Genie GE-113443.0001.S 24V 350W Power Supply
The Genie GE-113443.0001.S is a 24V 350W power supply used with select Genie 24V gate operator service repairs. Genie service documentation lists 113443.0001.S as Power Supply, 24V, 350W, making it the replacement power supply component where the installed operator parts diagram confirms this exact service part.
This is a power supply component, not a complete control box assembly. It should not be confused with the logic board, 24V motor drive PCB, PCB mounts, reset button, buzzer, control enclosure, batteries, solar panel kit, charger wiring, actuator arm, or complete gate operator kit. Match this part by exact part number, operator model, voltage platform, wattage, mounting location, wiring layout, and supplier package contents before ordering.
Primary Use
- Replacement 24V 350W power supply for select Genie gate operator service repairs
- Used where the service parts diagram lists 113443.0001.S as the correct power supply
- Provides power for compatible Genie 24V gate operator control systems where the operator design supports this component
- Service replacement when the original power supply is failed, damaged, water damaged, surge damaged, overheated, or no longer producing proper output
- Used only after batteries, fuses, wiring, line voltage, accessory loads, motor drive board, and logic board condition have been checked
Compatible With
Use this power supply only where the installed Genie operator documentation confirms 113443.0001.S as the correct service part. Do not assume it fits every Genie gate operator or every 24V gate opener.
- Select Genie GLA24V linear actuator swing gate operator service repairs where the parts diagram lists 113443.0001.S
- Select Genie GRSW24V residential swing gate operator service repairs where the parts diagram lists 113443.0001.S
- Select Genie GRSL24V residential slide gate operator service repairs where the installed parts diagram confirms the same 24V 350W power supply
- Repairs where the original power supply is marked, ordered, or cross-referenced as GE-113443.0001.S or 113443.0001.S
- Applications where the control enclosure, power wiring, battery system, motor drive PCB, logic board, fuses, and connector layout match the installed Genie parts diagram
Features and Specifications
| Specification | Details |
| Brand | Genie |
| Part Number | GE-113443.0001.S / 113443.0001.S |
| Service Description | Power Supply, 24V, 350W |
| Product Type | Gate operator power supply |
| Output Platform | 24V system power where specified by Genie documentation |
| Power Rating | 350W |
| Known Genie Model Families | Select GLA24V, GRSW24V, and GRSL24V service repairs where the parts diagram confirms fitment |
| Main Function | Provides power to compatible Genie 24V gate operator electronics and charging/control system where installed as specified |
| Logic Board Included | Do not assume included; the logic board is a separate service part unless specifically listed |
| Motor Drive Board Included | Do not assume included; the 24V motor drive PCB is a separate service part unless specifically listed |
| Batteries Included | Do not assume included; 12V batteries are separate service parts unless the supplier package specifically lists them |
| Solar Panel Included | Not assumed included; solar panel kits and solar wiring kits are separate accessories unless specifically listed |
| Input Wiring | Verify line-voltage input, grounding, fuse protection, and wiring layout against the installed operator documentation before service |
| Setup Required | No programming for the power supply itself; operator status, battery charging, safety inputs, travel, and fault checks may be required after replacement |
| Package Contents | Confirm before ordering; treat as the power supply only unless mounts, screws, wiring harnesses, fuses, labels, instructions, or other electronics are specifically listed |
Important Comparison With Similar Genie Power and Control Parts
Genie gate operator power and control parts are separate service items. Similar symptoms do not always mean the power supply is the failed component. Confirm which part is actually defective before ordering.
- GE-113443.0001.S / 113443.0001.S: 24V 350W power supply for select Genie gate operator service repairs.
- 113440.0001.S: Logic board assembly. This is the operator control board and is not the power supply.
- 113429.0001.S: 24V motor drive PCB assembly. This board controls motor drive output and is not the power supply.
- 113428.0001.S: 24V drive PCB mount. This is a mechanical mount and is not an electronic power component.
- 113292.0001.S: Gate operator PCB mount. This is a mounting/support part and not the power supply.
- 113315.0001.S: 12V 7Ah battery. This is a battery backup component and is not the power supply.
- 113381.0001.S: Related larger 12V battery option. This is not the power supply.
- 113409.0001.S: 20W solar panel kit. This is a charging accessory and not the 24V 350W power supply.
- 113431.0001.S: Control box enclosure. This is the housing and is not a power supply.
- Complete control box assembly: Not the same item. This listing should be treated as the power supply only unless the supplier package confirms a larger assembly.
