NICE Apollo 1050I Control Board for Single or Dual Gate Applications
The 1050I is part of the NICE Apollo 1050 controller family used to manage compatible gate operator systems. The control board is the decision center for the gate, handling motor output, limit inputs, accessory commands, radio/receiver functions where applicable, master/slave dual gate operation, timers, and safety inputs. It is often considered when an older Apollo control platform is being replaced or when a 1050-equipped operator has a failed board. Because 1050 boards exist in multiple suffixes and safety configurations, the I, US, and USR versions should not be treated as automatically interchangeable. The installed operator, region/code requirements, monitored safety needs, receiver setup, and accessory wiring should be reviewed before replacing the board.
This is a fitment-sensitive gate operator service part. Match the part number, operator family, control box style, hardware style, and installed system layout before ordering. Similar NICE Apollo parts may look close in photos but can differ by mounting hole pattern, actuator generation, board revision, safety monitoring requirement, or included hardware.
Compatible With
- Compatible NICE Apollo operators designed for the 1050 control platform
- Single gate applications using the correct 1050 board configuration
- Dual gate master/slave applications using compatible Apollo 1050 controls
- Select 12 VDC and 24 VDC Apollo DC operator systems when confirmed by board and operator documentation
- Retrofit applications from older Apollo control platforms only when the full system requirements are met
Features & Specifications
| Manufacturer | NICE Apollo |
|---|
| Product Type | Gate operator control board |
|---|
| Part Number | 1050I |
|---|
| Application | Single or dual compatible Apollo gate operator control |
|---|
| Compatible Operator Type | Select Apollo DC swing and slide gate operators using the 1050 platform |
|---|
| Voltage | Verify operator and board documentation; commonly associated with 12/24 VDC Apollo systems |
|---|
| Safety Monitoring | Depends on board version and installation requirements |
|---|
| Notes | Exact suffix matters; do not substitute 1050I, 1050US, and 1050USR without verification |
|---|
Also Known As / Related Part Numbers
- 1050I
- 1050i
- NICE-1050I
- Apollo 1050 control board
- 1050 controller
- 1050US related U.S. board
- 1050USR related receiver board
- 1050U related listing reference
Technician Note
- Control-board replacement should include a wiring and accessory review, not just a board swap.
- The 1050I suffix may not meet the same U.S. UL325 monitored safety requirements as U.S. board variants.
- If replacing an older board, confirm whether a retrofit bracket kit such as 10055090 is needed.
Before Ordering Checklist
- Match the exact board suffix on the existing controller.
- Confirm operator voltage, motor type, and single/dual configuration.
- Check monitored safety-device requirements for the installation.
- Label wiring before removing the old board.
- After replacement, program limits, accessories, transmitters, timers, and safety settings according to the correct manual.
Professional Advisory
Gate operators can involve stored force, moving gate hardware, low-voltage accessories, battery systems, and line-voltage power inside the control box. Do not bypass monitored safety devices or operate a gate with unsafe movement. For control-board replacement, electrical troubleshooting, welding, or unknown wiring conditions, use a qualified gate technician.
Product Questions & Answers
Is 1050I the same as 1050US?
No. They are related 1050 family boards, but suffixes can reflect different safety, market, or receiver configurations. Match the required board version before ordering.
Can this board run a dual gate system?
The 1050 control platform is commonly associated with single and dual gate applications when the correct board and wiring configuration are used.
Does replacing the board fix all gate problems?
Not always. Motor, battery, transformer, limit, accessory wiring, and safety-device faults can mimic a bad board.
Do I need monitored safety devices?
Many U.S. installations using current UL325-compliant controls require monitored entrapment protection. Do not bypass required safety devices.
Can I install this board in an older Apollo control box?
Some retrofits require mounting brackets and wiring review. The 10055090 bracket kit is commonly associated with mounting 1050 boards in older Apollo control boxes.