HySecurity MX001911, MOTOR,60HZ,1HP,1PH KIT
The HySecurity MX001911 is a replacement 1HP, 60Hz, single-phase electric motor kit for select HySecurity and Nice HySecurity hydraulic gate operator systems. It is commonly listed as MOTOR, 60HZ, 1HP, 1PH KIT and as a 115/208/230VAC, 3450 RPM electric motor.
This motor is part of the electric-to-hydraulic drive system used in compatible HySecurity operators. In a hydraulic gate operator, the electric motor drives the hydraulic pump so the pump pack can build pressure and move hydraulic fluid through the valves, hoses, manifolds, and hydraulic drive components. When the motor is weak, overheated, electrically failed, or not receiving proper voltage, the operator may fail to build pressure or may struggle to move the gate under load.
Current listings commonly identify MX001911 as a Leeson 1HP electric motor. Because motor fitment depends on the installed operator, pump pack, voltage configuration, and control system, MX001911 should be matched by the HySecurity parts diagram and the motor nameplate before ordering.
What This Motor Kit Does
The MX001911 electric motor provides the rotation needed to drive the hydraulic pump in compatible HySecurity hydraulic operators. The hydraulic pump then supplies the pressure and flow needed for the operator to move the gate or hydraulic drive system, depending on the operator family.
This is the electric motor kit only unless the current package specifically includes additional parts. It is not a complete pump pack, hydraulic motor, hose kit, controller board, capacitor kit, brake manifold, soft-start kit, contactor kit, or full operator rebuild kit. Replacing the motor can correct a failed motor, but it will not repair a seized pump, damaged motor coupler, bad capacitor, incorrect voltage, worn pump pack, leaking hydraulic hose, contaminated fluid, or a gate that is dragging or binding.
Compatible With
The HySecurity MX001911 is intended for select HySecurity / Nice HySecurity hydraulic operator applications that require a 1HP, 60Hz, single-phase, 115/208/230VAC electric motor. Compatibility depends on the exact operator model, serial number, motor brand, motor nameplate, voltage, phase, RPM, shaft/coupler arrangement, pump pack layout, and current HySecurity parts documentation.
- Select HySecurity hydraulic gate operator systems where MX001911 is listed in the parts diagram
- Select 1HP, 60Hz, single-phase, 115/208/230VAC motor replacement applications where HySecurity specifies MX001911
- Select hydraulic pump pack repairs where the original electric motor is marked, listed, or cross-referenced as MX001911
- Select HySecurity gate systems requiring a 3450 RPM Leeson 1HP motor where confirmed by the motor tag and parts diagram
Do not assume MX001911 fits every HySecurity hydraulic operator. HySecurity operators may use different motor voltages, horsepower ratings, frame styles, RPM ratings, motor brands, start switches, capacitors, couplers, pump assemblies, and mounting layouts. Always confirm by parts diagram and motor tag before ordering.
MX001911 and Related Motor Notes
MX001911 is commonly listed as a 1HP, single-phase, 115/208/230VAC electric motor. It should not be confused with 2HP motors, DC motors, three-phase motors, or other AC motor references unless the parts diagram confirms the substitution.
- MX001911: 1HP, 60Hz, single-phase, 115/208/230VAC, 3450 RPM electric motor kit.
- MX001912: Related 2HP, 60Hz, single-phase, 208/230VAC electric motor kit, not the same part.
- MX001725: Related 5HP, 60Hz, single-phase motor reference, not the same part.
- MX001639: Related 5HP, 60Hz, three-phase motor reference, not the same part.
- MX001647: Related 24VDC, 2HP electric motor, not the same part.
- MX001648: Related 24VDC, 4HP electric motor, not the same part.
If the operator has had a previous motor replacement, pump pack repair, or motor-to-pump coupler change, compare the installed motor nameplate and coupling setup instead of relying only on the operator model.
