HySecurity MX001306-P, HAND PUMP, CAST IRON, HG/SR
The HySecurity MX001306-P is a replacement cast iron hand pump for select HySecurity and Nice HySecurity hydraulic gate operator systems. It is commonly listed as HAND PUMP, CAST IRON, HG/SR, with HG commonly associated with HydraSwing and SR commonly associated with SwingRiser.
This hand pump is used as part of the manual hydraulic operation system on compatible operators. In the correct installation, the hand pump works with the hydraulic reservoir, manual valve function, brake manifold, hoses, fittings, pump system, and actuator circuit so the gate can be manually moved according to the proper HySecurity service procedure.
HySecurity HydraSwing documentation references manual hand pump operation on HydraSwing 40, 40F, 80F, and 150 models. SwingRiser systems also use a HydraSupply power and control arrangement, so the hand pump should be matched by operator family, pump cabinet layout, hydraulic diagram, and parts documentation before ordering.
What This Hand Pump Does
The MX001306-P hand pump allows hydraulic pressure to be manually generated in compatible HySecurity systems where the operator design supports hand pump operation. This can be used for manual gate movement during service or power-loss conditions when the proper manual operation procedure is followed.
If the hand pump is worn, leaking, stuck, air-bound, contaminated, installed with incorrect fittings, or used without the correct manual valve / release procedure, the operator may not move manually, may move slowly, may fail to hold, or may leak hydraulic fluid. Similar symptoms can also be caused by low hydraulic fluid, blocked or damaged hoses, brake manifold issues, manual valve problems, cylinder leakage, pump pack issues, or a gate that is binding mechanically.
Compatible With
The HySecurity MX001306-P is intended for select HySecurity / Nice HySecurity hydraulic gate operator applications where this cast iron hand pump is specified. Compatibility depends on the operator model, HydraSupply layout, hydraulic circuit, hand pump mounting, fittings, valve arrangement, and current HySecurity parts documentation.
- Select HySecurity HydraSwing applications where the parts diagram lists MX001306-P
- Select HySecurity HydraSwing 40 applications where the hydraulic manual operation system uses this hand pump
- Select HySecurity HydraSwing 40F applications where the hydraulic manual operation system uses this hand pump
- Select HySecurity HydraSwing 80F applications where the hydraulic manual operation system uses this hand pump
- Select HySecurity HydraSwing 150 applications where the hydraulic manual operation system uses this hand pump
- Select HySecurity SwingRiser applications where the parts diagram lists MX001306-P
- HydraSupply cabinet repairs where the original hand pump is marked, listed, or cross-referenced as MX001306-P
Do not assume MX001306-P fits every HySecurity HydraSwing, SwingRiser, HydraLift, SlideDriver, StrongArm, SlideSmart, SwingSmart, HydraWedge, Smart DC, Smart Touch, or SmartCNX operator. Manual hydraulic pump parts should be verified by parts diagram and hydraulic layout.
MX001306-P vs. Related Hydraulic Parts
MX001306-P is a manual hand pump, not a complete electric pump pack or valve assembly. Keep it separate from other hydraulic parts that may be located nearby in the operator cabinet.
- MX001306-P: Cast iron hand pump for select HydraSwing / SwingRiser applications.
- MX001257: Two-position manual directional valve cartridge, not the same part.
- MX3475: Offset hydraulic reservoir assembly, not the same part.
- MX000686: Breather cap used on select reservoirs, not the same part.
- MX001107: 3000 PSI pressure gauge and fittings kit, not the same part.
- MX001638-P: 2 HP, 3-phase electric motor assembly, not the same part.
- MX002054-P: Motor-to-pump coupling kit, not the same part.
- MX3317-01 / MX3317-02: HydraSwing 80F / 150 brake manifold assemblies, not the same part.
- MX3261-01 / MX3261-02: HydraSwing 40 / 40F brake manifold assemblies, not the same part.
The hand pump may work alongside valves, reservoirs, hoses, fittings, and manifold components, but it should not be used as a substitute for those parts.
Manual Operation Warning
Manual hand pump operation must be performed according to the current HySecurity procedure for the specific operator model. On HydraSwing systems, the brake manifold / manual release function and hand pump procedure matter. Using the hand pump without following the correct release and valve steps can damage hydraulic components.
