Genie GE-GAKRRPE.S Retro-Reflective Photo Eye Kit
The Genie GE-GAKRRPE.S is a retro-reflective photo eye kit for select Genie gate operator applications where the operator documentation lists GAKRRPE.S as the correct monitored external entrapment-protection device. A retro-reflective photo eye uses one powered sensor on one side of the opening and a reflector on the opposite side to return the beam back to the sensor.
This is a safety photo eye kit, not a gate operator, control board, loop detector, vehicle detector, reflector-only replacement, or universal photo eye. Match the part number, wiring style, monitored input type, beam range, mounting layout, and Genie operator documentation before ordering.
Primary Use
- Monitored retro-reflective photo eye kit for select Genie gate operator safety inputs
- Used as an external entrapment-protection device where the Genie operator documentation lists GAKRRPE.S
- Helps protect the gate opening by detecting beam obstruction between the powered sensor and reflector
- Reduces wiring compared with thru-beam photo eyes because only one side of the opening requires powered sensor wiring
- Used for gate safety applications where 2-wire pulsed monitored photo eye operation is supported
Compatible With
Use Genie GE-GAKRRPE.S only where the installed Genie operator manual, accessory chart, or parts documentation confirms GAKRRPE.S as an approved monitored external entrapment device. Do not assume fitment based only on the Genie brand name or because the operator has photo eye terminals.
- Select Genie gate operator applications where GAKRRPE.S is listed as an approved monitored retro-reflective photo eye
- Select Genie residential and commercial gate operator installations with compatible monitored safety inputs
- Applications requiring a 2-wire pulsed monitored photo eye where the operator documentation supports this device type
- Installations where the sensor and reflector can be mounted within the specified range and aligned properly
- Service replacements where the original photo eye kit is marked, ordered, or cross-referenced as GAKRRPE.S or GE-GAKRRPE.S
Features and Specifications
| Specification | Details |
| Brand | Genie |
| Part Number | GE-GAKRRPE.S |
| Genie Reference Number | GAKRRPE.S |
| Product Type | Retro-reflective photo eye kit |
| Safety Device Type | Monitored external entrapment-protection photo eye where supported by the operator |
| Photo Eye Style | Retro-reflective sensor with reflector target |
| Wiring Style | 2-wire pulsed, where listed by Genie documentation |
| Maximum Range | 45 ft where installed and aligned according to Genie documentation |
| Reflector Requirement | Requires proper reflector placement and alignment opposite the sensor |
| Primary Application | Gate operator safety input applications where GAKRRPE.S is specified |
| Package Contents | Confirm before ordering; treat as a retro-reflective photo eye kit unless individual components are specifically listed |
Important Comparison With Similar Photo Eye Parts
Genie and other gate operator photo eye parts can look similar, but monitored status, wiring style, range, reflector size, and operator compatibility can be different. Confirm the exact part number before ordering.
- GE-GAKRRPE.S / GAKRRPE.S: Genie retro-reflective photo eye kit listed with 2-wire pulsed details and 45 ft maximum range for select monitored gate safety applications.
- 112628.0001.S: Genie 1 inch photo eye reflector replacement. This is a reflector-only part and is not the same as the complete GAKRRPE.S photo eye kit.
- 112851.0001.S: Genie 2 inch photo eye reflector replacement. This is also reflector-only and should not be confused with a full photo eye kit.
- Thru-beam photo eyes: Use a separate transmitter and receiver across the opening. They are not the same as retro-reflective photo eyes.
- Non-monitored photo eyes: May not satisfy monitored safety input requirements on UL 325 gate operators. Do not substitute without confirming the operator documentation.
- Vehicle loops or exit probes: Not the same part. Loops and probes detect vehicles for exit, presence, or shadow functions, while this photo eye is used for beam-based obstruction detection.
Also Known As / Related Part Numbers
- GE-GAKRRPE.S
- GAKRRPE.S
- GEGAKRRPES
- GAKRRPES
- Genie GE-GAKRRPE.S
- Genie GAKRRPE.S
- Genie retro-reflective photo eye kit
- Genie 2-wire pulsed photo eye
- Genie monitored retro-reflective photo eye
- Kit, Photo-Eye, Retro-Reflective, Genie
- Retro-reflective photoeye kit for Genie gate operators
- 112628.0001.S - related 1 inch reflector-only replacement, not the same complete kit
- 112851.0001.S - related 2 inch reflector-only replacement, not the same complete kit
Technician Notes
- Confirm the installed operator supports GAKRRPE.S before replacing or adding this photo eye. Monitored safety inputs are not all wired or programmed the same way.
