Transmitter Solutions 295SEPC1V Stingray 295 MHz CLIKcard Compatibility Details
The Transmitter Solutions TRARAY295SEPC1V is the Gate Openers Unlimited catalog SKU for the Stingray transmitter identified by Transmitter Solutions as model 295SEPC1V. This is a programmable one-button visor transmitter operating at 295 MHz for compatible Sentex CLIKcard and access control radio applications.
Transmitter Solutions specifically identifies the 295SEPC1V as compatible with the Sentex CLIKcard-1 transmitter application. The transmitter uses a factory-set sequence number and facility code that must be programmed into compatible system memory. It is not a DIP-switch transmitter.
What This Transmitter Does
The 295SEPC1V sends an individually numbered 295 MHz wireless credential to a compatible receiver. The one-button model provides Button A for the authorized function assigned by the installed receiver or access control system.
The receiver determines what Button A operates. Depending on the properly configured access system, the transmitter may activate an authorized gate, door, or other access control function.
Matching 295 MHz frequency and one button alone does not establish compatibility. The receiver must also support the applicable CLIKcard-compatible protocol and transmitter credential format.
All Verified Compatibility and Applications
- Sentex CLIKcard-1 transmitter applications.
- Transmitter Solutions HIVE Wiegand Receiver in the compatible 295 MHz configuration.
- Compatible 295 MHz programmable telephone entry systems using the supported CLIKcard-compatible transmitter protocol.
- Compatible 295 MHz security systems using the supported CLIKcard-compatible transmitter protocol.
- Compatible 295 MHz access control systems using the supported CLIKcard-compatible transmitter protocol.
Sentex CLIKcard-1 Compatibility
The current Transmitter Solutions product page and exact 295SEPC1V model cut sheet specifically identify Sentex CLIKcard-1 compatibility.
The Stingray 295SEPC1V is a Transmitter Solutions product using a CLIKcard-compatible protocol. It should not be represented as the same physical or packaged transmitter as an original Sentex CLIKcard-1. The verified relationship is compatibility with the documented CLIKcard-1 transmitter application.
Do not identify a replacement by the Sentex name, gray button, or 295 MHz frequency alone. Verify the original transmitter and installed receiver before ordering.
HIVE Wiegand Receiver Compatibility
Transmitter Solutions documents its HIVE Wiegand Receiver in 295 MHz, 318 MHz, and 433 MHz configurations. The manufacturer receiver cut sheet identifies Sentex compatibility and lists Stingray 295 MHz transmitters as supported accessories.
The installed HIVE Wiegand Receiver must use the compatible 295 MHz configuration for a 295SEPC1V transmitter. A 318 MHz or 433 MHz receiver is not a frequency match.
The 295SEPC1V transmitter does not have a wired Wiegand output. It sends the wireless 295 MHz credential to the compatible receiver. The HIVE Wiegand Receiver provides the wired Wiegand connection to the telephone entry or access control equipment.
HIVE Dual Frequency Wiegand Receiver Considerations
The Transmitter Solutions HIVE Dual Frequency Wiegand Receiver manual documents a configurable 295 MHz radio frequency card using Sentex protocol. The receiver uses plug-in radio cards and supports selectable 26-bit or 30-bit Wiegand output.
The dual-frequency receiver documentation does not individually list 295SEPC1V by exact model number. For an existing HIVE Dual Frequency installation, verify that the correct 295 MHz Sentex protocol radio card is installed before ordering the transmitter.
The receiver manual also documents facility-code checking. Confirm the receiver credential configuration and connected access control system before replacing transmitters at an HOA, apartment, parking, or commercial property.
Manufacturer 26-Bit and 30-Bit Receiver Documentation
The exact 295SEPC1V cut sheet describes the transmitter for Wiegand 26-bit programmable telephone entry, security, and access control system applications operating with a 295 MHz input.
The Stingray 295SEPC transmitter manual also states that each individually numbered transmitter can be used with a compatible receiver capable of receiving the documented 26-bit input and an access control system equipped with the same protocol.
The current HIVE Wiegand Receiver product page separately lists 295 MHz at 30 bits, while the receiver cut sheet states compatibility with 26-bit devices. The HIVE Dual Frequency Wiegand Receiver manual documents selectable 26-bit or 30-bit Wiegand output.
