HySecurity MX001641, Motor, Electric, 60Hz, 1 hp, 3PH, 1725 RPM, 208-230/460VAC
HySecurity MX001641 is a 1 hp three-phase AC electric motor rated at 1725 RPM for select HySecurity gate operator applications. Current listings identify this part as a 60Hz, 3 phase motor with a 208-230/460VAC voltage rating.
This motor is used where the HySecurity operator parts diagram calls for MX001641. Because electric motors are voltage-, phase-, RPM-, shaft-, mounting-, and rotation-specific, this part should not be selected by horsepower alone. Confirm the operator model, serial number, original motor label, electrical service, pump or coupler arrangement, and HySecurity parts diagram before ordering.
What This Electric Motor Does
The electric motor provides drive power for the operator system, commonly through the motor-to-pump or motor-to-drive connection depending on the HySecurity operator configuration. In a three-phase AC hydraulic gate operator, the motor must match the correct voltage, phase, horsepower, RPM, shaft arrangement, mounting pattern, and coupling hardware so the hydraulic system can operate at the intended speed and load capacity.
A failed, weak, miswired, or incorrect motor can cause the operator to stall, trip overload protection, run slowly, run in the wrong direction, overheat, fail to start, or make abnormal noise. Similar symptoms can also be caused by incorrect incoming voltage, phase loss, phase imbalance, bad contactors, overload issues, loose wiring, motor coupler damage, hydraulic pump drag, pressure problems, low hydraulic fluid, contaminated fluid, or gate binding.
Compatible With
Use HySecurity MX001641 only where the operator parts diagram, original motor label, or HySecurity documentation confirms this part number.
- Select HySecurity AC gate operator applications where MX001641 is listed as the 1 hp, three-phase, 1725 RPM electric motor.
- Select HySecurity SwingRiser applications where the parts diagram confirms MX001641.
- Repairs where the original motor is marked, listed, or cross-referenced as HySecurity MX001641.
- Applications requiring a 60Hz, 1 hp, 3-phase, 1725 RPM motor with the correct voltage, shaft, coupler, rotation, and mounting arrangement.
- Hydraulic operator repairs where the parts diagram confirms MX001641 as the correct motor for the pump or drive assembly.
Important Compatibility Warning
MX001641 is a three-phase AC motor. It should not be substituted with a single-phase motor, a 24VDC motor, a higher-horsepower motor, a different RPM motor, or a motor with a different shaft or mounting arrangement unless HySecurity documentation specifically confirms the replacement.
Do not confuse MX001641 with MX001640. MX001640 is commonly listed as a 1 hp, single-phase, 1725 RPM motor rated 115/208-230VAC. Even though the horsepower and RPM are similar, the phase and voltage requirements are different, so these motors are not interchangeable in the field without the correct operator electrical configuration and parts diagram approval.
Similar Parts That Are Not Automatically Interchangeable
- mx001640-1-hp-single-phase-1725-rpm-electric-motor.html">HySecurity MX001640 - 1 hp, single-phase, 1725 RPM, 115/208-230VAC motor; not the same as MX001641.
- mx001646-24vdc-3-4-hp-electric-motor.html">HySecurity MX001646 - 24VDC, 3/4 hp electric motor; not the same voltage, phase, or horsepower.
- MX001910-LEESON-34-HP-1PH-ASSY-KIT_p_11444.html">HySecurity MX001910 - 3/4 hp single-phase AC motor, 3450 RPM; not the same horsepower or RPM.
- mx001634-3-4-hp-3-phase-electric-motor-strongarm.html">HySecurity MX001634 - 3/4 hp three-phase AC motor, 3450 RPM; not the same horsepower or RPM.
- mx001637-p-2hp-single-phase-motor-assembly-3450rpm.html">HySecurity MX001637 - 2 hp single-phase motor used in some HydraSupply XL references; not the same horsepower or application.
- mx001638-p-2hp-3-phase-motor-assembly.html">HySecurity MX001638 - 2 hp three-phase motor used in some HydraSupply XL references; not the same horsepower or application.
- Motor couplers, contactors, overloads, pump parts, valve coils, and hydraulic assemblies - related service items, but not the motor itself.
Not Intended For
- Single-phase motor replacement where MX001640 or another single-phase motor is specified.
- 24VDC motor replacement.
- 3450 RPM motor applications unless the parts diagram specifically calls for MX001641.
- Hydraulic pump pack replacement.
- Motor coupler replacement.
- Hydraulic valve, hose, fitting, manifold, or cylinder replacement.
- Limit switch, reset switch, sensor, controller, contactor, overload, or circuit board replacement.
- Repairs where the actual problem is incorrect voltage, phase loss, phase imbalance, pump drag, gate binding, or hydraulic overload.
