HySecurity MX001667, MOTOR KIT,60HZ,575,3PH,1HP,3450
The HySecurity MX001667 is a replacement 1HP, 60Hz, three-phase electric motor kit for select HySecurity and Nice HySecurity hydraulic gate operator systems. It is commonly listed as MOTOR KIT, 60HZ, 575, 3PH, 1HP, 3450 and as Motor, Electric, 60Hz, 1 hp, 3 phase, 3450 RPM, 575VAC.
This motor is part of the electric-to-hydraulic drive system used in compatible HySecurity operators. In a hydraulic gate operator, the electric motor drives the hydraulic pump so the pump pack can build pressure and move hydraulic fluid through the valves, hoses, manifolds, and hydraulic drive components. When the motor is weak, overheated, electrically failed, wired incorrectly, or not receiving proper three-phase power, the operator may fail to build pressure or may struggle to move the gate under load.
HySecurity SlideDriver documentation lists MX001667 as the 575VAC three-phase 1HP motor for select SlideDriver 10 and 40 SS / E configurations. Current listings also identify MX001667 as a Baldor electric motor and reference SlideDriver 15 / 40 and SwingRiser 14 applications where confirmed. Because motor fitment depends on the installed operator, pump pack, voltage configuration, and control system, this motor should be matched by the HySecurity parts diagram and the motor nameplate before ordering.
What This Motor Kit Does
The MX001667 electric motor provides the rotation needed to drive the hydraulic pump in compatible HySecurity hydraulic operators. The hydraulic pump then supplies the pressure and flow needed for the operator to move the gate or hydraulic drive system, depending on the operator family.
This is the electric motor kit only unless the current package specifically includes additional parts. It is not a complete pump pack, hydraulic motor, hose kit, controller board, brake manifold, soft-start kit, contactor kit, overload kit, transformer, or full operator rebuild kit. Replacing the motor can correct a failed motor, but it will not repair a seized pump, damaged motor coupler, incorrect incoming voltage, bad contactor, failed overload, damaged wiring, worn pump pack, leaking hydraulic hose, contaminated fluid, or a gate that is dragging or binding.
Compatible With
The HySecurity MX001667 is intended for select HySecurity / Nice HySecurity hydraulic operator applications that require a 1HP, 60Hz, three-phase, 575VAC, 3450 RPM electric motor. Compatibility depends on the exact operator model, serial number, motor brand, motor nameplate, voltage, phase, RPM, shaft/coupler arrangement, pump pack layout, contactor/overload setup, and current HySecurity parts documentation.
- Select HySecurity SlideDriver 10 SS / E configurations where the parts diagram lists MX001667
- Select HySecurity SlideDriver 40 SS / E configurations where the parts diagram lists MX001667
- Select HySecurity SlideDriver 15 / 40 applications where current listings and the operator parts diagram confirm MX001667
- Select HySecurity SwingRiser 14 applications where the parts diagram confirms MX001667
- Select 1HP, 60Hz, three-phase, 575VAC motor replacement applications where HySecurity specifies MX001667
- Hydraulic pump pack repairs where the original electric motor is marked, listed, or cross-referenced as MX001667
Do not assume MX001667 fits every HySecurity hydraulic operator. HySecurity operators may use different motor voltages, horsepower ratings, frame styles, RPM ratings, motor brands, contactors, overloads, couplers, pump assemblies, and mounting layouts. Always confirm by parts diagram and motor tag before ordering.
MX001667 and Related Motor Notes
MX001667 is commonly listed as a 1HP, 60Hz, three-phase, 575VAC electric motor. It should not be confused with lower-voltage three-phase motors, single-phase motors, DC motors, or other AC motor references.
- MX001667: 1HP, 60Hz, three-phase, 3450 RPM, 575VAC electric motor kit.
- MX001636: Related 1HP, 60Hz, three-phase, 208/230/460VAC motor reference, not the same part.
- MX001635: Related 1HP, 60Hz, single-phase, 115/208/230VAC motor reference, not the same part.
- MX001911: Related 1HP, 60Hz, single-phase motor kit, not the same part.
- MX001912: Related 2HP, 60Hz, single-phase motor kit, not the same part.
- MX001638: Related 2HP, 60Hz, three-phase motor reference, not the same part.
- MX001647: Related 24VDC, 2HP electric motor, not the same part.
- MX001648: Related 24VDC, 4HP electric motor, not the same part.