Because the receiver documentation uses different Wiegand output descriptions, verify the exact receiver model and connected access control panel format. Do not assume the transmitter itself connects directly to a Wiegand input.
Factory-Set Facility Code and Sequence Number
The Transmitter Solutions Stingray manual states that each 295SEPCxV transmitter is manufactured and sold with a different factory-set sequence number and facility code.
The transmitter facility code and sequence number must be programmed into compatible system memory. This is different from opening a fixed-code remote and copying DIP-switch positions.
The manufacturer documents a 16-bit security code providing 65,536 code combinations and a 6-bit facility-code field providing 64 facility-code combinations.
The current Transmitter Solutions product page also states that facility codes 30, 31, 32, and 33 are available on all models. For a managed property or transmitter batch, confirm the required facility code before ordering.
A transmitter can operate at the correct 295 MHz frequency and still fail to activate the system if its facility code or individual sequence number has not been authorized in the receiver or access control database.
295 MHz Range and Radio Performance
The manufacturer documents 295 MHz operation with AM/ASK modulation and a free-space transmitter range of 60 to 120 yards. Actual installed range can be lower because of receiver antenna placement, metal gate operator cabinets, buildings, radio interference, and other site conditions.
If an existing transmitter suddenly operates only from close to the receiver, check the 23A battery and receiver antenna condition before assuming the transmitter model or protocol is incorrect.
One-Button Stingray Configuration
The Transmitter Solutions 295SEPC transmitter manual identifies two Stingray visor models:
- 295SEPC1V - one-button Stingray transmitter with Button A.
- 295SEPC2V - two-button Stingray transmitter with Buttons A and B.
The exact 295SEPC1V is the one-button version. Confirm that the installation requires only the authorized Button A function before replacing a two-button transmitter with this model.
Button and Enclosure Color Documentation
The current Transmitter Solutions product page identifies the transmitter color as gray. The exact model cut sheet identifies one gray button. The transmitter family manual more specifically labels Button A as dark gray and the enclosure as light gray.
These manufacturer descriptions are generally consistent with the illustrated transmitter but should not be used as the primary compatibility check. Verify the complete 295SEPC1V model number, 295 MHz frequency, and CLIKcard-compatible receiver system.
Similar Parts Are Not Automatically Interchangeable
295SEPC2V is the related two-button Stingray visor transmitter. Transmitter Solutions identifies that model with Sentex CLIKcard-2 compatibility. Do not substitute the one-button 295SEPC1V when a second transmitter function is required.
295SEPC1K-C is a Monarch one-button 295 MHz keychain transmitter documented for Sentex CLIKcard-1K compatibility. It is a separate transmitter family and exact compatibility reference. Do not automatically treat CLIKcard-1 and CLIKcard-1K as identical replacement applications.
The Monarch keychain model also uses a different battery system. The Stingray 295SEPC1V uses one 12V type 23A alkaline battery.
295SEPA1V is a separate Stingray 295 MHz transmitter documented for Sentex AUTOkey-1 compatibility. The SEPC and SEPA suffixes identify different transmitter protocol applications. Do not substitute the AUTOkey-compatible SEPA model for the CLIKcard-compatible SEPC model based only on frequency and one-button appearance.
318 MHz, 418 MHz, 433 MHz, and other-frequency Stingray transmitters are not replacements for the 295SEPC1V. DIP-switch transmitters are also not automatic replacements for this programmable credential transmitter.