- Do not replace a monitored Genie photo eye with a non-monitored generic sensor unless the operator documentation specifically allows it.
- Retro-reflective photo eyes depend heavily on alignment. A slightly shifted reflector, loose bracket, dirty lens, sun glare, water intrusion, or damaged reflector can cause a gate to hold open, reverse, or show a safety fault.
- Check the sensor face and reflector before replacing parts. Dirt, spider webs, irrigation residue, condensation, cracked reflector material, and impact damage are common field issues.
- Inspect the wiring path for pinched conductors, water-filled conduit, corroded splices, loose terminals, and incorrect input wiring.
- Confirm whether the operator safety input expects open-direction, close-direction, or other monitored entrapment protection. The device must be assigned and wired to the correct function.
- Do not bypass photo eyes, monitored safety edges, inherent entrapment protection, or gate operator safety circuits to force the gate to run.
Before Ordering Checklist
- Confirm the exact part number is GE-GAKRRPE.S or GAKRRPE.S.
- Confirm the installed Genie operator documentation lists GAKRRPE.S as an approved monitored photo eye.
- Confirm the operator safety input supports 2-wire pulsed monitored photo eye wiring.
- Confirm the opening width is within the listed 45 ft range and that the sensor and reflector can be mounted securely.
- Confirm whether you need the full photo eye kit or only a replacement reflector.
- Inspect the existing photo eye, reflector, brackets, wiring, conduit, splices, and operator safety input before ordering.
- Confirm the issue is not caused by alignment, dirt, moisture, sun glare, damaged cable, loose terminals, or incorrect operator programming.
- Confirm package contents before assuming reflector, brackets, screws, wire, hood, mounting hardware, or installation accessories are included.
Professional Advisory
Photo eyes are part of the gate operator safety system and should not be bypassed, jumped out, or treated as optional. Incorrect installation can create unsafe gate movement or prevent the operator from meeting monitored entrapment-protection requirements. If the installation involves monitored safety inputs, multiple entrapment zones, relay wiring, unknown prior modifications, fire access equipment, or a gate that will not close because of a safety fault, use a qualified gate operator technician.
Product Q&A
What is Genie GE-GAKRRPE.S used for?
Genie GE-GAKRRPE.S is a retro-reflective photo eye kit used with select Genie gate operators where GAKRRPE.S is listed as the correct monitored external entrapment-protection device.
Is GE-GAKRRPE.S the same as a reflector-only replacement?
No. GE-GAKRRPE.S should be treated as a retro-reflective photo eye kit. Genie reflector-only parts, such as 112628.0001.S or 112851.0001.S, are related replacement reflectors and are not the same as the complete photo eye kit.
What is the range of the Genie GAKRRPE.S photo eye?
Genie documentation lists GAKRRPE.S with a 45 ft maximum range. Actual performance depends on proper alignment, clean lenses, secure mounting, reflector condition, wiring, sunlight exposure, and site conditions.
Does this photo eye work with every Genie gate operator?
No. Use this kit only where the Genie operator manual, accessory chart, or parts documentation confirms GAKRRPE.S as an approved monitored photo eye for that operator and safety input.
Is this a thru-beam photo eye?
No. GE-GAKRRPE.S is a retro-reflective photo eye kit. It uses a powered sensor on one side and a reflector on the opposite side, instead of a separate powered transmitter and receiver pair.
Can I bypass this photo eye if the gate will not close?
No. Do not bypass monitored photo eyes or other gate safety devices. If the gate will not close, check alignment, reflector condition, wiring, water intrusion, operator settings, and safety input status or call a qualified gate technician.
What should I check before replacing the photo eye kit?
Check the part number, operator compatibility, 2-wire pulsed safety input, sensor alignment, reflector condition, mounting brackets, wiring, conduit, moisture, sun glare, and operator fault codes before replacing the kit.