AES EL00W-RAD, Commercial Wired eLoop with presence mode (radar)
The AES EL00W-RAD is a wired e-Loop vehicle detection device designed for commercial and high-use gate applications where a wired loop-style detector is preferred over a traditional saw-cut induction loop. This model is the presence-mode version with added radar detection, allowing it to detect approaching vehicles and help confirm when a vehicle is stopped over the loop area.
The EL00W-RAD wires directly into the gate board or compatible low-voltage control input. It is not the same type of product as the AES wireless commercial e-Loop kits that require an ETRANS transceiver. For jobs where the installer wants a wired output with COM, N/O, and N/C relay terminals, this model is commonly associated with the AES wired e-Loop range.
What This Wired e-Loop Does
The EL00W-RAD uses magnetometer sensing for vehicle detection and adds radar confirmation for presence-mode operation. In a typical gate application, the detector sends a relay signal to the gate operator or other approved control device when a vehicle is detected. The radar portion is intended to help confirm vehicle presence when a vehicle is stopped above the e-Loop area.
- Detects vehicles using 3-axis magnetometer technology
- Adds radar confirmation for presence-mode applications
- Provides wired relay output to the gate board or compatible control input
- Supports COM, normally open, and normally closed relay connections
- Operates from 12-24 VDC input power
- Designed for surface-mount or flush-mount installation
- Useful for high-use gate entrances, exits, and controlled vehicle lanes where the installation supports this type of detector
Compatible With
The AES EL00W-RAD may be used with select gate operators, barrier gates, access control systems, and vehicle detection applications where the control board accepts a compatible low-voltage relay input from a wired detector. Always verify the control board input, wiring requirements, relay logic, and safety-device requirements before ordering or installing.
- Select commercial gate operator control boards with a proper low-voltage vehicle detector input
- Select barrier gate applications where a wired presence-mode vehicle detector is suitable
- Entry or exit lanes where a wired detector is preferred over a wireless e-Loop transceiver setup
- Applications requiring COM, N/O, or N/C relay output from the detector
- Installations where 12-24 VDC power is available for the detector
- Surface-mount or flush-mount installations where the site conditions match the AES wired e-Loop requirements
- Repairs or replacements where the original part number is EL00W-RAD or the documentation calls for the wired presence-mode radar e-Loop
Important Compatibility Warning
The EL00W-RAD should not be selected by appearance alone. AES uses similar part numbers across wired, wireless, commercial surface, inground, exit-mode, and presence-mode e-Loop products. This model is the wired presence-mode version with radar. It is not automatically interchangeable with AES wireless e-Loop sensors, exit-mode loops, inground loops, post-mount loops, or transceiver kits.
- Confirm that the required part number is EL00W-RAD.
- Confirm whether the application needs presence mode with radar or exit mode only.
- Confirm that the gate board can accept the relay output type being used.
- Confirm the site has suitable 12-24 VDC power available.
- Confirm whether the loop will be surface mounted or flush mounted.
- Do not treat this as a wireless e-Loop sensor that pairs to an ETRANS50, ETRANS100, or ETRANS200.
- Do not use this detector as the only safety device on an automated gate system.
EL00W-RAD Compared With Similar AES e-Loop Parts
| AES Part | General Use | Important Difference |
| EL00W-RAD | Wired e-Loop presence mode with radar | Wires directly to the gate board and includes radar confirmation for presence-mode use |
| EL00W | Wired e-Loop exit mode | Exit-mode wired version without the same presence-mode radar function |
| EL00C-RAD | Commercial wireless surface e-Loop presence mode | Wireless commercial surface loop that works with an AES transceiver; not the same as the wired EL00W-RAD |
| EL00IG-RAD | Inground wireless e-Loop presence mode | Different installation style and product family; not a direct substitute for EL00W-RAD |
| EL00M-RAD | Mini wireless e-Loop presence mode | Smaller wireless model for different applications; not the wired commercial EL00W-RAD |
| ETRANS50 / ETRANS100 / ETRANS200 | AES e-Loop transceivers | Used with wireless AES e-Loop devices; they are not the wired EL00W-RAD detector itself |
Similar Parts That Are Not Automatically Interchangeable
- AES EL00W: Wired exit-mode e-Loop. It is related but not the same as the EL00W-RAD presence-mode radar version.
