HySecurity MX001636-P, MOTOR ASSY, 1 HP, 3PH, 3450RPM
HySecurity MX001636-P is a 1 HP three-phase AC motor assembly rated at 3450 RPM for select HySecurity gate operator applications. Related base part MX001636 is commonly listed as a 60Hz, 1 HP, 3-phase, 3450 RPM motor with a 208-230/460VAC voltage rating.
The "-P" suffix may indicate a packaged motor assembly or current service package version. Because electric motors are voltage-, phase-, RPM-, shaft-, mounting-, and rotation-specific, this part should not be selected by horsepower alone. Confirm the operator model, serial number, original motor label, electrical service, pump or coupler arrangement, and HySecurity parts diagram before ordering.
What This Motor Assembly Does
The motor assembly provides drive power for the operator system, commonly through the motor-to-pump or motor-to-drive connection depending on the HySecurity operator configuration. In a three-phase AC hydraulic gate operator, the motor must match the correct voltage, phase, horsepower, RPM, shaft arrangement, mounting pattern, and coupling hardware so the operator can run at the intended speed and load capacity.
A failed, weak, miswired, or incorrect motor can cause the operator to stall, trip overload protection, run slowly, run in the wrong direction, overheat, fail to start, or make abnormal noise. Similar symptoms can also be caused by incorrect incoming voltage, phase loss, phase imbalance, bad contactors, overload issues, loose wiring, motor coupler damage, hydraulic pump drag, pressure problems, low hydraulic fluid, contaminated fluid, or gate binding.
Compatible With
Use HySecurity MX001636-P only where the operator parts diagram, original motor label, or HySecurity documentation confirms this part number or the approved related base part number.
- Select HySecurity AC gate operator applications where MX001636-P is listed as the 1 HP, three-phase, 3450 RPM motor assembly.
- Select HySecurity SlideDriver 15 and SlideDriver 40 SS/E 3-phase applications where the parts diagram confirms MX001636 or MX001636-P.
- Select HySecurity SwingRiser applications where the parts diagram confirms this 1 HP, 3-phase, 3450 RPM motor assembly.
- Select HySecurity WedgeSmart applications where the parts diagram confirms this motor assembly.
- Repairs where the original motor is marked, listed, or cross-referenced as HySecurity MX001636-P or the approved related part number MX001636.
- Applications requiring a 60Hz, 1 HP, 3-phase, 3450 RPM motor with the correct voltage, shaft, coupler, rotation, and mounting arrangement.
Important Compatibility Warning
MX001636-P is a three-phase AC motor assembly. It should not be substituted with a single-phase motor, a 24VDC motor, a 1725 RPM motor, a different horsepower motor, or a motor with a different shaft or mounting arrangement unless HySecurity documentation specifically confirms the replacement.
Do not confuse MX001636-P with MX001635, which is commonly associated with the related 1 HP single-phase 3450 RPM motor application. Do not confuse it with MX001640 or MX001641, which are 1 HP 1725 RPM motors. Horsepower alone is not enough to select the correct replacement motor.
Similar Parts That Are Not Automatically Interchangeable
- HySecurity MX001636 - related base motor part number, commonly listed as 1 HP, 3-phase, 3450 RPM, 208-230/460VAC; verify package relationship before substituting.
- MX001635-P-MOTOR-ASSY-1-HP-1PH-3450RPM_p_11420.html">HySecurity MX001635 - related 1 HP single-phase 3450 RPM motor; not the same as MX001636-P.
- mx001641-1-hp-three-phase-1725-rpm-electric-motor.html">HySecurity MX001641 - 1 HP, three-phase, 1725 RPM motor; same horsepower and phase but different RPM.
- mx001640-1-hp-single-phase-1725-rpm-electric-motor.html">HySecurity MX001640 - 1 HP, single-phase, 1725 RPM motor; different phase and RPM.
