BEA 10MICROCONTROL, Microcell Control Box
The BEA 10MICROCONTROL is the control electronics portion of the Microcell safety beam system. In a working Microcell installation, the beam heads create the detection path and the control box interprets that beam signal, provides status indication, and sends the correct output to the automatic door control. When a Microcell-equipped door has unexplained beam faults, no status LED response, or output problems after the beam heads and wiring have been checked, the control box may be the part being replaced.
This control box should be matched to the actual Microcell beam layout in the field. Microcell systems can be configured for single or multi-beam use depending on the version and application. The control box is not a complete door operator and does not replace the automatic door controller. It is one piece of the safety beam circuit, so the installer still needs to verify beam alignment, wiring, power, and relay input behavior at the door control.
Compatible With
This replacement control box is for BEA Microcell automatic pedestrian door safety beam systems. Compatibility depends on the installed Microcell beam heads, cable wiring, and the door controller safety input.
- BEA Microcell safety beam installations on automatic pedestrian doors
- Microcell single-beam systems using compatible BEA beam heads
- Microcell automatic sliding door threshold safety applications
- Microcell automatic swing door guiderail safety applications
- Replacement of failed or damaged Microcell control electronics where the beam heads and wiring match
- Automatic pedestrian door controllers that accept the Microcell control box output through the proper wiring
Features and Specifications
| Manufacturer | BEA Sensors |
|---|
| Product Type | Replacement safety beam control box |
|---|
| Part Number | 10MICROCONTROL |
|---|
| Application | BEA Microcell automatic pedestrian door safety beam systems |
|---|
| Sensor Family | Microcell |
|---|
| Compatible Beam Type | Select BEA Microcell beam heads and configurations |
|---|
| Output | Control box output to compatible automatic door controller |
|---|
| Diagnostics | Status LEDs may be used during troubleshooting and alignment |
|---|
| Notes | Control box only; not a complete automatic door operator or universal sensor kit |
|---|
Also Known As / Related Part Numbers
- 10MICROCONTROL
- Microcell control box
- BEA Microcell controller
- Microcell safety beam control box
- 10MICROCELL1SL related control box
- 10MICROCELL1S related control box
- 10MICROCELL1D related control box
- Microcell One control box
Technician Note
If the Microcell LEDs do not behave as expected, check power, beam wiring, beam alignment, and DIP switch configuration before assuming the control box has failed.
Before Ordering Checklist
- Confirm the existing system is BEA Microcell.
- Match the beam configuration before replacing the control box.
- Inspect beam cables for damage or water intrusion.
- Verify the automatic door controller input and relay wiring.
- Test the full door safety cycle after replacement.
Professional Advisory
Automatic pedestrian door safety circuits should be tested after any control box replacement. If the door does not stop, reopen, or respond correctly when the beam is interrupted, keep the door out of service until a qualified automatic door technician corrects the issue.
Important Ordering Warnings
- This is not a universal photo-eye controller.
- Do not use this part to bypass a failed safety beam system.
Product Questions and Answers
What does the 10MICROCONTROL do?
It interfaces compatible BEA Microcell beam heads with the automatic door controller and provides the output used when a beam is interrupted.
Is this a complete Microcell beam kit?
No. This row is for the Microcell control box. Beam heads, cables, and other components should be confirmed separately.
Can this fix a Microcell beam that will not align?
Only if the control box is the failed part. Alignment problems are often caused by beam position, wiring, damaged heads, or installation movement.
Can this be used with non-BEA beam heads?
It should be used with compatible BEA Microcell components. Do not assume another brand of beam head will work with this control box.
What should be tested after replacement?
Test power, status LEDs, beam interruption, relay output, and the full automatic door safety response before putting the door back into normal service.