The HySecurity MX001725 is a replacement 5HP, 60Hz, single-phase electric motor for select HySecurity and Nice HySecurity hydraulic gate operator systems. It is commonly listed as Motor, Electric, 60Hz, 5 hp, 1PH, 3450 RPM, 230VAC and is also shown in current listings with 208-230VAC / 230VAC voltage references.
This motor is part of the electric-to-hydraulic drive system used in compatible HySecurity operators. In a hydraulic gate operator, the electric motor drives the hydraulic pump so the pump pack can build pressure and move hydraulic fluid through the valves, hoses, manifolds, and hydraulic drive components. A 5HP motor is typically used in higher-load applications where the hydraulic system requires more power than smaller 1HP, 2HP, or DC motor configurations.
The MX001725 should be matched by HySecurity part number, operator model, serial number, motor nameplate, voltage, phase, frequency, horsepower, RPM, frame/mounting style, shaft/coupler arrangement, pump pack layout, and wiring. Do not order by 5HP motor alone. Similar motors may not match the HySecurity pump, coupler, capacitor circuit, mounting, controller output, or duty requirements.
What This Motor Does
The MX001725 electric motor provides the rotation needed to drive the hydraulic pump in compatible HySecurity hydraulic gate operators. The pump then supplies the pressure and flow needed for the operator to move the gate or hydraulic drive assembly, depending on the operator family and installation.
This is the electric motor only unless the current package specifically includes additional parts. It is not a complete pump pack, hydraulic motor, hose kit, controller board, capacitor kit, brake manifold, soft-start kit, contactor kit, or full operator rebuild kit. Replacing the motor can correct a failed motor, but it will not repair a seized pump, damaged motor coupler, bad capacitor, incorrect voltage, worn pump pack, leaking hydraulic hose, contaminated fluid, or a gate that is dragging or binding.
Compatible With
The HySecurity MX001725 is intended for select HySecurity / Nice HySecurity hydraulic operator applications that require a 5HP, 60Hz, single-phase, 3450 RPM electric motor. Compatibility depends on the exact operator model, serial number, motor nameplate, voltage, phase, RPM, shaft/coupler arrangement, pump pack layout, and current HySecurity parts documentation.
- Select HySecurity hydraulic gate operator applications where MX001725 is listed in the parts diagram
- Select high-output hydraulic pump pack applications requiring a 5HP single-phase electric motor
- Select 60Hz, 1-phase, 208-230VAC / 230VAC motor replacement applications where HySecurity specifies MX001725
- Operator repairs where the original electric motor is marked, listed, or cross-referenced as MX001725
Do not assume MX001725 fits every HySecurity hydraulic operator. HySecurity operators may use different motor voltages, horsepower ratings, frame styles, RPM ratings, motor brands, start switches, capacitors, couplers, pump assemblies, and mounting layouts. Always confirm by parts diagram and motor tag before ordering.
Related Motor Notes
MX001725 is a 5HP single-phase AC motor and should not be confused with smaller AC motors, DC motors, or three-phase motors used in other HySecurity systems.
- MX001725: 5HP, 60Hz, single-phase, 3450 RPM, 208-230VAC / 230VAC motor reference.
- MX001912: Related 2HP, 60Hz, single-phase motor kit, not the same part.
- MX001647: Related 24VDC, 2HP electric motor, not the same part.
- MX001648: Related 24VDC, 4HP electric motor, not the same part.
If the operator has had a previous motor replacement, pump pack repair, or motor-to-pump coupler change, compare the installed motor nameplate and coupling setup instead of relying only on the operator model.
Not Intended For
- Universal 5HP motor replacement
- 24VDC motor applications such as MX001647 or MX001648
- Three-phase motor applications
- 50Hz applications unless HySecurity specifically confirms compatibility
- Motors requiring a different voltage, horsepower, RPM, shaft, frame, mounting, or start circuit
- Replacing the hydraulic pump, pump pack, hydraulic motor, valve manifold, hose kit, or reservoir unless those parts are ordered separately
- Replacing the motor coupler unless the coupler is specifically included or ordered separately
- Repairing no-run conditions caused by capacitors, start switch, contactor, relay, wiring, controller output, breaker, disconnect, or incoming voltage problems without diagnosis
- Repairing low hydraulic pressure caused by pump wear, leaking hoses, relief valve issues, contaminated fluid, or gate drag without diagnosis
Important Compatibility Warning
MX001725 should be selected by the HySecurity parts diagram and motor nameplate, not by horsepower alone. A 5HP single-phase motor from another source may not match the pump shaft, coupler, mounting, RPM, capacitor/start circuit, voltage, or duty requirements of the HySecurity operator.
If the motor failed, check the cause before installing the replacement. A seized pump, damaged coupler, failed capacitor, incorrect voltage, poor wiring connection, water intrusion, overloaded gate, or dragging gate can damage a replacement motor quickly.
