BEA 10MATRIXD110, Matrix, Double Unit, 110volt
The BEA 10MATRIXD110 is a dual-loop induction loop detector from the BEA Matrix family. It is built for vehicle detection in industrial, commercial, access control, parking, barrier, and automatic door environments where the control system needs a reliable signal from one or two pavement loops. A dual-loop detector can monitor two loops from one detector module, which is useful on sites that need separate entry and safety loops, exit and presence loops, or directional-style logic depending on the controller and wiring layout. The 10MATRIXD110 version is the 110 to 120 VAC model, so it is mainly selected when the operator cabinet or control panel provides line-voltage detector power instead of low-voltage AC/DC power.
This detector is commonly replaced when a loop input stops responding, vehicles are detected intermittently, loop status indicators do not behave normally, or the original detector has failed after surge, moisture, cabinet damage, or age. Correct replacement matters because Matrix detectors share a similar housing style across several voltage and loop-count versions. A single-loop Matrix detector, a 12-24 volt Matrix detector, or a different 11-pin detector may look close but may not match the power supply or application.
Compatible With
Compatibility should be verified by the original BEA part number, product family, voltage, loop count, cable length, and the equipment wiring diagram. Commonly associated applications include:
- BEA Matrix family dual-loop vehicle detection systems using 110-120 VAC detector power
- Automatic pedestrian door systems using BEA Matrix loop detection for vehicle presence or approach detection
- Commercial gate operators and parking access systems with compatible 11-pin loop detector wiring
- Barrier gate, parking, entry, exit, and safety loop applications requiring a dual-channel detector
- Industrial door and access control panels wired for an 11-pin Matrix detector or compatible Matrix harness
- Applications using one or two inductive loops where the control equipment supports presence or pulse relay outputs
Features & Specifications
| Manufacturer | BEA Sensors |
|---|
| Product Type | Induction loop detector |
|---|
| Part Number | 10MATRIXD110 |
|---|
| Series / Family | BEA Matrix / Matrix-D |
|---|
| Application | Vehicle detection for door, gate, barrier, parking, and industrial access systems |
|---|
| Loop Configuration | Dual loop detector |
|---|
| Power | 110-120 VAC |
|---|
| Connector | 11-pin male Matrix-style plug-in connection |
|---|
| Tuning | Automatic |
|---|
| Presence Time | 1 minute to infinity, depending on setting |
|---|
| Pulse Output | 100 ms or 500 ms |
|---|
| LED Indicators | Green power indicator and red loop status indicators |
|---|
| Frequency Range | 20 kHz to 130 kHz |
|---|
| Sensitivity Range | 0.005% to 0.5% delta L/L |
|---|
| Notes | Verify voltage and loop count before replacing a similar Matrix detector |
|---|
Also Known As / Related Part Numbers
- 10MATRIXD110
- MATRIX-D 110
- Matrix D 110
- BEA Matrix Dual Loop Detector 110V
- 10MATRIXD1224 - related low-voltage dual-loop version, not a direct voltage substitute
- 10MATRIXIIS110 - related 110-120 VAC single-loop version
- 10MATRIXIIS1224 - related 12-24 VAC/VDC single-loop version
- 10MATRIXHARN - related 11-pin Matrix harness
- 70.0262 - related 11-pin DIN rail socket
- 86CP11 - 11-pin male connector reference
Technician Note
When replacing this detector, do not choose by housing shape alone. Confirm the label shows 10MATRIXD110 or a 110-120 VAC dual-loop Matrix detector, then compare the existing socket or harness wiring to the equipment diagram. If the cabinet has loop faults, damaged loop wire, poor grounding, or surge damage, replacing the detector alone may not correct the problem.
Before Ordering
- Confirm the original detector part number is 10MATRIXD110 or an approved 110-120 VAC dual-loop Matrix equivalent.
- Verify the control panel provides 110-120 VAC detector power.
- Confirm the job needs a dual-loop detector, not a single-loop unit.
- Check that the existing wiring uses an 11-pin socket, DIN base, or BEA Matrix harness arrangement.
- Inspect loop wire condition and splice points before assuming the detector is the only failed component.
Important Ordering Warnings
- Do not replace a 12-24 VAC/VDC Matrix detector with this 110-120 VAC model.
- Do not use a single-loop detector when the control system is wired for two independent loop inputs.
- High-voltage cabinet wiring should be handled by a qualified automatic door, gate, or access control technician.
Professional Advisory
Loop detector replacement may involve live control-panel wiring and vehicle safety functions. If the system controls a moving gate, door, or barrier, verify all safety devices and loop functions after service and do not bypass required safety inputs.
Product Questions & Answers
Is the 10MATRIXD110 a single-loop or dual-loop detector?
The 10MATRIXD110 is a dual-loop Matrix detector. It is used when the system needs to monitor one or two inductive loops from a single detector module.
What voltage does this Matrix detector use?
This version uses 110 to 120 VAC power. It should not be substituted for the 12-24 VAC/VDC Matrix version unless the control equipment is rewired and approved for that change.
Can this detector be used for gate and parking loops?
It may be used in compatible gate, parking, barrier, industrial door, and access control systems that are wired for a BEA Matrix dual-loop detector and the correct power supply.
Does this detector use the Matrix harness?
It can be used with compatible Matrix 11-pin socket or harness wiring, including Matrix-style plug-in installations. Always match the wiring diagram before connecting a replacement.
What should be checked if vehicles are not being detected?
Check loop wire continuity, loop splices, detector power, sensitivity settings, relay wiring, and the controller input. A failed loop in the pavement can mimic a bad detector.