- mx001634-3-4-hp-3-phase-electric-motor-strongarm.html">HySecurity MX001634 - 3/4 HP, three-phase, 3450 RPM motor; different horsepower.
- MX001910-LEESON-34-HP-1PH-ASSY-KIT_p_11444.html">HySecurity MX001910 - 3/4 HP, single-phase, 3450 RPM motor; different horsepower and phase.
- mx001637-p-2hp-single-phase-motor-assembly-3450rpm.html">HySecurity MX001637 and MX001638 - 2 HP motor references used in some HydraSupply XL applications; not the same horsepower or application.
- Motor couplers, contactors, overloads, pump parts, valve coils, and hydraulic assemblies - related service items, but not the motor assembly itself.
Not Intended For
- Single-phase motor replacement where MX001635 or another single-phase motor is specified.
- 24VDC motor replacement.
- 1725 RPM motor applications unless the parts diagram specifically calls for MX001636-P.
- Hydraulic pump pack replacement.
- Motor coupler replacement.
- Hydraulic valve, hose, fitting, manifold, or cylinder replacement.
- Limit switch, reset switch, sensor, controller, contactor, overload, or circuit board replacement.
- Repairs where the actual problem is incorrect voltage, phase loss, phase imbalance, pump drag, gate binding, or hydraulic overload.
Features & Specifications
| Feature / Specification | Details |
| Manufacturer | HySecurity / Nice HySecurity |
| Part Number | MX001636-P |
| Related Base Part Number | MX001636, verify package relationship before substituting |
| Product Type | Three-phase AC motor assembly |
| Horsepower | 1 HP |
| Phase | Three-phase / 3PH / 3 |
| Frequency | 60Hz where specified by motor label and parts diagram |
| RPM | 3450 RPM |
| Voltage | Related base listing commonly shows 208-230/460VAC; confirm motor label and operator wiring |
| Common Description | Motor assembly, 1 HP, 3PH, 3450 RPM |
| Possible Operator Families | Select SlideDriver, SwingRiser, and WedgeSmart applications where listed by parts diagram |
| Package Contents | Verify current package contents before ordering; coupler, contactor, overload, wiring, and mounting hardware may be separate unless stated |
Also Known As / Related Part Numbers
- MX001636-P
- MX001636P
- HySecurity MX001636-P
- Nice HySecurity MX001636-P
- HYS-MX001636-P
- HYS-MX001636P
- HySecurity motor assy, 1 HP, 3PH, 3450RPM
- HySecurity motor assembly, 1 HP, 3-phase, 3450 RPM
- HySecurity 1 HP 3-phase 3450 RPM motor assembly
- HySecurity 208-230/460VAC 1 HP 3-phase motor, where listed as MX001636
- MX001636 - related base motor number; verify package relationship before substituting
- HYS-MX001636 - related distributor SKU format; verify before substituting
- MX001635 - related 1 HP single-phase 3450 RPM motor; not the same part
- MX001641 - related 1 HP three-phase 1725 RPM motor; not the same part
- MX001640 - related 1 HP single-phase 1725 RPM motor; not the same part
Related Parts and Accessories
The correct related parts depend on the operator model, motor-to-pump arrangement, incoming electrical service, wiring, and the cause of the original motor failure. Inspect the surrounding drive and electrical components before ordering only the motor assembly.
- Motor coupling hardware - verify the correct coupler by operator model and pump shaft arrangement.
- Contactor and overload components - related electrical switching and protection parts, not the motor assembly.
- Motor wiring and terminal hardware - confirm proper three-phase wiring for the selected voltage.
- Hydraulic pump assembly - separate from the motor and should be inspected for drag or binding.
- Hydraulic fluid, hoses, fittings, and valves - inspect if the motor failed under hydraulic load.
- Phase monitoring or electrical protection components - verify if the operator installation uses them.