Features & Specifications
| Feature / Specification | Details |
| Manufacturer | HySecurity / Nice HySecurity |
| Part Number | MX001725 |
| Product Type | Replacement electric motor |
| Common Description | Motor, Electric, 60Hz, 5 hp, 1PH, 3450 RPM, 230VAC |
| Horsepower | 5 HP |
| Frequency | 60Hz |
| Phase | Single-phase / 1 phase |
| Voltage Reference | 230VAC; some current listings reference 208-230VAC |
| RPM Reference | 3450 RPM commonly listed |
| System Type | AC electric motor for select hydraulic gate operator pump systems |
| Common Application | Select HySecurity hydraulic operator applications where the parts diagram confirms MX001725 |
| Function | Drives the hydraulic pump in compatible HySecurity hydraulic operator systems |
| Diagnosis Note | Motor failure should be diagnosed with capacitors, start circuit, voltage, wiring, pump load, and motor coupler condition included in the inspection |
| Included Items | Electric motor only unless the current supplier package specifically includes coupler hardware, capacitors, start switch, mounting hardware, threadlocker, anti-seize, labels, or instructions |
| Not Included Unless Listed | Hydraulic pump, pump pack, motor coupler, capacitors, start switch, hydraulic fluid, hoses, fittings, valves, controller board, contactor, relay, and mounting hardware unless separately listed |
Also Known As / Related Part Numbers
- MX001725
- HySecurity MX001725
- Nice HySecurity MX001725
- HySecurity Motor, Electric, 60Hz, 5 hp, 1PH, 3450 RPM, 230VAC
- HySecurity MOTOR, 60HZ, 5HP, 1PH
- HySecurity 5HP single-phase electric motor
- HySecurity 5HP 60Hz motor
- HySecurity 230VAC 5HP motor
- HySecurity 208-230VAC 5HP motor
- HySecurity 3450 RPM electric motor
- HySecurity hydraulic pump electric motor
- HySecurity heavy-duty hydraulic operator motor
- HYS-MX001725, related distributor SKU format
- MX001912, related 2HP 60Hz single-phase motor kit, not the same part
- MX001647, related 24VDC 2HP electric motor, not the same part
- MX001648, related 24VDC 4HP electric motor, not the same part
Related Parts and Accessories
- HySecurity motor-to-pump coupler where the coupling is worn, stripped, loose, or damaged
- Start switch and capacitor components matched to the exact installed motor where motor-start diagnosis requires them
- Hydraulic pump or pump pack assembly where the pump is seized, worn, or not building pressure
- Hydraulic pressure gauge kit where pump output needs to be tested during diagnosis
- Hydraulic fluid specified by the current HySecurity operator manual
- Hydraulic hoses, fittings, quick disconnects, valves, and reservoir parts where leakage or contamination is present
- Contactors, relays, fuses, disconnects, breakers, and wiring where motor power supply issues are present
- Controller board or motor output components where the motor is not receiving proper command voltage
Technician Note
A 5HP single-phase motor places a heavy load on the operator power circuit and hydraulic pump system. Before replacing the motor, check incoming voltage under load, breaker and disconnect condition, contactor/relay operation, capacitor circuit, start switch, wiring terminals, and motor windings.
If the motor runs but the operator does not build hydraulic pressure or move the gate, inspect the motor-to-pump coupler, hydraulic pump, fluid level, relief valve, hoses, quick disconnects, and pump pack. A seized pump, stripped coupler, or dragging gate can damage a new motor quickly.
Before Ordering, Confirm
- Confirm the needed HySecurity part number is MX001725.
- Confirm the original part is listed as Motor, Electric, 60Hz, 5 hp, 1PH, 3450 RPM, 230VAC.
- Confirm the operator model and serial number.
- Confirm the operator uses a 5HP, 60Hz, single-phase motor.
- Confirm the motor voltage is 230VAC or 208-230VAC as required by the operator and motor nameplate.
- Confirm the motor RPM, shaft, mounting, frame, coupling, and pump interface match the original motor.
- Confirm the operator does not require a DC motor, three-phase motor, different horsepower motor, or different voltage motor.
- Confirm the motor coupler and hydraulic pump are not seized, stripped, or damaged.
- Confirm the start switch, start capacitor, run capacitor, contactor, relay, incoming power, and wiring are not the actual cause of the motor issue.
- Confirm whether threadlocker, anti-seize, coupling hardware, mounting hardware, capacitors, start switch, instructions, or other service items are included with the current package.
Installation and Service Notes
Disconnect operator power and secure the gate before servicing the motor or pump pack. This motor may be connected to 230VAC single-phase power, and the start circuit may contain capacitors. Label wiring before removal and compare the replacement motor to the original motor nameplate before installation.
Inspect the motor-to-pump coupler, pump shaft, motor shaft, and mounting alignment before installing the replacement motor. After installation, verify proper motor rotation, normal hydraulic pressure response, smooth gate movement, no unusual noise, and no overheating. If the motor hums, labors, overheats, or trips protection, stop and diagnose the pump, capacitors, wiring, voltage, and gate load.
Professional Advisory
Replacing a 5HP single-phase motor in a hydraulic gate operator can involve high-current line voltage, capacitor circuits, moving gate parts, hydraulic pressure, rotating shafts, and sensitive controller electronics. A qualified HySecurity gate technician or electrician should handle the repair when the operator has repeated motor failures, start-circuit issues, hydraulic pressure problems, or unknown prior repairs.
Do not bypass fuses, contactors, relays, start switches, capacitors, controller protections, monitored entrapment protection, photo eyes, safety edges, limits, or disconnects to make the motor run. The motor and hydraulic system should be repaired correctly and fully tested before the gate is returned to service.
Product Questions & Answers
What is the HySecurity MX001725 used for?
The HySecurity MX001725 is a 5HP, 60Hz, single-phase electric motor used in select HySecurity hydraulic gate operator systems where the parts diagram lists this motor.
What voltage is MX001725?
MX001725 is commonly listed as a 230VAC motor, with some current listings referencing 208-230VAC. Always verify the motor nameplate and operator wiring before ordering.
What RPM is MX001725?
Current listings commonly describe MX001725 as a 3450 RPM electric motor.
Is MX001725 a single-phase motor?
Yes. MX001725 is commonly listed as a 1PH / single-phase motor.
Is MX001725 the same as MX001912?
No. MX001725 is a 5HP single-phase motor. MX001912 is a related 2HP, 60Hz, single-phase motor kit. They should not be substituted without HySecurity parts-diagram confirmation.
Will MX001725 fix a hydraulic operator that will not move?