatible hardwired exit/open input
- Access control panels with request-to-exit input terminals
- Post-mounted gate exit stations where conduit wiring is available
- Select Security Brands access control systems when wired to the proper input
- Door or gate systems where a simple contact closure is appropriate
Features and Specifications
| Manufacturer | Security Brands / American Access Systems |
|---|
| Product Type | Hardwired request-to-exit station |
|---|
| Part Number | 14-RTEHW |
|---|
| Mounting Style | Post mount |
|---|
| Application | Hardwired gate or door exit command |
|---|
| Power Requirement | No power required for push-button function |
|---|
| Key Feature | Lockout key switch |
|---|
| Enclosure | Polycarbonate construction |
|---|
| Notes | Direct wiring to a compatible operator or access controller input is required |
|---|
Also Known As / Related Part Numbers
- 14-RTEHW
- RTE HW
- Security Brands 14-RTEHW
- AAS 14-RTEHW
- Hardwired Request-to-Exit Station
- RTE 300 and Ridge RTE are related exit station families but not direct replacements
Technician Note
The 14-RTEHW is simple, but the input it connects to still matters. Use the operator or controller wiring diagram and do not land the switch across monitored safety, fire access, or high-voltage terminals.
Before Ordering
- Confirm a hardwired RTE input is available on the controller or gate operator.
- Verify the post or pedestal mounting location before ordering.
- Check whether the lockout key switch is required for the site.
- Confirm conduit and low-voltage cable routing before installation.
- Do not substitute this for a monitored safety sensor or required emergency release device.
Important Ordering Warnings
- Do not wire to high-voltage terminals.
- Do not use as a replacement for monitored safety equipment.
Professional Advisory
A qualified gate or access control technician should verify the correct low-voltage terminals before wiring an RTE station into a gate operator or door controller.
Product Questions and Answers
Does the 14-RTEHW need power?
The push-button function does not require power, but the connected gate operator or access controller must be wired correctly.
What does the lockout key switch do?
The lockout switch can disable the request-to-exit station when the exit button should not be active.
Is this wireless?
No. The 14-RTEHW is a hardwired request-to-exit station.
Can it be used outdoors?
It is built in a durable polycarbonate post-mount enclosure, but the installation should still be weather-sealed and wired correctly.
Is this a safety device?
No. It is an exit command station, not a monitored gate safety device or photo eye.