Features and Specifications
| Feature | Specification |
| Brand | Transmitter Solutions |
| Product Family | Stingray |
| Catalog SKU | TRARAY295SEPC1V |
| Manufacturer Model | 295SEPC1V |
| Product Type | Programmable wireless visor transmitter |
| Operating Frequency | 295 MHz |
| Number of Buttons | 1 |
| Button Identification | Button A |
| Button Color | Gray on exact cut sheet; dark gray in transmitter family manual |
| Enclosure Color | Light gray per transmitter family manual |
| Mounting Style | Visor transmitter |
| Protocol | CLIKcard compatible |
| Verified Compatibility | Sentex CLIKcard-1 transmitter application |
| Verified Transmitter Solutions Receiver | HIVE Wiegand Receiver in compatible 295 MHz configuration |
| Related Configurable Receiver Platform | HIVE Dual Frequency Wiegand Receiver with documented 295 MHz Sentex protocol radio configuration; verify installed radio card |
| Programming Type | Programmable into compatible system memory |
| Transmitter Numbering | Factory-set sequence number and facility code |
| Security Code | 16-bit security code per transmitter manual |
| Code Combinations | 65,536 |
| Facility Codes | 64 combinations per transmitter manual; current product page states FC 30, 31, 32, and 33 available on all models |
| System Format Documentation | 26-bit transmitter application language; HIVE receiver documentation also identifies 30-bit 295 MHz and selectable 26-bit or 30-bit receiver output configurations |
| Modulation | AM / ASK |
| Rated ERP | 50 to 100 mW per transmitter manual |
| Battery | 1 x 12V type 23A alkaline battery |
| Documented Battery Life | 12 to 18 months |
| Current Consumption | 20 mA |
| Documented Free-Space Range | 60 to 120 yards |
| Operating Temperature | -4 F to 131 F (-20 C to 55 C) |
| Overall Dimensions | 3.26 x 1.88 x 0.62 inches |
| Weight | 1 oz. (20 g) |
| FCC ID | SU7295SEPCV |
| Warranty | 60 months from transmitter manufacturing date per manufacturer manual |
Manufacturer Cut Sheet Filename Note
The current Transmitter Solutions product page links to a cut sheet file whose filename includes "295SSEPC1V." The content of that official document identifies the product itself as Model 295SEPC1V and repeatedly states Sentex CLIKcard-1 compatibility.
Use 295SEPC1V as the product model number. Do not add the extra "S" from the document filename to the transmitter part number.
Also Known As and Related Product References
- TRARAY295SEPC1V - Gate Openers Unlimited catalog SKU.
- 295SEPC1V - Transmitter Solutions manufacturer model.
- Stingray 295SEPC1V.
- Sentex CLIKcard-1 - manufacturer-identified compatible transmitter application.
- 295SEPC2V - related two-button Stingray visor transmitter documented for Sentex CLIKcard-2 compatibility.
- 295SEPC1K-C - separate Monarch keychain transmitter documented for Sentex CLIKcard-1K compatibility.
- 295SEPA1V - separate Stingray 295 MHz AUTOkey-1 compatible transmitter.
- HIVE Wiegand Receiver - manufacturer-documented receiver listing Stingray 295 MHz transmitter support in its 295 MHz configuration.
- HIVE Dual Frequency Wiegand Receiver - configurable receiver platform documenting a 295 MHz Sentex protocol radio configuration; verify installed radio card and output format.
- SU7295SEPCV - FCC ID documented in the Stingray 295SEPC transmitter manual.
Package and Battery Check
The manufacturer specifies one 12V type 23A alkaline battery as the transmitter power source and identifies the product as a visor model. Current public manufacturer documentation does not clearly list every retail package component or specifically confirm a fresh battery or separate visor mounting accessory in every package. Confirm current package contents when those items are specifically required.
Technician Note
The biggest ordering mistake with the 295SEPC1V is matching only "295 MHz" and "1 button." Check the SEPC suffix and CLIKcard-1 protocol. The similar 295SEPA1V is an AUTOkey-1 compatible transmitter and is not an automatic replacement. The Monarch 295SEPC1K-C is documented for CLIKcard-1K and is also a different keychain product. Match the original transmitter, receiver frequency, protocol, facility code, and credential requirements before ordering.
Before Ordering Checklist
- Verify the exact manufacturer model 295SEPC1V.
- Confirm the Gate Openers Unlimited catalog SKU TRARAY295SEPC1V.
- Do not add the extra "S" found in the official cut sheet filename to the product model.
- Confirm the installed radio receiver operates at 295 MHz.
- Verify Sentex CLIKcard-1 compatibility when replacing that documented transmitter application.
- Record the exact installed receiver or access control system model.
- For a HIVE Wiegand Receiver, confirm the compatible 295 MHz configuration.
- For a HIVE Dual Frequency Wiegand Receiver, verify the documented 295 MHz Sentex protocol radio card or configuration.
- Confirm the receiver Wiegand output matches the connected access control equipment.
- Confirm the required facility code.
- Confirm the factory-set sequence-number or transmitter credential requirements.
- Confirm one physical transmitter button is required.
- Verify the application requires only the Button A function.
