Genie GE-GAKTBPE.S Thru-Beam Photo Eye Kit
The Genie GE-GAKTBPE.S is a thru-beam photo eye kit for select Genie gate operator applications where the operator documentation lists GAKTBPE.S as the correct monitored external entrapment-protection device. A thru-beam photo eye uses a separate transmitter and receiver mounted across the gate opening, so both sides of the opening must be wired and aligned correctly.
This is a safety photo eye kit, not a gate operator, control board, loop detector, vehicle detector, exit probe, retro-reflective sensor, reflector-only replacement, or universal photo eye. Match the part number, wiring style, monitored input type, beam range, mounting layout, and Genie operator documentation before ordering.
Primary Use
- Monitored thru-beam photo eye kit for select Genie gate operator safety inputs
- Used as an external entrapment-protection device where the Genie operator documentation lists GAKTBPE.S
- Provides a beam across the gate opening using a separate transmitter and receiver
- Used for gate safety applications where 2-wire pulsed monitored photo eye operation is supported
- Commonly used when a thru-beam sensor layout is preferred over a retro-reflective sensor and reflector layout
Compatible With
Use Genie GE-GAKTBPE.S only where the installed Genie operator manual, accessory chart, or parts documentation confirms GAKTBPE.S as an approved monitored external entrapment device. Do not assume fitment based only on the Genie brand name or because the operator has photo eye terminals.
- Select Genie gate operator applications where GAKTBPE.S is listed as an approved monitored thru-beam photo eye
- Select Genie residential and commercial gate operator installations with compatible monitored safety inputs
- Applications requiring a 2-wire pulsed monitored photo eye where the operator documentation supports this device type
- Installations where both the transmitter and receiver can be mounted, wired, and aligned across the opening
- Service replacements where the original photo eye kit is marked, ordered, or cross-referenced as GAKTBPE.S or GE-GAKTBPE.S
Features and Specifications
| Specification | Details |
| Brand | Genie |
| Part Number | GE-GAKTBPE.S |
| Genie Reference Number | GAKTBPE.S |
| Product Type | Thru-beam photo eye kit |
| Safety Device Type | Monitored external entrapment-protection photo eye where supported by the operator |
| Photo Eye Style | Thru-beam transmitter and receiver |
| Wiring Style | 2-wire pulsed, where listed by Genie documentation |
| Maximum Range | 49 ft where installed and aligned according to Genie documentation |
| Alignment Requirement | Requires proper alignment between transmitter and receiver across the gate opening |
| Primary Application | Gate operator safety input applications where GAKTBPE.S is specified |
| Package Contents | Confirm before ordering; treat as a thru-beam photo eye kit unless individual components are specifically listed |
Important Comparison With Similar Photo Eye Parts
Genie and other gate operator photo eye parts can look similar, but monitored status, wiring style, range, reflector use, and operator compatibility can be different. Confirm the exact part number before ordering.
- GE-GAKTBPE.S / GAKTBPE.S: Genie thru-beam photo eye kit listed with 2-wire pulsed details and 49 ft maximum range for select monitored gate safety applications.
- GE-GAKRRPE.S / GAKRRPE.S: Genie retro-reflective photo eye kit. This uses a sensor and reflector, not a separate transmitter and receiver pair.
- 113392.0001.S / IRB-MON2: Related monitored thru-beam style photo eye option listed in Genie documentation, but not the same part number as GAKTBPE.S.
- OPAKPEN4GX.S / OSE-S-1512: Related thru-beam style photo eye option listed in Genie documentation, but not the same Genie GAKTBPE.S kit.
- Reflector-only parts: Not used the same way as a thru-beam kit. Thru-beam photo eyes use a transmitter and receiver, not a reflector target.
- Non-monitored photo eyes: May not satisfy monitored safety input requirements on UL 325 gate operators. Do not substitute without confirming the operator documentation.
- Vehicle loops or exit probes: Not the same part. Loops and probes detect vehicles for exit, presence, or shadow functions, while this photo eye is used for beam-based obstruction detection.