Features & Specifications
| Feature / Specification | Details |
| Manufacturer | HySecurity / Nice HySecurity |
| Part Number | MX001641 |
| Product Type | Three-phase AC electric motor |
| Horsepower | 1 hp |
| Phase | Three-phase / 3PH / 3 |
| Frequency | 60Hz |
| RPM | 1725 RPM |
| Voltage | 208-230/460VAC |
| Common Description | Motor, electric, 60Hz, 1 hp, 3-phase, 1725 RPM |
| Common Application | Select HySecurity AC gate operator applications where listed by parts diagram |
| Package Contents | Verify current package contents before ordering; coupler, contactor, overload, wiring, and mounting hardware may be separate unless stated |
Also Known As / Related Part Numbers
- MX001641
- HySecurity MX001641
- Nice HySecurity MX001641
- HYS-MX001641
- HYS-mx001641
- HySecurity motor, electric, 60Hz, 1 hp, 3PH, 1725 RPM
- HySecurity 1 hp three-phase 1725 RPM electric motor
- HySecurity 208-230/460VAC 1 hp 3-phase motor
- 1 HP 3-phase replacement motor for HySecurity gate operators
- MX001640 - related 1 hp single-phase 1725 RPM motor; not the same part
- HYS-MX001640 - related distributor SKU format for single-phase motor; not the same part
Related Parts and Accessories
The correct related parts depend on the operator model, motor-to-pump arrangement, incoming electrical service, wiring, and the cause of the original motor failure. Inspect the surrounding drive and electrical components before ordering only the motor.
- Motor coupling hardware - verify the correct coupler by operator model and pump shaft arrangement.
- Contactor and overload components - related electrical switching and protection parts, not the motor.
- Motor wiring and terminal hardware - confirm proper three-phase wiring for the selected voltage.
- Hydraulic pump assembly - separate from the motor and should be inspected for drag or binding.
- Hydraulic fluid, hoses, fittings, and valves - inspect if the motor failed under hydraulic load.
- Phase monitoring or electrical protection components - verify if the operator installation uses them.
Technician Note
Before replacing MX001641, verify that the motor is actually failed. A three-phase motor complaint can be caused by incorrect voltage, phase loss, phase imbalance, bad contactor, tripped overload, loose wiring, damaged coupling, pump drag, hydraulic pressure issues, or gate binding. If the motor failed from overload, incorrect voltage, or a mechanical/hydraulic problem, the replacement may fail again unless the root cause is corrected.
Compare the original motor label to the replacement specification before ordering. Pay close attention to voltage, phase, RPM, horsepower, shaft/coupler arrangement, mounting style, rotation, and wiring. A 1 hp 1725 RPM motor that looks physically similar may still be wrong if the phase, voltage, frame, shaft, or mounting differs.
Before Ordering, Confirm
- The required part number is MX001641.
- The original motor is 1 hp, three-phase, 60Hz, and 1725 RPM.
- The operator electrical service matches the required 208-230/460VAC three-phase configuration.
- The operator model and serial number match the parts diagram being used.
- The replacement is not being confused with MX001640, the related single-phase motor.
- The shaft, motor coupling, mounting, rotation, and wiring arrangement match the original installation.
- The motor failure was not caused by phase loss, incorrect voltage, pump drag, hydraulic overload, gate binding, or failed electrical protection.
- The package contents include what is needed for reassembly, or that coupler-related hardware and electrical components are ordered separately if required.
Installation and Service Notes
- Disconnect and lock out power before servicing the motor or operator electrical system.
- Do not work on energized three-phase motor wiring or live operator controls.
- Confirm the correct voltage tap/wiring configuration before applying power to the replacement motor.
- Verify phase rotation and motor direction before returning the operator to normal service.
- Inspect the motor coupling and pump shaft before installing the new motor.
- Do not force an incorrect shaft, coupling, or mounting arrangement.
- After service, verify proper motor rotation, smooth gate movement, correct hydraulic performance, overload protection, and all required safety devices.
Professional Advisory
Motor replacement on a HySecurity gate operator should be performed by a qualified gate technician or qualified electrical professional when the repair involves three-phase AC line voltage, motor rotation, electrical protection, motor coupling alignment, hydraulic pump load, heavy gate movement, or safety-critical operator performance. Do not bypass fuses, overloads, controller protections, limit controls, inherent entrapment sensors, photo eyes, gate edges, or other safety devices to test a motor.
Product Questions & Answers
What is HySecurity MX001641?
HySecurity MX001641 is a 1 hp three-phase AC electric motor rated at 1725 RPM for select HySecurity gate operator applications. It should be used only where the parts diagram or original motor label confirms this part number.
What voltage is the MX001641 motor?
Current listings identify MX001641 as a 208-230/460VAC three-phase motor. Confirm the voltage wiring against the original motor label and operator documentation before installation.
Is MX001641 single-phase or three-phase?
MX001641 is a three-phase motor. It should not be confused with MX001640, which is the related 1 hp single-phase 1725 RPM motor.
Is MX001641 the same as MX001640?
No. MX001641 is a 1 hp three-phase motor, while MX001640 is a 1 hp single-phase motor. The horsepower and RPM may be similar, but the phase and voltage requirements are different.
Can MX001641 be used on SwingRiser operators?
MX001641 is commonly associated with select HySecurity SwingRiser applications, but it should only be used where the SwingRiser parts diagram lists this exact motor part number.
Can I replace this motor with another 1 hp 1725 RPM motor?
Not without confirming all specifications. Voltage, phase, frame, shaft, mounting, coupler setup, rotation, and operator parts diagram must match before using any replacement motor.
What should be checked before replacing MX001641?
Before replacing the motor, check incoming three-phase voltage, phase loss, phase imbalance, wiring, contactor and overload operation, motor coupling, pump load, hydraulic pressure, and gate movement. These issues can mimic a failed motor or damage a new motor.