- Do not use DIP-switch programming instructions.
- Do not substitute the 295SEPA1V AUTOkey-compatible transmitter for the 295SEPC1V.
- Do not assume 295SEPC1K-C is the same replacement because it is a separate keychain transmitter documented for CLIKcard-1K.
- Do not identify compatibility by gray housing or button color alone.
- Confirm current package contents when battery or visor accessory inclusion is important.
Programming and Service Notes
The transmitter facility code and factory-set sequence number must be programmed into compatible system memory. Use the enrollment procedure for the exact installed receiver, telephone entry system, or access control platform.
Do not attempt to program the 295SEPC1V by copying DIP-switch positions. The transmitter does not use a DIP-switch code bank.
The manufacturer specifies one 12V type 23A alkaline battery. Battery access is through the sliding battery door. Install the battery with the polarity shown in the transmitter enclosure. The red LED should illuminate when Button A is pressed.
If the transmitter LED does not illuminate, the manufacturer troubleshooting information directs the user to replace the transmitter battery. If the LED is on but the system does not receive the transmitter signal, verify that the transmitter has been programmed into the system. Reduced operating range is also a manufacturer-listed reason to replace the battery.
If short range continues with a known-good battery, inspect the receiver antenna location and radio environment. Metal enclosures and radio interference can reduce operating range.
Professional Advisory
Do not bypass photo eyes, monitored safety edges, entrapment protection, emergency access, fire access, garage door reversal systems, or operator safety circuits while troubleshooting a transmitter or receiver problem. Unclear receiver wiring, Wiegand interfaces, gate operator inputs, or access control electrical faults should be inspected by a qualified gate, garage door, or access control technician.
Product Questions and Answers
Is TRARAY295SEPC1V the same transmitter model as 295SEPC1V?
TRARAY295SEPC1V is the Gate Openers Unlimited catalog SKU, while Transmitter Solutions identifies the Stingray transmitter itself as model 295SEPC1V. Verify the exact 295 MHz model and installed receiver before ordering.
Is the Stingray 295SEPC1V compatible with Sentex CLIKcard-1 applications?
Yes. The current Transmitter Solutions product page and exact 295SEPC1V cut sheet specifically identify Sentex CLIKcard-1 compatibility. Verify the installed 295 MHz receiver and transmitter credential requirements before adding or replacing a remote.
Does the TRARAY295SEPC1V use DIP switches?
No. The 295SEPC1V is a programmable transmitter with a factory-set facility code and sequence number. That credential information must be programmed into compatible system memory.
Is the 295SEPC1V compatible with the Transmitter Solutions HIVE Wiegand Receiver?
Transmitter Solutions lists Stingray 295 MHz transmitters as supported accessories for the HIVE Wiegand Receiver and identifies Sentex compatibility. The installed receiver must use the compatible 295 MHz configuration and its Wiegand output must match the connected access control equipment.
Can the 295SEPC1V be used with a HIVE Dual Frequency Wiegand Receiver?
The HIVE Dual Frequency Wiegand Receiver manual documents a 295 MHz Sentex protocol radio configuration. Verify that the correct 295 MHz radio card is installed and that the receiver's selectable 26-bit or 30-bit Wiegand output matches the connected access control system.
What battery and range are documented for the Stingray 295SEPC1V?
The manufacturer specifies one 12V type 23A alkaline battery with documented battery life of approximately 12 to 18 months. The cut sheet and transmitter manual list a free-space range of 60 to 120 yards, although actual range can be reduced by antenna placement, structures, and radio interference.
Is the 295SEPA1V AUTOkey transmitter the same as the 295SEPC1V CLIKcard transmitter?
No. The 295SEPC1V is documented for Sentex CLIKcard-1 compatibility, while the 295SEPA1V is documented for Sentex AUTOkey-1 compatibility. The SEPC and SEPA suffixes identify different transmitter applications and should not be substituted based only on 295 MHz frequency and one button.
What should I check if the 295SEPC1V LED lights but the gate or access system does not respond?
Verify that the transmitter facility code and sequence number have been programmed into the compatible system and confirm the receiver uses the correct 295 MHz CLIKcard-compatible protocol. If enrollment and compatibility are correct, receiver antenna, interference, wiring, or access control system problems may require diagnosis by a qualified technician.