Not Intended For
- Universal 1HP motor replacement
- 2HP single-phase applications that require MX001912
- 5HP single-phase applications that require MX001725
- Three-phase motor applications
- 24VDC motor applications such as MX001647 or MX001648
- 50Hz applications unless HySecurity specifically confirms compatibility
- Motors requiring a different voltage, horsepower, RPM, shaft, frame, mounting, or start circuit
- Replacing the hydraulic pump, pump pack, hydraulic motor, valve manifold, hose kit, or reservoir unless those parts are ordered separately
- Replacing the motor coupler unless the coupler is specifically included or ordered separately
- Repairing no-run conditions caused by capacitors, start switch, contactor, relay, wiring, controller output, breaker, disconnect, or incoming voltage problems without diagnosis
- Repairing low hydraulic pressure caused by pump wear, leaking hoses, relief valve issues, contaminated fluid, or gate drag without diagnosis
Important Compatibility Warning
MX001911 should be selected by the HySecurity parts diagram and motor nameplate, not by horsepower alone. A 1HP single-phase motor from another source may not match the pump shaft, coupler, mounting, RPM, start circuit, voltage, or duty requirements of the HySecurity operator.
If the motor failed, check the cause before installing the replacement. A seized pump, damaged coupler, failed capacitor, incorrect voltage, poor wiring connection, water intrusion, overloaded gate, or dragging gate can damage a replacement motor quickly.
Features & Specifications
| Feature / Specification | Details |
| Manufacturer | HySecurity / Nice HySecurity |
| Part Number | MX001911 |
| Product Type | Replacement electric motor kit |
| Common Description | MOTOR, 60HZ, 1HP, 1PH KIT |
| Motor Type | Electric motor for select hydraulic gate operator pump systems |
| Horsepower | 1 HP |
| Frequency | 60Hz |
| Phase | Single-phase / 1 phase |
| Voltage Reference | 115/208/230VAC commonly listed |
| RPM Reference | 3450 RPM commonly listed |
| Motor Brand Reference | Current listings commonly describe this as a Leeson electric motor; verify motor tag before ordering |
| System Type | AC single-phase motor for select hydraulic gate operator pump systems |
| Function | Drives the hydraulic pump in compatible HySecurity hydraulic operator systems |
| Common Included Items | Some listings reference single-use Loctite threadlocker and Loctite anti-seize packets for motor coupling reassembly; verify current package contents before publishing as guaranteed |
| Not Included Unless Listed | Hydraulic pump, pump pack, motor coupler, capacitors, start switch, hydraulic fluid, hoses, fittings, valves, controller board, contactor, relay, and mounting hardware unless separately listed |
Also Known As / Related Part Numbers
- MX001911
- HySecurity MX001911
- Nice HySecurity MX001911
- HySecurity MOTOR, 60HZ, 1HP, 1PH KIT
- HySecurity Motor, Electric, 60Hz, 1 hp, 1 phase
- HySecurity 1HP single-phase electric motor
- HySecurity 1HP 60Hz motor kit
- HySecurity 115/208/230VAC 1HP motor
- HySecurity 3450 RPM electric motor
- HySecurity Leeson 1HP electric motor
- HySecurity hydraulic pump electric motor
- HySecurity gate operator replacement motor
- HYS-MX001911, related distributor SKU format
- MX001912, related 2HP 60Hz single-phase motor kit, not the same part
- MX001725, related 5HP 60Hz single-phase motor, not the same part
- MX001639, related 5HP 60Hz three-phase motor, not the same part
- MX001647, related 24VDC 2HP electric motor, not the same part
- MX001648, related 24VDC 4HP electric motor, not the same part
Related Parts and Accessories
- HySecurity motor-to-pump coupler where the coupling is worn, stripped, loose, or damaged
- Start switch and capacitor components matched to the exact installed motor where motor-start diagnosis requires them
- Hydraulic pump or pump pack assembly where the pump is seized, worn, or not building pressure
- Hydraulic pressure gauge kit where pump output needs to be tested during diagnosis
- Hydraulic fluid specified by the current HySecurity operator manual
- Hydraulic hoses, fittings, quick disconnects, valves, and reservoir parts where leakage or contamination is present
- Contactors, relays, fuses, disconnects, breakers, and wiring where motor power supply issues are present
- Controller board or motor output components where the motor is not receiving proper command voltage
Technician Note
A single-phase motor that hums, trips, overheats, or will not start should not be replaced until the start circuit and load have been checked. Inspect the start capacitor, run capacitor, start switch, contactor, relay, incoming voltage, wiring terminals, motor windings, and mechanical load before replacing the motor.
