NICE Apollo 10055090 1050 Control Board Retrofit Bracket Kit for 11111B Control Box
The 10055090 retrofit bracket kit is a small but important mounting hardware kit used during certain Apollo control-board upgrades. When an older Apollo gate operator enclosure is being converted to accept a 1050 series controller, the original board standoffs and hole pattern may not line up with the newer board. This kit provides the brackets and screws needed to position and secure the 1050 board so it is not loose inside the cabinet and does not rely on improvised mounting. It is commonly used in 11111B style control boxes and older Apollo control box layouts where a 600 or 800 series board has been removed and a 1050 controller is being installed as part of a service repair or modernization.
This is a fitment-sensitive gate operator service part. Match the part number, operator family, control box style, hardware style, and installed system layout before ordering. Similar NICE Apollo parts may look close in photos but can differ by mounting hole pattern, actuator generation, board revision, safety monitoring requirement, or included hardware.
Compatible With
- NICE Apollo 1050 control board retrofit installations
- 11111B metal control box applications when used with the correct board and hardware
- Older Apollo 600 series board standoff layouts when being updated to a 1050 board
- Older Apollo 800 series board standoff layouts when being updated to a 1050 board
- Select Apollo swing and slide gate operator systems being converted to 1050 control, when confirmed by the operator parts diagram and system requirements
Features & Specifications
| Manufacturer | NICE Apollo |
|---|
| Product Type | Control board retrofit mounting bracket kit |
|---|
| Part Number | 10055090 |
|---|
| Application | Mounting a 1050 controller in compatible Apollo control boxes |
|---|
| Compatible Operator Type | Select Apollo swing and slide operators using compatible 1050 control upgrades |
|---|
| Included Components | Retrofit brackets and mounting screws |
|---|
| Notes | Control board and control box are not included |
|---|
Also Known As / Related Part Numbers
- 10055090
- NICE-10055090
- 1050RFK
- 1050 retrofit kit
- Apollo 1050 brackets and screws
- 1050 control board retrofit brackets
- 11111B 1050 mounting bracket kit
Technician Note
- Use this kit to secure the board, not to change operator voltage or make an incompatible board work.
- If the original control box is damaged, corroded, or too crowded, replacing the enclosure may be a better repair than retrofitting into a poor cabinet.
- A 1050 board upgrade may also require safety-device review and wiring cleanup before the gate is placed back in service.
Before Ordering Checklist
- Confirm the installed control box is a compatible 11111B or older Apollo enclosure layout.
- Confirm the replacement board is a 1050 series board.
- Inspect existing standoffs and enclosure condition before reusing the cabinet.
- Check whether monitored entrapment protection is required for the upgraded control board.
- Verify all accessories and operator wiring are compatible with the new board before powering the system.
Professional Advisory
Gate operators can involve stored force, moving gate hardware, low-voltage accessories, battery systems, and line-voltage power inside the control box. Do not bypass monitored safety devices or operate a gate with unsafe movement. For control-board replacement, electrical troubleshooting, welding, or unknown wiring conditions, use a qualified gate technician.
Product Questions & Answers
Does the 10055090 kit include the 1050 control board?
No. The 10055090 kit is the retrofit bracket and screw kit used to mount a 1050 board. The control board is sold separately unless your listing specifically states otherwise.
What control box is this retrofit kit commonly used with?
It is commonly associated with 11111B Apollo metal control boxes and older 600 or 800 series board standoff layouts being updated for a 1050 controller.
Can this kit make any Apollo operator compatible with a 1050 board?
No. It only solves the mounting problem. The operator, power system, accessories, safety devices, and wiring must still be compatible with the selected 1050 board.
Why should the board be mounted with the correct bracket kit?
A loose or poorly mounted control board can stress wires, touch the enclosure, and create intermittent faults. The correct bracket kit keeps the board secure inside the cabinet.
Should a technician handle a 1050 board retrofit?
A qualified gate technician is recommended when the job involves control-board replacement, rewiring, safety-device updates, or uncertain operator history.