Also Known As / Related Part Numbers
- GE-GAKTBPE.S
- GAKTBPE.S
- GEGAKTBPES
- GAKTBPES
- Genie GE-GAKTBPE.S
- Genie GAKTBPE.S
- Genie thru-beam photo eye kit
- Genie 2-wire pulsed thru-beam photo eye
- Genie monitored thru-beam photo eye
- Kit, Photo-Eye, Thru Beam, Genie
- Thru-beam photoeye kit for Genie gate operators
- GAKRRPE.S - related Genie retro-reflective photo eye kit, not the same thru-beam kit
- 113392.0001.S - related EMX IRB-MON2 thru-beam option, not the same Genie GAKTBPE.S kit
- OPAKPEN4GX.S - related CEDES thru-beam option, not the same Genie GAKTBPE.S kit
Technician Notes
- Confirm the installed operator supports GAKTBPE.S before replacing or adding this photo eye. Monitored safety inputs are not all wired or programmed the same way.
- Do not replace a monitored Genie photo eye with a non-monitored generic sensor unless the operator documentation specifically allows it.
- Thru-beam photo eyes require wiring to both sides of the gate opening. Check conduit, splices, terminals, and cable protection on both the transmitter and receiver sides.
- Alignment is critical. A shifted post, loose bracket, gate vibration, dirt, sun glare, water intrusion, or damaged lens can cause safety faults, nuisance reversing, or a gate that will not close.
- Confirm whether the operator safety input expects close-direction, open-direction, or another monitored entrapment protection function. The device must be wired and assigned to the correct safety input.
- If the operator is running on solar or battery backup, verify how the safety devices are powered during gate activation according to the operator manual.
- Do not bypass photo eyes, monitored safety edges, inherent entrapment protection, or gate operator safety circuits to force the gate to run.
Before Ordering Checklist
- Confirm the exact part number is GE-GAKTBPE.S or GAKTBPE.S.
- Confirm the installed Genie operator documentation lists GAKTBPE.S as an approved monitored photo eye.
- Confirm the operator safety input supports 2-wire pulsed monitored photo eye wiring.
- Confirm the opening width is within the listed 49 ft range and that both sides can be wired and aligned securely.
- Confirm whether you need a thru-beam kit or a retro-reflective photo eye kit.
- Inspect the existing transmitter, receiver, brackets, wiring, conduit, splices, and operator safety input before ordering.
- Confirm the issue is not caused by alignment, dirt, moisture, sun glare, damaged cable, loose terminals, or incorrect operator programming.
- Confirm package contents before assuming hoods, brackets, screws, wire, mounting hardware, or installation accessories are included.
Professional Advisory
Photo eyes are part of the gate operator safety system and should not be bypassed, jumped out, or treated as optional. Incorrect installation can create unsafe gate movement or prevent the operator from meeting monitored entrapment-protection requirements. If the installation involves monitored safety inputs, multiple entrapment zones, relay wiring, unknown prior modifications, fire access equipment, or a gate that will not close because of a safety fault, use a qualified gate operator technician.
Product Q&A
What is Genie GE-GAKTBPE.S used for?
Genie GE-GAKTBPE.S is a thru-beam photo eye kit used with select Genie gate operators where GAKTBPE.S is listed as the correct monitored external entrapment-protection device.
Is GE-GAKTBPE.S the same as GE-GAKRRPE.S?
No. GE-GAKTBPE.S is a thru-beam photo eye kit with a separate transmitter and receiver. GE-GAKRRPE.S is a retro-reflective photo eye kit that uses a sensor and reflector.
What is the range of the Genie GAKTBPE.S photo eye?
Genie documentation lists GAKTBPE.S with a 49 ft maximum range. Actual performance depends on proper alignment, clean lenses, secure mounting, wiring condition, sunlight exposure, and site conditions.
Does this photo eye work with every Genie gate operator?
No. Use this kit only where the Genie operator manual, accessory chart, or parts documentation confirms GAKTBPE.S as an approved monitored photo eye for that operator and safety input.
Is this a retro-reflective photo eye?
No. GE-GAKTBPE.S is a thru-beam photo eye kit. It uses a separate transmitter and receiver mounted across the opening, not a sensor aimed at a reflector.
Can I bypass this photo eye if the gate will not close?
No. Do not bypass monitored photo eyes or other gate safety devices. If the gate will not close, check alignment, wiring, water intrusion, operator settings, input configuration, and safety fault status or call a qualified gate technician.
What should I check before replacing the photo eye kit?
Check the part number, operator compatibility, 2-wire pulsed safety input, transmitter and receiver alignment, mounting brackets, wiring, conduit, moisture, sun glare, and operator fault codes before replacing the kit.