Also Known As / Related Part Numbers
- GE-113443.0001.S
- 113443.0001.S
- GE1134430001S
- 1134430001S
- Genie GE-113443.0001.S
- Genie 113443.0001.S
- Genie 24V 350W power supply
- Genie gate operator power supply
- Power Supply, 24V, 350W
- 24V power supply for Genie gate operator
- 350W power supply for Genie 24V gate operator
- Gate operator 24V power supply service part
- 113440.0001.S - related logic board assembly, not the same part
- 113429.0001.S - related 24V motor drive PCB assembly, not the same part
- 113428.0001.S - related 24V drive PCB mount, not the same part
- 113292.0001.S - related gate operator PCB mount, not the same part
- 113315.0001.S - related 12V 7Ah battery, not the same part
- 113381.0001.S - related larger battery option, not the same part
- 113409.0001.S - related 20W solar panel kit, not the same part
- 113431.0001.S - related control box enclosure, not the same part
Technician Notes
- Confirm the power supply is the failed part before ordering. A no-power or low-voltage issue can also be caused by bad batteries, blown fuses, damaged wiring, bad line power, a shorted accessory, failed motor drive board, or failed logic board.
- Check the power supply output under load. A supply that shows voltage with no load may still drop out when the operator tries to run.
- Inspect for burned smell, discoloration, swollen components, loose terminals, corrosion, water marks, insect damage, rodent damage, and lightning or surge damage.
- If the power supply failed from water intrusion, correct the enclosure, seals, conduit entries, wire grommets, drainage, and mounting before installing the replacement part.
- If the power supply failed from overload or repeated fuse problems, inspect the motor drive board, actuator motor, gate binding, battery wiring, accessories, locks, relays, and accessory power loads.
- Do not substitute a generic power supply without confirming voltage, wattage, output type, mounting, wiring, terminal layout, safety listing, and operator compatibility.
- Label wiring before removing the old power supply. Power supply wiring may include line-voltage input, ground, 24V output, battery/charging circuits, and control connections depending on the model.
- After replacement, verify proper output, battery charging, battery backup, safety inputs, reset operation, warning devices, accessory power, and full gate operation.
Before Ordering Checklist
- Confirm the exact part number is GE-113443.0001.S or 113443.0001.S.
- Confirm the installed Genie operator model and service parts diagram list 113443.0001.S.
- Confirm you need the 24V 350W power supply, not the logic board, motor drive PCB, battery, solar kit, PCB mount, reset button, buzzer, or control enclosure.
- Confirm the existing power supply output rating, connector layout, mounting location, and wiring layout match the replacement part.
- Check incoming line voltage, fuses, battery voltage, battery disconnect switch, output voltage, accessory loads, and control board status before replacing the power supply.
- Inspect for water intrusion, insects, corrosion, heat damage, lightning damage, loose terminals, rubbed wires, damaged connectors, and shorted accessories.
- Confirm the gate moves freely and that motor overcurrent or mechanical binding did not damage the power system.
- Confirm whether the package includes only the power supply or also includes mounts, screws, wiring harnesses, fuses, labels, instructions, or other control components.
Professional Advisory
Power supply replacement can involve line voltage, grounding, battery power, stored energy, charging circuits, operator electronics, and moving-gate operation. Incorrect diagnosis or wiring can damage the new power supply, damage control boards, create nuisance faults, or create unsafe gate movement. If the system has water intrusion, lightning damage, burned wiring, repeated blown fuses, unknown prior modifications, high accessory load, fire access wiring, or monitored safety-device issues, have the operator inspected by a qualified gate technician or licensed electrical professional where required. Do not bypass monitored photo eyes, safety edges, reset circuits, fuses, grounding, warning devices, battery protection, or operator control safeguards during diagnosis or repair.
Product Q&A
What is Genie GE-113443.0001.S used for?
Genie GE-113443.0001.S is a 24V 350W power supply used with select Genie gate operator service repairs where the parts diagram lists 113443.0001.S.
Is GE-113443.0001.S the same as the logic board?
No. GE-113443.0001.S is the power supply. The logic board is a separate Genie service part and should not be treated as the same component.
Is this the same as the 24V motor drive PCB?
No. The 24V motor drive PCB controls motor output in supported operators. GE-113443.0001.S is the 24V 350W power supply and should not be substituted for the motor drive board.
Which Genie operators use this 24V 350W power supply?
This power supply appears in select Genie 24V gate operator service parts diagrams, including GLA24V and GRSW24V documentation. Always confirm fitment by the installed operator model and parts diagram before ordering.
Can a failed power supply make the gate stop running?
Yes, but a no-run condition can also be caused by weak batteries, blown fuses, bad wiring, failed logic board, failed motor drive board, shorted accessory, safety fault, reset issue, or motor problem.
Does this power supply include batteries or solar parts?
Do not assume batteries, solar panels, solar wiring, fuses, mounts, or wiring harnesses are included. Treat this item as the power supply only unless the supplier package specifically lists additional parts.
What should I check before replacing this power supply?
Check the operator model, part number, incoming power, fuses, grounding, 24V output, battery voltage, charging behavior, accessory loads, wiring, water intrusion, corrosion, and connected boards before replacing the power supply.