Technician Note
Before replacing MX001636-P, verify that the motor is actually failed. A three-phase motor complaint can be caused by incorrect voltage, phase loss, phase imbalance, bad contactor, tripped overload, loose wiring, damaged coupling, pump drag, hydraulic pressure issues, or gate binding. If the motor failed from overload, incorrect voltage, or a mechanical/hydraulic problem, the replacement may fail again unless the root cause is corrected.
Compare the original motor label to the replacement specification before ordering. Pay close attention to voltage, phase, RPM, horsepower, shaft/coupler arrangement, mounting style, rotation, and wiring. A 1 HP motor that looks physically similar may still be wrong if the phase, RPM, voltage, frame, shaft, or mounting differs.
Before Ordering, Confirm
- The required part number is MX001636-P.
- The original motor is 1 HP, three-phase, and 3450 RPM.
- The operator electrical service matches the required three-phase voltage configuration.
- The operator model and serial number match the parts diagram being used.
- The replacement is not being confused with MX001635, MX001640, MX001641, MX001634, or another similar motor.
- The shaft, motor coupling, mounting, rotation, and wiring arrangement match the original installation.
- The motor failure was not caused by phase loss, incorrect voltage, pump drag, hydraulic overload, gate binding, or failed electrical protection.
- The package contents include what is needed for reassembly, or that coupler-related hardware and electrical components are ordered separately if required.
Installation and Service Notes
- Disconnect and lock out power before servicing the motor or operator electrical system.
- Do not work on energized three-phase motor wiring or live operator controls.
- Confirm the correct voltage tap and wiring configuration before applying power to the replacement motor.
- Verify phase rotation and motor direction before returning the operator to normal service.
- Inspect the motor coupling and pump shaft before installing the new motor assembly.
- Do not force an incorrect shaft, coupling, or mounting arrangement.
- After service, verify proper motor rotation, smooth gate movement, correct hydraulic performance, overload protection, and all required safety devices.
Professional Advisory
Motor replacement on a HySecurity gate operator should be performed by a qualified gate technician or qualified electrical professional when the repair involves three-phase AC line voltage, motor rotation, electrical protection, motor coupling alignment, hydraulic pump load, heavy gate movement, or safety-critical operator performance. Do not bypass fuses, overloads, controller protections, limit controls, inherent entrapment sensors, photo eyes, gate edges, or other safety devices to test a motor.
Product Questions & Answers
What is HySecurity MX001636-P?
HySecurity MX001636-P is a 1 HP three-phase AC motor assembly rated at 3450 RPM for select HySecurity gate operator applications. It should be used only where the parts diagram or original motor label confirms this part number.
What voltage is the MX001636-P motor assembly?
Related base part MX001636 is commonly listed with a 208-230/460VAC three-phase voltage rating. Confirm the voltage on the motor label and operator wiring before installation.
Is MX001636-P single-phase or three-phase?
MX001636-P is a three-phase motor assembly. It should not be confused with similar single-phase motors, including MX001635.
Is MX001636-P the same as MX001636?
MX001636 appears to be the related base motor number, while MX001636-P may indicate a packaged motor assembly or service package. Verify the current package contents and parts diagram before substituting one for the other.
Is MX001636-P the same as MX001641?
No. MX001636-P is a 1 HP, three-phase, 3450 RPM motor assembly, while MX001641 is a 1 HP, three-phase, 1725 RPM motor. The RPM is different, so they should not be treated as interchangeable.
Can MX001636-P be used on SlideDriver operators?
Related MX001636 listings commonly reference SlideDriver 15 and 40 SS/E three-phase applications. Use MX001636-P only where the SlideDriver parts diagram confirms this motor assembly or approved related part number.
What should be checked before replacing MX001636-P?
Before replacing the motor assembly, check incoming three-phase voltage, phase loss, phase imbalance, wiring, contactor and overload operation, motor coupling, pump load, hydraulic pressure, and gate movement. These issues can mimic a failed motor or damage a new motor.