- AES EL00C-RAD: Commercial wireless surface-mount presence-mode e-Loop. It may look similar in naming, but it is not the wired EL00W-RAD.
- AES EL00IG-RAD: Inground wireless presence-mode e-Loop. It is a different product family and installation style.
- AES EL00M-RAD: Mini presence-mode e-Loop. It is not the same commercial wired detector.
- AES ETRANS50, ETRANS100, and ETRANS200: Transceivers used with select AES wireless products. They do not replace the EL00W-RAD wired detector.
- AES EDR00: Diagnostic remote used for supported e-Loop adjustments. It is an accessory, not the wired detector.
Not Intended For
- Replacing a wireless AES e-Loop sensor without checking the part number and system type
- Applications requiring only exit mode where EL00W is specified instead
- Installations that require an AES wireless transceiver kit instead of a wired relay-output detector
- Gate operators that do not provide a proper compatible input or power source for this detector
- Use as the sole safety device on an automated gate system
- Bypassing photo eyes, safety edges, monitored entrapment protection, emergency access, fire access, or required safety circuits
- Switching high-voltage motor power or loads outside the detector relay rating
Features & Specifications
| Feature / Specification | Details |
| Manufacturer | AES / AES Global |
| Part Number | EL00W-RAD |
| Product Type | Wired e-Loop vehicle detector |
| Operating Mode | Presence mode with added radar detection |
| Detection Technology | 3-axis magnetometer vehicle detection with radar confirmation |
| Input Voltage | 12-24 VDC |
| Relay Outputs | COM, N/O, and N/C |
| Cable | 6-core cable, commonly listed as approximately 10 yards long |
| Cable Diameter | Approximately 4.1 mm |
| Approximate Size | 4.7 inches diameter with outside shell, approximately 0.7 inches high |
| Loop Interior Size | Approximately 2.7 inches inside loop |
| Load Rating | Commonly listed as 10 tonne static load limit |
| Installation Style | Surface mount or flush mount for presence-mode applications |
| Concealed Mounting Note | Concealed mounting is associated with the exit-mode wired version, not the presence-mode radar version |
| Radar Read Distance | Minimum approximately 1.9 ft, default approximately 4.2 ft, maximum approximately 6.5 ft where properly adjusted |
| Magnetometer Detection Zones | High, medium, and low detection areas vary by setup and site conditions |
| Operating Temperature | Commonly listed as -40 degrees F to 176 degrees F |
| Protection Note | Fully potted and water protected; verify current AES documentation if an exact IP68/IP69 rating is required for the job specification |
| Typical Package Content | Wired e-Loop presence-mode unit and concrete fixing hardware, unless the listing or current kit packaging states otherwise |
Also Known As / Related Part Numbers
- AES EL00W-RAD
- EL00W-RAD
- EL00WRAD
- AES Wired e-Loop Presence Mode
- AES Wired e-Loop Presence Mode with Radar
- AES Wired eLoop Presence Mode Radar
- AES Commercial Wired e-Loop Presence Mode
- AES Wired Vehicle Detection System Presence Mode
- AES e-Loop Wired Presence Mode
- EL00W - related wired exit-mode e-Loop, not the same part
- EL00C-RAD - related commercial wireless surface e-Loop presence mode, not the same part
- EL00IG-RAD - related inground wireless e-Loop presence mode, not the same part
- EL00M-RAD - related mini wireless e-Loop presence mode, not the same part
- ETRANS50 - related AES e-Loop transceiver, not included unless specified
- ETRANS100 - related AES e-Loop transceiver, not included unless specified
- ETRANS200 - related AES e-Loop transceiver, not included unless specified
- EDR00 - related AES e-diagnostics remote accessory, not the same part
Related Parts and Accessories
- AES EL00W wired e-Loop exit-mode detector for applications that do not require presence-mode radar
- AES EDR00 e-diagnostics remote for supported e-Loop adjustments and diagnostics
- AES wireless commercial e-Loop products where a transceiver-based system is required instead of a wired detector
- AES ETRANS50, ETRANS100, or ETRANS200 transceivers for select AES wireless e-Loop systems
- Compatible gate operator control boards where the detector relay output is being connected
- Gate safety photo eyes and monitored safety edges where required by the gate operator and safety standard
Technician Note
The most important field check is whether the job needs the wired EL00W-RAD or a wireless AES e-Loop product. The EL00W-RAD wires directly to the gate board, while AES wireless e-Loop products pair with a compatible ETRANS transceiver. Those systems are not the same, even though the product names are similar.