Do not force the hand pump if the gate does not move. A gate that will not move manually may have a closed valve, locked brake manifold, low fluid, blocked hose, damaged cylinder, seized hinge, mechanical obstruction, or incorrect manual operation setup.
Related Hydraulic Parts and Service Items
Hand pump replacement should be diagnosed with the complete hydraulic system in mind. If manual operation is not working, the hand pump may not be the only possible cause.
- HySecurity MX001257 manual directional valve cartridge where manual hydraulic direction control is being serviced
- HySecurity MX3475 offset reservoir assembly where the reservoir is cracked, leaking, or contaminated
- HySecurity MX000686 breather cap where the reservoir vent cap is missing or blocked
- HySecurity hose kits and fittings where hydraulic fluid is leaking or restricted
- HySecurity brake manifold assemblies where release, stopping, or holding behavior is being diagnosed
- HySecurity hydraulic cylinder assemblies where cylinder leakage or bypassing is suspected
- HySecurity pressure gauge kits where hydraulic pressure needs to be checked
- Hydraulic fluid specified by the current HySecurity operator manual
Not Intended For
- Universal hydraulic hand pump replacement
- Replacing an electric hydraulic pump pack
- Replacing the electric motor, motor-pump coupler, reservoir, manual directional valve, brake manifold, hose kit, hydraulic cylinder, or pressure gauge unless those parts are separately ordered
- Correcting manual operation problems caused by low fluid, closed manual valve, brake manifold issue, hose restriction, cylinder leakage, or gate binding without diagnosis
- Operating a gate manually without following the correct HySecurity hand pump and manual release procedure
- Opening or disconnecting hydraulic fittings from a pressurized circuit
Important Compatibility Warning
MX001306-P should be selected by HySecurity part number, operator model, hydraulic circuit, pump cabinet layout, mounting style, and parts diagram. A hand pump that appears similar may not have the same port configuration, seal style, handle arrangement, mounting layout, or hydraulic rating.
If the original hand pump failed because of contaminated hydraulic fluid, water intrusion, over-pressurization, blocked lines, incorrect manual valve use, or mechanical gate binding, replacing only the pump may not correct the root issue. Inspect the hydraulic system and gate movement before returning the operator to service.
Features & Specifications
| Feature / Specification | Details |
| Manufacturer | HySecurity / Nice HySecurity |
| Part Number | MX001306-P |
| Alternate Part Formatting | MX001306P, sometimes used without the dash in distributor or internal references |
| Product Type | Hydraulic hand pump |
| Common Description | HAND PUMP, CAST IRON, HG/SR |
| Material Reference | Cast iron, as listed in the part description |
| Common Operator References | Select HydraSwing and SwingRiser hydraulic operator applications where the parts diagram confirms MX001306-P |
| System Area | Hydraulic manual operation / HydraSupply cabinet area |
| Function | Manually generates hydraulic pressure in compatible operator systems when used according to the proper manual operation procedure |
| Selection Method | Match by HySecurity part number, operator model, hydraulic cabinet layout, mounting, port configuration, fittings, handle arrangement, and parts diagram |
| Included Items | Hand pump only unless the current supplier package specifically includes handle, fittings, seals, mounting hardware, hydraulic fluid, labels, or instructions |
| Not Included Unless Listed | Electric pump pack, electric motor, motor-pump coupler, reservoir, brake manifold, manual directional valve, hose kit, hydraulic cylinder, pressure gauge, hydraulic fluid, and operator hardware unless separately listed |
Also Known As / Related Part Numbers
- MX001306-P
- MX001306P
- MX001306
- HySecurity MX001306-P
- Nice HySecurity MX001306-P
- HySecurity HAND PUMP, CAST IRON, HG/SR
- HySecurity cast iron hand pump
- HySecurity HydraSwing hand pump
- HySecurity SwingRiser hand pump
- HySecurity hydraulic hand pump
- HySecurity HydraSupply hand pump
- HySecurity manual hydraulic hand pump
- HYS-MX001306-P, related distributor SKU format
- MX001257, related manual directional valve cartridge, not the same part
- MX3475, related offset reservoir assembly, not the same part
- MX000686, related breather cap, not the same part
- MX001107, related pressure gauge and fittings kit, not the same part
- MX001638-P, related electric motor assembly, not the same part
- MX002054-P, related motor-to-pump coupling kit, not the same part
Related Parts and Accessories
- HySecurity MX001257 two-position manual directional valve cartridge where the manual valve function is being serviced
- HySecurity MX3475 offset reservoir assembly where the hydraulic reservoir is leaking or contaminated
- HySecurity MX000686 breather cap where the reservoir cap is missing, blocked, or damaged
- HySecurity MX001107 3000 PSI pressure gauge kit where hydraulic pressure needs to be checked
- HySecurity hydraulic hose kits and quick disconnect fittings where leaks or restrictions are present
- HySecurity brake manifold assemblies where manual release, stopping, or holding behavior is being diagnosed
- HySecurity hydraulic cylinder assemblies where cylinder leakage or bypassing is suspected
- Hydraulic fluid specified by the current HySecurity operator manual
Technician Note
Before replacing MX001306-P, confirm whether the hand pump is actually the failed component. A gate that will not move manually may have a low fluid level, closed manual valve, brake manifold issue, blocked hose, bad fitting, cylinder problem, seized hinge, or mechanical obstruction.