If the operator has had a previous motor replacement, pump pack repair, voltage conversion, or motor-to-pump coupler change, compare the installed motor nameplate and coupling setup instead of relying only on the operator model.
Not Intended For
- Universal 1HP motor replacement
- 208/230/460VAC three-phase motor applications that require MX001636 or another lower-voltage three-phase motor
- Single-phase motor applications such as MX001635, MX001911, or MX001912
- 24VDC motor applications such as MX001647 or MX001648
- 50Hz applications unless HySecurity specifically confirms compatibility
- Motors requiring a different voltage, horsepower, RPM, shaft, frame, mounting, or control arrangement
- Replacing the hydraulic pump, pump pack, hydraulic motor, valve manifold, hose kit, or reservoir unless those parts are ordered separately
- Replacing the motor coupler unless the coupler is specifically included or ordered separately
- Repairing no-run conditions caused by contactors, overloads, wiring, controller output, breaker, disconnect, or incoming voltage problems without diagnosis
- Repairing low hydraulic pressure caused by pump wear, leaking hoses, relief valve issues, contaminated fluid, or gate drag without diagnosis
Important Compatibility Warning
MX001667 should be selected by the HySecurity parts diagram and motor nameplate, not by horsepower alone. A 1HP three-phase motor from another source may not match the pump shaft, coupler, mounting, RPM, voltage, service factor, enclosure style, control system, or duty requirements of the HySecurity operator.
The 575VAC rating is critical. Do not substitute this motor into a 208/230/460VAC operator or replace a 575VAC motor with a lower-voltage motor unless the entire electrical configuration is reviewed and confirmed by HySecurity documentation and a qualified technician.
Features & Specifications
| Feature / Specification | Details |
| Manufacturer | HySecurity / Nice HySecurity |
| Part Number | MX001667 |
| Product Type | Replacement electric motor kit |
| Common Description | MOTOR KIT, 60HZ, 575, 3PH, 1HP, 3450 |
| Alternate Description | Motor, Electric, 60Hz, 1 hp, 3 phase, 3450 RPM, 575VAC |
| Horsepower | 1 HP |
| Frequency | 60Hz |
| Phase | Three-phase / 3PH |
| Voltage Reference | 575VAC commonly listed; some listings also reference 600VAC 60Hz 3-phase supply class |
| RPM Reference | 3450 RPM commonly listed |
| Motor Brand Reference | Current listings commonly describe this as a Baldor electric motor; verify motor tag before ordering |
| Documented SlideDriver Reference | Select SlideDriver 10 and 40 SS / E configurations where HySecurity documentation lists MX001667 |
| Additional Listing References | SlideDriver 15 / 40 and SwingRiser 14 where current listings and parts diagrams confirm fitment |
| Function | Drives the hydraulic pump in compatible HySecurity hydraulic operator systems |
| Common Included Items | Some listings reference two single-use Loctite packets; verify current package contents before publishing as guaranteed |
| Not Included Unless Listed | Hydraulic pump, pump pack, motor coupler, hydraulic fluid, hoses, fittings, valves, controller board, contactor, overload, disconnect, and mounting hardware unless separately listed |
Also Known As / Related Part Numbers
- MX001667
- HySecurity MX001667
- Nice HySecurity MX001667
- HySecurity MOTOR KIT, 60HZ, 575, 3PH, 1HP, 3450
- HySecurity Motor, Electric, 60Hz, 1 hp, 3 phase, 3450 RPM, 575VAC
- HySecurity 1HP three-phase electric motor
- HySecurity 1HP 60Hz 3-phase motor
- HySecurity 575VAC 1HP motor
- HySecurity 600VAC 1HP motor reference, where listed by supplier supply class
- HySecurity 3450 RPM electric motor
- HySecurity Baldor 1HP electric motor
- HySecurity hydraulic pump electric motor
- HySecurity SlideDriver 575VAC motor
- HySecurity SwingRiser 14 motor, where confirmed by parts diagram
- HYS-MX001667, related distributor SKU format
- MX001636, related 1HP 60Hz three-phase 208/230/460VAC motor, not the same part
- MX001635, related 1HP 60Hz single-phase motor, not the same part
- MX001911, related 1HP 60Hz single-phase motor kit, not the same part
- MX001912, related 2HP 60Hz single-phase motor kit, not the same part
- MX001638, related 2HP 60Hz three-phase motor, not the same part
- MX001647, related 24VDC 2HP electric motor, not the same part
- MX001648, related 24VDC 4HP electric motor, not the same part
Related Parts and Accessories
- HySecurity motor-to-pump coupler where the coupling is worn, stripped, loose, or damaged
- Hydraulic pump or pump pack assembly where the pump is seized, worn, or not building pressure
- Hydraulic pressure gauge kit where pump output needs to be tested during diagnosis
- Hydraulic fluid specified by the current HySecurity operator manual
- Hydraulic hoses, fittings, quick disconnects, valves, and reservoir parts where leakage or contamination is present
- Contactors, overloads, fuses, disconnects, breakers, and wiring where motor power supply issues are present
- Controller board or motor output components where the motor is not receiving proper command voltage
Technician Note
A 575VAC three-phase motor should be diagnosed with the full power circuit included. Check all three phases, phase balance, incoming voltage under load, disconnect condition, breaker/fuse condition, contactor operation, overload setting, wiring terminals, and motor windings before replacing the motor.