For presence-mode work, also confirm that the gate operator logic is set up correctly. A vehicle detector can send the right relay signal and still not hold or release the gate correctly if the detector input, close timer, loop input type, or safety input wiring is wrong. Radar settings, magnetic field release level, sensitivity, mounting position, and nearby metal can also affect operation.
Before Ordering, Confirm
- Confirm the exact part number is EL00W-RAD.
- Confirm the application needs wired presence mode with radar, not exit mode only.
- Confirm the control board supports the detector relay output being used.
- Confirm whether the input needs COM/N/O or COM/N/C wiring.
- Confirm 12-24 VDC power is available at the installation location.
- Confirm the planned installation is surface mount or flush mount.
- Confirm the cable route and whether any cable protection or cover is needed.
- Confirm the detector will not be used as the only gate safety device.
- Confirm the gate has required monitored safety devices where applicable.
- Confirm whether an e-diagnostics remote is needed for radar or sensitivity adjustments.
- Confirm package contents if concrete fixing hardware, cable cover, sealant, or accessories are required for the job.
Installation and Service Notes
- Follow the current AES installation instructions for mounting, wiring, calibration, and detector setup.
- Use only a compatible low-voltage relay input on the gate operator or access control device.
- Do not use the detector relay to switch gate motor power or high-voltage loads.
- Keep the detector location clear of conditions that may cause false detection or poor release, including unsuitable mounting, excessive nearby metal, damaged cable, or incorrect sensitivity settings.
- After installation, test approach detection, stopped-vehicle presence, gate hold behavior, release timing, and normal gate closing operation.
- Test all required safety photo eyes, safety edges, monitored entrapment devices, and emergency access functions after service.
Professional Advisory
Vehicle detector wiring, gate operator inputs, monitored safety circuits, and automated gate movement should be handled by a qualified gate technician when the wiring is unclear, the gate controls vehicle traffic, or the operator has safety-device requirements. Do not bypass photo eyes, safety edges, monitored entrapment protection, emergency access equipment, fire access equipment, or operator safety functions to make a detector appear to work.
Product Questions & Answers
Is the AES EL00W-RAD a wired or wireless e-Loop?
The AES EL00W-RAD is a wired e-Loop presence-mode detector. It wires directly into the gate board or compatible low-voltage control input. It should not be confused with AES wireless e-Loop sensors that require an ETRANS transceiver.
What is the difference between EL00W-RAD and EL00W?
EL00W-RAD is the wired presence-mode version with added radar detection. EL00W is the wired exit-mode version. They are related AES wired e-Loop products, but they should not be treated as the same part.
Does the EL00W-RAD include radar detection?
Yes. The EL00W-RAD uses magnetometer vehicle detection with added radar confirmation for presence-mode operation. The radar function helps detect vehicles stopped above the e-Loop area when the system is installed and adjusted correctly.
Can the EL00W-RAD be used as the only gate safety device?
No. Presence-mode vehicle detection should not be used as the only safety device on an automated gate system. Required photo eyes, safety edges, monitored entrapment protection, and other safety devices must remain installed and working as required for the gate operator.
What relay outputs does the EL00W-RAD provide?
The EL00W-RAD is listed with COM, normally open, and normally closed relay outputs. Before wiring, confirm which input on the gate operator should be used and whether the application requires N/O or N/C relay logic.
No. The EL00W-RAD is the wired e-Loop detector and is designed to wire directly into the gate board or compatible control input. ETRANS50, ETRANS100, and ETRANS200 are used with select AES wireless e-Loop systems and are not the wired detector itself.
What should be checked before replacing an EL00W-RAD?
Before replacing the detector, check input power, relay wiring, cable condition, mounting location, radar settings, magnetic sensitivity, gate board input programming, close timer settings, and related safety devices. A wiring or setup issue can look like a failed detector.