If the hand pump is leaking or weak, inspect the connected fittings, seals, reservoir, hydraulic fluid condition, and manual valve circuit. Contaminated fluid or debris in the hydraulic system can damage a replacement hand pump quickly.
Before Ordering, Confirm
- Confirm the needed HySecurity part number is MX001306-P.
- Confirm the original part is listed as HAND PUMP, CAST IRON, HG/SR.
- Confirm the operator model and serial number.
- Confirm the parts diagram lists MX001306-P for the hand pump location.
- Confirm the hand pump mounting, port configuration, handle arrangement, fittings, and hydraulic cabinet layout match the original.
- Confirm the repair does not require a manual directional valve, brake manifold, reservoir, hose kit, cylinder, or electric pump pack instead.
- Confirm the hydraulic fluid is clean and the gate is not binding mechanically.
- Confirm whether handle, fittings, seals, mounting hardware, hydraulic fluid, labels, or instructions are included or must be ordered separately.
Installation and Service Notes
Hand pump service should be performed with the operator disabled, the gate secured, and the hydraulic system handled according to the current HySecurity service procedure. Do not disconnect hoses or fittings from a pressurized hydraulic circuit.
Keep fittings, pump ports, and hydraulic fluid clean during service. Dirt, water, or metal particles can damage the hand pump, valves, cylinders, seals, fittings, and pump components. After installation, verify proper manual valve position, check for leaks, test manual pumping operation, restore normal valve settings, and test all safety devices before returning the operator to service.
Professional Advisory
Hand pump replacement can affect manual gate operation, hydraulic release behavior, and emergency service movement. A qualified HySecurity gate technician should handle this repair if the operator has repeated hydraulic leaks, contaminated fluid, gate drift, manual release problems, or unclear hydraulic routing.
Do not bypass covers, guards, limits, monitored entrapment protection, photo eyes, safety edges, hydraulic controls, manual release components, disconnects, or controller protections to make the gate run. The hydraulic system, mechanical assembly, and safety devices should be repaired correctly and fully tested before the operator is returned to service.
Product Questions & Answers
What is the HySecurity MX001306-P used for?
The HySecurity MX001306-P is a cast iron hand pump used in select HydraSwing and SwingRiser hydraulic gate operator applications where the parts diagram lists this part.
What is MX001306-P commonly listed as?
MX001306-P is commonly listed as HAND PUMP, CAST IRON, HG/SR.
What does HG/SR mean in the MX001306-P description?
In this part description, HG is commonly associated with HydraSwing and SR is commonly associated with SwingRiser. Final fitment should still be verified by parts diagram.
Is MX001306-P an electric pump pack?
No. MX001306-P is a manual hydraulic hand pump. Electric pump packs, pump motors, couplers, reservoirs, and valve assemblies are separate parts.
Will MX001306-P let the gate move manually during a power outage?
It is used as part of the manual hydraulic operation system on compatible operators, but the correct HySecurity manual release and hand pump procedure must be followed for the specific model.
What should I check before replacing MX001306-P?
Check the hand pump, fittings, reservoir, manual valve, brake manifold, hydraulic fluid level, hose routing, cylinder condition, and gate movement before replacing the pump.
Should I force the hand pump if the gate does not move?
No. Do not force the hand pump. Stop and check the manual valve position, brake manifold release, fluid level, hydraulic restrictions, cylinder condition, and gate movement before continuing.