If the motor runs but the operator does not build hydraulic pressure or move the gate, inspect the motor-to-pump coupler, hydraulic pump, fluid level, relief valve, hoses, quick disconnects, and pump pack. A seized pump, stripped coupler, or dragging gate can damage a new motor quickly.
Before Ordering, Confirm
- Confirm the needed HySecurity part number is MX001667.
- Confirm the original part is listed as MOTOR KIT, 60HZ, 575, 3PH, 1HP, 3450.
- Confirm the operator model and serial number.
- Confirm the operator uses a 1HP, 60Hz, three-phase motor.
- Confirm the motor voltage is 575VAC as required by the operator and motor nameplate.
- Confirm the motor RPM, shaft, mounting, frame, coupling, and pump interface match the original motor.
- Confirm the operator does not require a 208/230/460VAC motor, single-phase motor, DC motor, different horsepower motor, or different voltage motor.
- Confirm the motor coupler and hydraulic pump are not seized, stripped, or damaged.
- Confirm the contactor, overload, incoming power, phase balance, controller output, and wiring are not the actual cause of the motor issue.
- Confirm whether threadlocker, anti-seize, coupling hardware, mounting hardware, instructions, or other service items are included with the current package.
Installation and Service Notes
Disconnect operator power and secure the gate before servicing the motor or pump pack. This motor may be connected to 575VAC three-phase power. Label wiring before removal and compare the replacement motor to the original motor nameplate before installation.
Inspect the motor-to-pump coupler, pump shaft, motor shaft, and mounting alignment before installing the replacement motor. After installation, verify correct motor rotation, normal hydraulic pressure response, smooth gate movement, no unusual noise, and no overheating. If the motor runs backward, hums, labors, overheats, or trips an overload, stop and diagnose the phase wiring, pump load, voltage, and gate condition.
Professional Advisory
Replacing a 575VAC three-phase motor in a hydraulic gate operator can involve high-voltage three-phase power, moving gate parts, hydraulic pressure, rotating shafts, and sensitive controller electronics. A qualified HySecurity gate technician or electrician should handle the repair when the operator has repeated motor failures, phase-loss issues, overload trips, hydraulic pressure problems, or unknown prior repairs.
Do not bypass fuses, contactors, overloads, controller protections, monitored entrapment protection, photo eyes, safety edges, limits, or disconnects to make the motor run. The motor and hydraulic system should be repaired correctly and fully tested before the gate is returned to service.
Product Questions & Answers
What is the HySecurity MX001667 used for?
The HySecurity MX001667 is a 1HP, 60Hz, three-phase, 575VAC electric motor kit used in select HySecurity hydraulic gate operator systems where the parts diagram lists this motor.
What voltage is MX001667?
MX001667 is commonly listed as a 575VAC motor. Some listings also reference the 600VAC three-phase supply class. Always verify the motor nameplate and operator wiring before ordering.
What RPM is MX001667?
Current listings commonly describe MX001667 as a 3450 RPM electric motor.
Is MX001667 a three-phase motor?
Yes. MX001667 is commonly listed as a 3PH / three-phase motor.
Is MX001667 the same as MX001636?
No. MX001667 is the 575VAC three-phase motor reference. MX001636 is a related 1HP three-phase motor reference for 208/230/460VAC applications. They should not be substituted without HySecurity parts-diagram and electrical-system confirmation.
Will MX001667 fix a hydraulic operator that will not move?
It may help if the electric motor has failed, but no-move conditions can also be caused by phase loss, contactor or overload failure, incorrect voltage, damaged wiring, a seized pump, failed coupler, low hydraulic fluid, valve issues, worn drive components, or a dragging gate.