If the motor runs but the operator does not build hydraulic pressure or move the gate, inspect the motor-to-pump coupler, hydraulic pump, fluid level, relief valve, hoses, quick disconnects, and pump pack. A seized pump, stripped coupler, or dragging gate can damage a new motor quickly.
Before Ordering, Confirm
- Confirm the needed HySecurity part number is MX001911.
- Confirm the original part is listed as MOTOR, 60HZ, 1HP, 1PH KIT.
- Confirm the operator model and serial number.
- Confirm the operator uses a 1HP, 60Hz, single-phase motor.
- Confirm the motor voltage is 115/208/230VAC as required by the operator and motor nameplate.
- Confirm the motor RPM, shaft, mounting, frame, coupling, and pump interface match the original motor.
- Confirm the operator does not require a 2HP motor, DC motor, three-phase motor, different horsepower motor, or different voltage motor.
- Confirm the motor coupler and hydraulic pump are not seized, stripped, or damaged.
- Confirm the start switch, start capacitor, run capacitor, contactor, relay, incoming power, and wiring are not the actual cause of the motor issue.
- Confirm whether threadlocker, anti-seize, coupling hardware, mounting hardware, instructions, capacitors, start switch, or other service items are included with the current package.
Installation and Service Notes
Disconnect operator power and secure the gate before servicing the motor or pump pack. This motor may be connected to 115VAC, 208VAC, or 230VAC single-phase power, and the start circuit may contain capacitors. Label wiring before removal and compare the replacement motor to the original motor nameplate before installation.
Inspect the motor-to-pump coupler, pump shaft, motor shaft, and mounting alignment before installing the replacement motor. After installation, verify proper motor rotation, normal hydraulic pressure response, smooth gate movement, no unusual noise, and no overheating. If the motor hums, labors, overheats, or trips protection, stop and diagnose the pump, capacitors, wiring, voltage, and gate load.
Professional Advisory
Replacing a 1HP single-phase motor in a hydraulic gate operator can involve line voltage, capacitor circuits, moving gate parts, hydraulic pressure, rotating shafts, and sensitive controller electronics. A qualified HySecurity gate technician or electrician should handle the repair when the operator has repeated motor failures, start-circuit issues, hydraulic pressure problems, or unknown prior repairs.
Do not bypass fuses, contactors, relays, start switches, capacitors, controller protections, monitored entrapment protection, photo eyes, safety edges, limits, or disconnects to make the motor run. The motor and hydraulic system should be repaired correctly and fully tested before the gate is returned to service.
Product Questions & Answers
What is the HySecurity MX001911 used for?
The HySecurity MX001911 is a 1HP, 60Hz, single-phase electric motor kit used in select HySecurity hydraulic gate operator systems where the parts diagram lists this motor.
What voltage is MX001911?
MX001911 is commonly listed as a 115/208/230VAC motor. Always verify the motor nameplate and operator wiring before ordering.
What RPM is MX001911?
Current listings commonly describe MX001911 as a 3450 RPM electric motor.
Is MX001911 a single-phase motor?
Yes. MX001911 is commonly listed as a 1PH / single-phase motor.
Is MX001911 the same as MX001912?
No. MX001911 is a 1HP single-phase motor kit. MX001912 is a related 2HP, 60Hz, single-phase motor kit. They should not be substituted without HySecurity parts-diagram confirmation.
Will MX001911 fix a hydraulic operator that will not move?
It may help if the electric motor has failed, but no-move conditions can also be caused by bad capacitors, a failed start switch, incorrect voltage, damaged wiring, a seized pump, failed coupler, low hydraulic fluid, valve issues, worn drive components, or a dragging gate.